• Title/Summary/Keyword: PoF

Search Result 268, Processing Time 0.028 seconds

Investigation on Formation of Nanotube Titanium Oxide Film by Anodizing on Titanium in NaF Electrolytes (NaF 전해용액을 이용한 양극산화에 의한 타이타늄 표면의 나노튜브구조의 형성에 관한 연구)

  • Lim, Hyun-Pil;Park, Nam-Soon;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.183-190
    • /
    • 2009
  • The aim of this study is to find the condition of forming the favorable nanotubes by anodizing with NaF and $H_3PO_4$. Machined Ti discs were used for anode, and Platinum net was used for cathode. For electrolyte, $H_3PO_4$ and NaF solution were mixed. We controlled voltage, electrolyte concentration, anodizing time and formed nanotubes on Ti discs. After that, these were washed with distilled water for 24 hours and dried in the $40^{\circ}C$ oven for 24 hours. The surface structure of specimens were analyzed. The results were as follows : At 0.5 wt % NaF, according as increasing voltage and anodizing time, early state of nucleating pores were generated. At 1.0 wt % NaF, 20 V, 20 & 25 min, well-formed nanotubes were observed. At 1.0 wt % NaF, 30 V, structure of nanotube became bigger and interconnected. At 2.0 wt % NaF, no nanotubes were formed and it was unrelated with voltage and time. At 1.0 wt % NaF, 20 V, 20 - 25 min, well-ordered nanotubes were generated on Ti discs. For the formation of favorable nanotubes, it is considered that proper parameters such as electrolyte concentration, voltage, anodizing time are necessary according to the kind of electrolytes.

Thermal and Electrical Properties of Poly(vinylidene fluoride-hexafluoropropylener)-Based Proton Conducting Gel-Electrolytes (Poly(vinylidene fluoride-hexafluoropropylene)계 양성자 전도성 겔-전해질의 열적, 전기적 특성)

  • 최병구;박상희
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.179-184
    • /
    • 2002
  • Polymer electrolyte films consisting of poly (vinylidenefluoride-hexafluoro-propylene) (PVdF-HFP) $H_3PO_4$and a mixture of ethylene carbonate(EC), $\gamma$-butyrolactone(BL) and dimethylcarbonate (DMC) were examined in order to obtain the best compromise between high protonic conductivity, homogeniety and dimensional stability. Measurements of differential scanning calorimetry and ionic conductivity have been carried out for various compositions. The highest proton conductivity of 7.3 $\times$$10^{-3}Sm^{-1}$ at $30^{\circ}C$ were obtained for a film of 30(PVdF-HFP) + 50EC/DMC + 20H$_3$PO$_4$. From the thermal study, it has been found that the PVdF-HFP gels are stable up to $80^{\circ}C$, and the $H_3PO_4$ enhances the miscibility of the polymer and the solvent by interacting sensitively with polymer segments.

Temperature Dependent Optical Performance of the NaSr(PO3)3:Eu2+ Blue Phosphors (NaSr(PO3)3:Eu2+ 청색 형광체의 온도 의존적 형광 특성)

  • Yoon, Chang yong;Lee, Sang ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.391-399
    • /
    • 2021
  • Eu2+ doped polyphosphate NaSr(PO3)3 blue-emitting phosphors were synthesized by the conventional solid state method in a reductive atmosphere. The phase formation of NaSr(PO3)3 phosphors were characterized by using the X-ray powder diffraction (XRD) measurement. The photoluminescence emission and excitation spectra of the NaSr(PO3)3:Eu2+ phosphor, and decay curves were measured. Under the near-UV excitation, the phosphor exhibits a band emission around 420 nm assigned to the 4f65d→f7(8S7/2) transition of Eu2+. The temperature dependent emission spectra and decay curves were measured to elevate the thermal properties of the Eu2+ doped phosphors. The as-prepared NaSr(PO3)3:Eu2+ phosphors show a strong temperature dependent performance, which can serve as a promising temperature sensor.

