• Title/Summary/Keyword: Pocket implant

Search Result 252, Processing Time 0.019 seconds

Use of Acellular Biologic Matrix Envelope for Cardiac Implantable Electronic Device Placement to Correct Migration into Submuscular Breast Implant Pocket

  • Peyton Terry;Kenneth Bilchick;Chris A. Campbell
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.156-159
    • /
    • 2023
  • Breast implants whether used for cosmetic or reconstructive purposes can be placed in pockets either above or below the pectoralis major muscle, depending on clinical circumstances such as subcutaneous tissue volume, history of radiation, and patient preference. Likewise, cardiac implantable electronic devices (CIEDs) can be placed above or below the pectoralis major muscle. When a patient has both devices, knowledge of the pocket location is important for procedural planning and for durability of device placement and performance. Here, we report a patient who previously failed subcutaneous CIED placement due to incision manipulation with prior threatened device exposure requiring plane change to subpectoral pocket. Her course was complicated by submuscular migration of the CIED into her breast implant periprosthetic pocket. With subcutaneous plane change being inadvisable due to patient noncompliance, soft tissue support of subpectoral CIED placement with an acellular biologic matrix (ABM) was performed. Similar to soft tissue support used for breast implants, submuscular CIED neo-pocket creation with ABM was performed with durable CIED device positioning confirmed at 9 months postprocedure.

Immediate Breast Reconstruction Placing the Breast Implant under the Pectoralis Major-Serratus Anterior Pocket without Tissue Expansion (조직확장술을 거치지 않고 유방보형물을 대흉근-전거근 포켓에 삽입한 즉시 유방재건술)

  • Kim, Hoon;Eom, Jin Sub;Ahn, Sei Hyun;Son, Byung Ho;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.622-627
    • /
    • 2007
  • Purpose: Although the autogenous tissue transfer has been the mainstay of the breast reconstruction, concern for the donor site morbidity can lead to the superseded method using tissue expander with implant or permanent expander-implant. However, the additional procedure of tissue expansion possibly cause discomfort and raise the cost. We tried to verify the efficacy of using the saline-filled breast implant by itself for the safe and convenient immediate breast reconstruction modality if the patients have small, round and non-ptotic breasts and the sufficient breast skin can be saved with mastectomy. Methods: From July 2002 to July 2005, 29 breasts of 26 patients were restored only with the saline-filled breast implant immediately after the skin sparing or nipple-areolar skin sparing mastectomy in Asan Medical Center. A pocket with pectoralis major and serratus anterior muscle was created and the implant was covered with this muscle pocket. Simultaneous contralateral augmentation was performed in patients whose mastectomy specimen weighed less than 100g. Results: Using only the saline-filled breast implant resulted in the successful reconstruction with few complications including partial necrosis of nipple areolar skin (five cases, 17.2%), capsular contracture (three cases, 10.3%), hematoma (one case, 3.4%), depigmentation of areolar skin (one case, 3.4%), hypertrophic scar (one case, 3.4%), which were all healed by conservative management. There were no significant complications such as implant exposure and subsequent removal. Conclusion: Immediate breast reconstruction only with the saline-filled breast implant can be a satisfactory alternative option for the patients whose breast is small, round and non-ptotic, especially when the nipple-areolar skin of the breast is preserved in the mastectomy.

Two-Stage Latissimus Dorsi Flap with Implant for Unilateral Breast Reconstruction: Getting the Size Right

  • Feng, Jiajun;Pardoe, Cleone I;Mota, Ashley Manuel;Chui, Christopher Hoe Kong;Tan, Bien-Keem
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.197-203
    • /
    • 2016
  • Background The aim of unilateral breast reconstruction after mastectomy is to craft a natural-looking breast with symmetry. The latissimus dorsi (LD) flap with implant is an established technique for this purpose. However, it is challenging to obtain adequate volume and satisfactory aesthetic results using a one-stage operation when considering factors such as muscle atrophy, wound dehiscence and excessive scarring. The two-stage reconstruction addresses these difficulties by using a tissue expander to gradually enlarge the skin pocket which eventually holds an appropriately sized implant. Methods We analyzed nine patients who underwent unilateral two-stage LD reconstruction. In the first stage, an expander was placed along with the LD flap to reconstruct the mastectomy defect, followed by gradual tissue expansion to achieve overexpansion of the skin pocket. The final implant volume was determined by measuring the residual expander volume after aspirating the excess saline. Finally, the expander was replaced with the chosen implant. Results The average volume of tissue expansion was 460 mL. The resultant expansion allowed an implant ranging in volume from 255 to 420 mL to be placed alongside the LD muscle. Seven patients scored less than six on the relative breast retraction assessment formula for breast symmetry, indicating excellent breast symmetry. The remaining two patients scored between six and eight, indicating good symmetry. Conclusions This approach allows the size of the eventual implant to be estimated after the skin pocket has healed completely and the LD muscle has undergone natural atrophy. Optimal reconstruction results were achieved using this approach.

