• Title/Summary/Keyword: Pneumatic Test

Search Result 206, Processing Time 0.027 seconds

Liquid Oxygen Filling System of Propulsion System Test Complex(PSTC) for KSLV-II (한국형발사체 추진기관시스템 시험설비(PSTC) 산화제 공급 시스템)

  • Lee, Janghwan;Choi, Bongsu;Kim, Yongwook;Cho, Kiejoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1184-1187
    • /
    • 2017
  • The space launch vehicle needs the verification of each stage's propulsion system. The Propulsion System Test Complex(PSTC) is constructed for developing KSLV-II in the Naro space center. Hydraulic and pneumatic system of PSTC should supply propellants and various gases to propulsion system module according to required condition. This paper introduces liquid oxygen filling system of PSTC.

  • PDF

A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

Identification of Optimal Control Parameters for a Pneumatic Active Engine Mount System (공압식 능동형 엔진마운트시스템의 최적 제어매개변수 식별)

  • Kim, Il-Jo;Lee, Jae-Cheon;Choi, Jae-Yong;Kim, Jeong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.30-37
    • /
    • 2012
  • Pneumatic Active Engine Mount(PAEM) with open-loop control system has been developed to reduce the transmission of the idle-shake vibration induced by engine effectively and economically. A solenoid valve installed between PAEM and vacuum tank is on-off switched by the Pulse Width Modulate(PWM) control signal to decrease the dynamic stiffness of the engine mount. This paper presents the methodology to identify the optimal values of control parameters of a PAEM, i.e, turn-on timing and duty ratio of PWM signal for 6 different idle driving conditions. A scanning algorithm was first applied to the vehicle test to obtain the approximate optimal control parameters minimizing the vibration at front seat rail and at steering wheel. Then the PAEM system identification was fulfilled to find accurate optimal control parameters by using multi-layer neural networks of Levenberg-Marquardt algorithm with vehicle test data.

Pneumatic Test Assessment of Pulse Separation Device for Multi-Pulse Rocket Motor (다중펄스 로켓모타 적용 펄스분리장치의 공압시험평가)

  • Lee, Dong-Won;Lee, Won-Bok;Kang, Seong-Yeop;Lee, Jong-Won;Chang, Hong-Been
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.101-104
    • /
    • 2010
  • A bulkhead-type pulse separation device has been developed for the multi-pulse rocket motor. The design parameters of the pulse separation device were the shape of the rupture disc slit, welding conditions, and the implementation of the seal disc. The pneumatic tests of the fabricated pulse separation devices showed that the rupture pressure increased as the quantity of the rupture disc slit and welding strength increased and the seal disc was implemented.

  • PDF

Design of A Data Transmission System for Pneumatic System Control (공기압 시스템 제어를 위한 데이터 전송시스템 설계)

  • 홍춘표;김동수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.413-418
    • /
    • 2000
  • For Pneumatic system control, we need a data transmission system with high speed and high realibility for information interchange between main computer and solenoid valves and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition we developed a communication protocol for construction of RS-485 based multidrop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is possible up to 1,000m without using repeater. In addition, the system developed in this research is proved to be used easily for extension of a communication network because of its module structure.

  • PDF

A Study on Dynamic Characteristic of Robot Cables (로봇 케이블의 동적 특성에 관한 연구)

  • Kim, Jin Kyu;Kim, Jae Bong;Kang, Dae Sun;Choi, Woong Sub;Kim, Moon Young;Lee, Sang Beom;Yim, Hong Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.495-499
    • /
    • 2014
  • In this study, the finite element modeling for the signal cable and pneumatic hose of the industrial robot is developed. The modulus of elasticity of signal cable and pneumatic hose is predicted by deflection test. Finite element model for the signal cable and pneumatic hose is developed by using the modulus of elasticity obtained from the tests. The developed finite element model is estimated through the vibration analysis. This study shows that the developed finite element model can be effectively utilized in the dynamic analysis.

  • PDF

The Development of a Flood Protection System for Pad Transformers Using Pneumatic Pressure in Areas Prone to Floods

  • Kim, Gi-Hyun;Lee, Jae-Yong;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown areas and low-lying shores by torrential rain, typhoons and tsunamis. It has, in turn, caused replacement, social and economic costs for blackouts. For activity management regarding flood damage we produced a flood protection system which using the Pad transformer as a basic frame and is developed using pneumatic pressure. We tested safety concerns including insulation resistance and current leakage first for water tank flooding and, second, by an empirical test through supplying 22.9[kV]. We estimate that costs associated with flooding and power failure can be diminished by these advances toward creating a more reliable system.

Accelerating CFD-DEM simulation of dilute pneumatic conveying with bends

  • Du, Jun;Hu, Guoming;Fang, Ziqiang;Gui, Wenjie
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.84-93
    • /
    • 2015
  • The computational cost is expensive for CFD-DEM simulation, a larger time step and a simplified CFD-DEM model can be used to accelerate the simulation. The relationship between stiffness and overlap in non-linear Hertzian model is examined, and a reasonable time step is determined by a new single particle test. The simplified model is used to simulate dilute pneumatic conveying with different types of bends, and its applicability is verified by compared with the traditional model. They are good agreement in horizontal-vertical case and vertical-horizontal case, and show a significant differences in horizontal-horizontal case. But the key features of particle rope formed in different types of bends can be obtained by both models.

Design of A Data Transmission System for Pneumatic System Control

  • Hong, Chun-Pyo;Kim, Dong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.150.2-150
    • /
    • 2001
  • For pneumatic system control, we need a data transmission system with high speed and reliability for information interchange between main computer and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition, we developed a communication protocol for construction of RS-485 based multi-drop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is ...

  • PDF

Improvement of Intermittent Advancing Accuracy of Pneumatic Cylinder-Driven Roll Feeder

  • So, Jung Duck
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.3
    • /
    • pp.164-170
    • /
    • 2016
  • A proposed pneumatic cylinder-driven roll feeder and an air press were designed to be operated automatically by a PLC. The accuracy of the intermittent feed pitch of the roll feeder was evaluated by measuring lengths of cut-offs of a strip stock by a digimatic vernier caliper. At each predetermined feed pitch, the proposed roll feeder was tested 100 times by varying the feed/cut intervals as 2.0/1.5, 3.0/2.0, and 3.5/2.5 s as test sets. The lengths of the cutoffs of the strip stock ranged from 9.89-10.34, 12.1-12.65, and 15.21-15.67 mm at the predetermined 10, 12, and 15 mm feed pitch, respectively, among the total of 300 samples in each feed pitch, regardless of the feed/shear interval. Therefore, the feed/cut interval at each selected feed pitch was found to have no effect on the accuracy of the intermittent advancing of the strip stock.