Synthesis of wagnerite and its analogues for ceramic pigments (ll) (도자기 유약용 Wagnerite의 합성(II))

  • Yong- Sun Chung;Keun Ho Auh
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.4
    • /
    • pp.648-657
    • /
    • 1997
  • In order to investigate the polymorphism of wagnerite, the single phase of$Mg_3(PO_4)_2$ was synthesized by heating the stoichiometric mixture of $Mg_3(PO_4)_2$ and $MgF_2$ in a sealed platinum tube at $1040^{\circ}C$ (or 3 hours, One reversible inversion was detected at $1255^{\circ}C$ and the thermal decomposition was not observed until it reached the melting point. As a result, wagnerite is thermally stable enough to be used as pigments for glazes and plastics if substituted with divalent metal ions. The contractions of d-values in $Zn_4P_2O_8F_2$ and $Zn_3MgP_2O_8F_2$ phases were observed by the substitution with metal ions which resulted in intense purple, gold and green colors. Among the several attempts of charge - coupled sub-stitution, only $A^{1+}A_3^{2+}X^{5+}X^{6+}O_8_F2$ compositions were successful to synthesize the wagnerite phase.

  • PDF

A study on Application of Probabilistic Fatigue Life Prediction for Aircraft Structures using the PoF based on Bayesian Approach (베이지안 기반의 파손확률을 이용한 항공기 구조물 확률론적 피로수명 예측 응용에 관한 연구)

  • Kim, Keun Won;Shin, Dae Han;Choi, Joo-Ho;Shin, Ki-Su
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.631-638
    • /
    • 2013
  • The probabilistic fatigue life analysis is one of the common methods to account the uncertainty of parameters on the structural failure. Frequently, the Bayesian approach has been demonstrated as a proper method to show the uncertainty of parameters. In this work, the application of probabilistic fatigue life prediction method for the aircraft structure was studied. This effort was conducted by using the PoF(Probability of Failure) based on Bayesian approach. Furthermore, numerical example was carried out to confirm the validation of the suggested approach. In conclusion, it was shown that the Bayesian approach can calculate the probabilistic fatigue lives and the quantitative value of PoF effectively for the aircraft structural component. Moreover the calculated probabilistic fatigue lives can be utilized to determine the optimized inspection period of aircraft structures.

Reliability Design Analysis for Underwater Buriend PBA Based on PoF (고장물리 기반 수중 매설형 PBA에 대한 신뢰성 설계 연구)

  • Kim, Ji-Young;Lee, Ki-Won;Yoon, Hong-Woo;Lee, Seung-Jin;Heo, Jun-Ki;Kwon, Hyeong-Ahn
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.280-288
    • /
    • 2017
  • Purpose: PBA buried in underwater requires high reliability because of its mission critical characteristic and harsh operational environment during its life cycle. Therefore, various reliability improvement activities are necessary. The defect on PBA manufacturing process have been studied, as a result, many activities and standards have been presented. However, there are less studies regarding failure pattern on physical features based on design. In this paper, we studied a possible failure patten based on physical features that is related with manufacturing process of PBA. And reliability improvement design based on PoF (Physical of Failure) were intruduced in this paper. Methods: A reliability prediction simulation were performed on the components A and B of the H system using Sherlock Software which is a PoF commercial tool from DFR solution. Solder fatigue and PTH fatigue analysis based on thermal cycling profiles and random vibration was analyzed on three earthquake response spectrum. Result: It was validated that life time and reliability improvement design through solder fatigue and PTH fatigue analysis in case of component. For compoenet B, random vibration fatigue was additionally analyzed and validated reliability for earthquakes profile. Conclusion: In design stage prior to manufacturing, PoF can be analyzed, and it is possible to make a reliability improvement/validated design using design data. This study can be applied in every design step and contribute to make more stable development product.