Rupture and Intrapleural Migration of a Cohesive Silicone Gel Implant after Augmentation Mammoplasty: A Case Report (코헤시브 실리콘 젤 유방삽입물을 이용한 유방확대술 후 발생한 유방삽입물의 흉강내로의 이탈 및 파열 증례보고)

  • Lee, Jun-Yong;Kim, Han-Koo;Kim, Woo-Seob;Park, Bo-Young;Bae, Tae-Hui;Choe, Ju-Won
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.323-325
    • /
    • 2011
  • Purpose: Breast implant ruptures and displacement are problematic complications after augmentation mammoplasty. The authors report a patient whose cohesive silicone gel implant ruptured and migrated into the pleural cavity after augmentation mammoplasty. Methods: A 23-year-old female had received augmentation mammoplasty at a local clinic a week before visiting our hospital. When the patient's doctor performed a breast massage on the sixth postoperative day, the left breast became flattened. The doctor suspected a breast implant rupture and performed revision surgery. The implant, however, was not found in the submuscular pocket and no definite chest wall defect was found in the operative field. The doctor suspected implant migration into the pleural cavity, and after inserting a new breast implant, the doctor referred the patient to our hospital for further evaluation. The patient's vital signs were stable and she showed no specific symptoms except mild, intermittent pain in the left chest. A CT scan revealed the ruptured implant in the left pleural cavity and passive atelectasis. Results: The intrapleurally migrated ruptured implant was removed by video-assisted thoracic surgery (VATS). There were no adhesions but there was mild inflammation of the pleura. No definite laceration of the pleura was found. The patient was discharged on the first day after the operation without any complications. Conclusion: Surgeons should be aware that breast implants can rupture anytime and the injury to the chest wall, which may displace the breast implant into the pleural cavity, can happen during submuscular pocket dissection and implant insertion.

High Speed Sram Transistor Performance 향상에 관한 연구

  • NamGung, Hyeon;Hwang, Deok-Seong;Jang, Hyeong-Sun;Park, Sun-Byeong;Hong, Sun-Hyeok;Kim, Sang-Jong;Kim, Seok-Gyu;Kim, Gi-Jun;No, Yong-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.97-98
    • /
    • 2006
  • For high performance transistor in the 0.14um generation, high speed sram is using a weak region of SCE(Short Channel Effect). It causes serious SCE problem (Vth Roll-Off and Punch-Through etc). This paper shows improvement of Vth roll-off and Ion/Ioff characteristics through high concentration Pocket implant, LDD(Light Dopped Dram) and low energy Implant to reduce S/D Extension resistance. We achieve stabilized Vth and Improved transistor Ion/Ioff performance of 10%.

  • PDF

Correction of the Dorsal Contour Deformity Caused by Scoliosis with Silicone Implant (실리콘 보형물을 이용한 척추측만증 배부 윤곽변형 교정수술)

  • Park, Ji Ung;Cho, Sang Hun;Shin, Jong In;Kim, Chang Yeon
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.792-795
    • /
    • 2007
  • Purpose: Scoliosis is a multifactorial disorder caused by genetic, biochemical, developmental, neuromuscular factors and causes complex deformities which include skeletal deformity, pain, cardiovascular dysfunction, motor function disorder. Until now, the treatment of scoliosis have been focused on orthopedic correction, preservation of cardiopulmonary and neurologic function. But recently, as aesthetic demands increases, the needs for the correction or improvement of the trunk and extremity contour does. So, the correction of soft tissue contour deformity can be a new concept for the treatment of scoliosis. Methods: We corrected a deformed contour with prefabricated silicone implant in a scoliosis patient who had been operated for orthopedic correction previously. Submuscular pocket was made under trapezius and latissimus dorsi muscle. Silicone implant was placed in the pocket and fixed to thoracolumbar fascia with sutures. Results: We had a satisfactory results for the correction of contour deformity. There was no significant complication. Conclusion: Silicone implant is a new trial for the correction of scoliosis contour deformity. This method is simple, safe and brings on satisfactory results.