Staticposture stability evaluation of female elderly using stability evaluation device (균형능력 평가 장치를 이용한 여성노인의 정적자세안정성 평가)

  • Kim, Tae-Hyung;Yi, Jae-Hoon;Oh, Seong-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5518-5524
    • /
    • 2011
  • The purpose of this study is to investigate the change of balance ability on aging by measuring balance ability of elderly females whose age is over 65. The subjects are ten elderly women (the mean age: 71.9) able to walk without assistants, the assistant equipments and drug dependence and ten young healthy women (the mean age: 23.2). We measured stability index (ST), Fourier index (F), weight distribution (WD), weight distribution index (WDI), synchronization index (SI) and fall index (FI) by using Tetrax (Tetra-ataxiometric Posturography). In result, STs and Fs at the low frequency region (F1) represented the significant difference between two groups at all postures with PO (pillow with eye open) exception (p<.01). Fs at the other frequency regions (F2~F8) represented the significant difference between two groups (p<.05). WDI of the elderly women represented the higher values than the young women at all postures but there are the significant difference at PO and PC (pillow with eye closed) only. These results may be due to age-related ability decline of somatesthesia, vestibular organ, central nervous system.

Modeling the electric transport of HCl and H3PO4 mixture through anion-exchange membranes

  • Koter, Stanislaw;Kultys, Monika;Gilewicz-Lukasik, Barbara
    • Membrane and Water Treatment
    • /
    • v.2 no.3
    • /
    • pp.187-205
    • /
    • 2011
  • The electric transport of the mixture of hydrochloric and phosphoric acids through strong base (Neosepta ACM) and weak base (Selemion AAV) anion-exchange membranes was investigated. The instantaneous efficiency of HCl removal from the cathode solution, $CE_{Cl}$, with and without $H_3PO_4$ was determined. It was found that $CE_{Cl}$ was 0.8-0.9 if the number of moles of elementary charge passed through the system, $n_F$, did not exceed ca. 80% of the initial number of HCl moles in the cathode solution, $n_{Cl,ca,0}$. The retention efficiency of $H_3PO_4$ in that range was close to one. The transport of acid mixtures was satisfactorily described by a model based on the extended Nernst-Planck and Donnan equations for $n_F$ not exceeding $n_{Cl,ca,0}$. Among the tested model parameters, most important were: concentration of fixed charges, the porosity-tortuosity coefficient, and the partition coefficient of an undissociated form of $H_3PO_4$. For the both membranes, the obtained optimal values of fixed charge concentration, $\bar{c}_m$, were up to 40% lower than the literature values of $\bar{c}_m$ obtained from the equilibrium measurements. Regarding the $H_3PO_4$ equilibria, it was sufficient to consider $H_3PO_4$ as a monoprotic acid.

Comparative Study and Electrochemical Properties of LiFePO4F Synthesized by Different Routes

  • Huang, Bin;Liu, Suqin;Li, Hongliang;Zhuang, Shuxin;Fang, Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2315-2319
    • /
    • 2012
  • To improve the performance of $LiFePO_4F$, a novel sol-gel process is developed. For comparison, ceramic process is also implemented. From X-ray diffraction results we know that each sample adopts a triclinic $P{\bar{1}}$ space group, and they are isostructural with amblygonite and tavorite. The scanning electron microscope images show that the homogeneous grains with the dimension of 300-500 nm is obtained by the sol-gel process; meanwhile the sample particles obtained by ceramic process are as big as 1000-3000 nm. By galvanostatic tests and at electrochemical impedance spectroscopy method, the sample obtained by sol-gel process presents better electrochemical properties than the one obtained by ceramic process.

Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

  • Oh, Suseok;Ahn, Jaemyung;Nam, Ki-Uk;Paeng, Jun-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R: Or.R - Or.L - Po.R; 2) FH plane L: Or.R - Or.L - Po.L; 3) F. Ovale plane R: Rt.F.Ovale - Lt.F.Ovale - Or.R; 4) F. Ovale plane L: Rt.F.Ovale - Lt.F.Ovale - Or.L; 5) FZS plane R: Rt.FZS - Lt.FZS - Po.R; 6) FZS plane R: Rt.FZS - Lt.FZS - Po.L, and; 7) FZS line: Rt.FZS - Lt.FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.