Advanced peri-implantitis cases with radical surgical treatment

  • McCrea, Shane J.J.
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose: Peri-implantitis, a clinical term describing the inflammatory process that affects the soft and hard tissues around an osseointegrated implant, may lead to peri-implant pocket formation and loss of supporting bone. However, this imprecise definition has resulted in a wide variation of the reported prevalence; ${\geq}10%$ of implants and 20% of patients over a 5- to 10-year period after implantation has been reported. The individual reporting of bone loss, bleeding on probing, pocket probing depth and inconsistent recording of results has led to this variation in the prevalence. Thus, a specific definition of peri-implantitis is needed. This paper describes the vast variation existing in the definition of peri-implantitis and suggests a logical way to record the degree and prevalence of the condition. The evaluation of bone loss must be made within the concept of natural physiological bony remodelling according to the initial peri-implant hard and soft tissue damage and actual definitive load of the implant. Therefore, the reason for bone loss must be determined as either a result of the individual osseous remodelling process or a response to infection. Methods: The most current Papers and Consensus of Opinion describing peri-implantitis are presented to illustrate the dilemma that periodontologists and implant surgeons are faced with when diagnosing the degree of the disease process and the necessary treatment regime that will be required. Results: The treatment of peri-implantitis should be determined by its severity. A case of advanced peri-implantitis is at risk of extreme implant exposure that results in a loss of soft tissue morphology and keratinized gingival tissue. Conclusions: Loss of bone at the implant surface may lead to loss of bone at any adjacent natural teeth or implants. Thus, if early detection of peri-implantitis has not occurred and the disease process progresses to advanced peri-implantitis, the compromised hard and soft tissues will require extensive, skill-sensitive regenerative procedures, including implantotomy, established periodontal regenerative techniques and alternative osteotomy sites.

FACTORS AFFECTING WOMEN'S OUT-OF-POCKET COST : AN APPLICATION OF THE ANDERSEN-NEWMAN MODEL (앤더슨-뉴만 모형을 이용한 여성의 직접구강진료비 지출에 관한 연구)

  • Lee, Heung-Soo;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.689-699
    • /
    • 1996
  • The purpose of this research is to determine elements affecting the out-of-pocket cost of woman. The sample consisted of 1907 women living Iksan city. The survey was conducted by means of questionnaires. The model used in the analysis of out-of-pocket cost was the Andersen-Newman model, while the analysis techniques used were stepwise multiple regression and path analysis. The number of independent variables used in the analysis was 28 in total, ie 19 predisposing components, 6 enabling components, and 3 need components. In this study, the amount of variance by the model was 17 percent. Number of restricted activity days caused by oral disease, perceived susceptibility of dental disease, having a regular dental care, dental treatment costs, education level and income were found to have significant major effects on out-of-pocket cost. Number of restricted activity days caused by oral disease was the most important variable affecting out-of-pocket cost of woman. Also out-of-pocket cost shows larger effect due to enabling components than frequency of dental utilization.

  • PDF

RELATIONSHIP BETWEEN PROBING POCKET DEPTH AND TRYPSIN-LIKE ACTIVITY IN SUBGINGIVAL PLAQUE (치주낭 탐침깊이와 치은연하치태내 Trypsin-like activity와의 관계)

  • Park, Jea-Han;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.442-453
    • /
    • 1993
  • In order to determine the relationship between probing pocket depth and trypsin-like activity in subgingival plaque, probing pocket depth and loss of attachment were measured by Michigan-O probe on mandibular incisors of 30 patients with adult periodontitis. And the trypsin-like activity of Treponema denticola, Porphyromonas gingivalis, and Bacteroides forsythus was evaluated by the hydrolysis of N-Benzoyl-DL-Arginine-2-Naphthyla-mide (BANA) using PerioScan reagent cards(Oral-B Laboratories, Redwood City, CA). The obtained data were statistically analyzed by Microstat program. The results were as follows. 1. The number of teeth showing negative trypsin-like activity was more in shallow periodontal pocket groups, but the number of teeth showing positive trypsin-like activity was more in deep periodontal pocket groups. 2. There was a significant positive correlation between probing pocket depth and trypsin-like activity in subgingival plaque(y=0.413X - 0.955, r = 0.7024, p<0.001). 3. There was no consistent relationship between loss of attachment and trypsin-like activity in subgingival plaque(p>0.01).

  • PDF