• Title/Summary/Keyword: Plywood

Search Result 343, Processing Time 0.034 seconds

A Study on Laminated Furniture for Organic Form and Utility of Fullscale Model (합판 적층재 가구의 유기적 조형을 위한 실물대 모델의 효율성 연구)

  • Kim, Ji-Geon
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.5
    • /
    • pp.319-327
    • /
    • 2008
  • As art of lamination by plywood got to be generally used, it became a suitable material for expressing live curves that were not able to be expressed on wood furniture made of plank and timber, as well as, openwork deep in curved space, heavy quality of material, and changing contour line-looking wave lines with different process angles. As an alternative, it would be good to build a full scale model, since it would provide practice in form-building and it would also provide a chance to correct the form. Less material can be used and reduce the cutting process by Properly trimming models made of soft formal structure such as Styrofoam Iso-pink and adhesive Styrofoam, and separating the layers and using them on shape cutting of plywood with the same thickness. And by attaching the model veneer that was used in shape cutting of the model and using it as a cutting guide, we can reduce the error of work and successively build the planned form. Since this study is about the need of a full scale model for a laminated wood model and an efficient process, this study concentrates more on process.

  • PDF

Effect of Veneer Moisture Content on Bonding Strength of Plywood Bonded with Fatty Acid-Glycerol-pMDI Adhesive(I) - Dry Bonding Strength - (단판 함수율이 지방산·글리세롤·pMDI의 접착력에 미치는 영향(I) - 상태접착력 -)

  • Choi, Jin-Lim;Lee, Tack-Jun;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.29-35
    • /
    • 2006
  • This stud y was conducted to investigate the bonding strength of plywood bonded with fatty acid-glycerol-pMDI adhesives with equivalent ratios of 1:1:2, 1:1:3, 1:1:4, 1:1:5, and 1:1:6. With veneer moisture contents of 0%, 3%, 5%, 8% and 15%, the bonding strengths exceeded the requirement of Korean plywood standard of $7.0kgf/cm^2$ with values of $13.7kgf/cm^2$, $11.6kgf/cm^2$, $11.2kgf/cm^2$, $9.8kgf/cm^2$, and $7.4kgf/cm^2$, respectively at fatty acid-glycerol-pMDI ratio of 1:1:2. With veneer moisture content of 30%, the bonding strengths exceeded th e requirement of Korean plywood standard of $7.0kgf/cm^2$, when fatty acid-glycerol-pMDI ratios were 1:6. Finally for satisfying the Korean plywood standard, the ratio of MDI in fatty acid-glycerol-pMDI should be increased with increasing of veneer moisture content.

Studies on Distribution of Toxic Element in Commercial Plywood treated with CCA Preservative by the Soaking Method (침지법(浸漬法)에 의한 CCA처리합판(處理合板)의 약제분포(藥劑分布)에 관한 연구(硏究))

  • Ahn, Sye-Heui;Shin, Dong-So
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.35-44
    • /
    • 1985
  • The purposes of this study were, first, to investigate retention levels of toxic elements and oxide individual plies for each panel and, second, to examine disproportioning of individual toxic elements Thirty five water gum plywood panels were treated with a copper-chromium-arsenic preservative (CCA) by the soaking process as the treament time were applied. Such individual plies at a distance of 2.5cm, 7.5cm from the edge were assayed for CuO, $CrO_3$, and $As_2O_5$ on the basis of copper, chromium and arsenic content by Atomic Absorption Spectrophotometry. In these experiments, 12mm thickness plywood panels made of water gum, which were selling, were selected for the preservative treatment. Treating solutions were prepared for 10%, dilute solution of copper-chromium-arsenic preservative and then 1, 3, 6, 12 and 24 hours soaking trements in CCA preservative were applied. The results obtained are as follows: 1. The retention of total oxide in the face and back plies (1+7) retained more than the retention of total oxide in the other plies. The total oxide retention for the individual plies except the face and back plies (1+7) was showed in the following orders; cross plies (3+5), cross plies (2+6), core ply (4). 2. The retentions of total oxide increased as the increase of treatment time. The CCA treated plywood retained high levels of total oxide retention in the face and back plies (1+7). 3. All the retentions in the face and back plies (1+7) is over 5Kg/$m^3$, New Zealand Timber Preservation Standards Specification, and after 6 hours, the retentions in the cross plies (3+5) is over 4. The relative penetration of copper, chromium, and arsenic were not affected by the treatment time. The proportion of arsenic decreased in relation to both copper and chromium and the proportion of copper increased in relation to both chromium and arsenic. 5. A disproportioning of copper, chromium occurred with longer distance from edge, and with longer distance from edge the leachability resistance of CCA treated specimens decreased. After 6 hours (soaking time), the proportion of active elements at a distance of 2.5cm from the edge was consistent. And after 24 hours-soaking, the proportion of active elements at a distance of 7.5cm from the edge was consistent.

  • PDF

Comparison of Active and Passive Sampling Methods for Formaldehyde Concentrations Among Workplaces in Some Plywood Industries (능동포집과 확산포집법에 의한 일부합판제조업의 공정별 포름알데하이드 농도 비교)

  • Jang, Mi;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.17-27
    • /
    • 1996
  • This study was designed to survey exposure levels of formaldehyde among workplaces in some plywood industries and to compare three sampling methods including the impinger method(IM, NIOSH method No. 3500), the solid sorbent tube method(SS, NIOSH method No. 2541), and the passive bubbler monitor method(PB, SKC). The survey was conducted in seven particle board manufacturing factories, two resin manufacturing factories and two plywood manufacturing factories in Incheon area during the period from March 6 to April 20, 1995. The workplaces included were the hot/cold press, the roller/spreader, the soaking/drying, and the reaction/mixing areas. The results were as follows; 1. The average(GM, GSD) concentrations of formaldehyde by sampling methods were 0.11(4.43) ppm by IM, 0.27(2.03) ppm by SS, and 0.29(2.04) ppm by PB, respectively. The concentrations by 1M method were statistically very significantly lower than those of SS and PB methods, particularly at low air borne concentrations of formaldehyde (p<0.001). 2. The area average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.23(2.08) ppm from the press, 0.23(1.77) ppm from the spreader, 0.24(1.51) ppm from the soaking, and 0.46(1.96) ppm from the reaction areas, respectively. The personal average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.30(1.77) ppm from the press, 0.33(1.54) ppm from the spreader, 0.36(1.46) ppm from the soaking, and 0.84(1.19) ppm from the reaction areas, respectively. 3. No statistically significant differences of formaldehyde concentrations among workplaces except the reaction area(p<0.001) were found. 4. Formaldehyde concentrations from personal samples were higher than those of from area sam pies in all workplaces studied. But no statistically significant differences of formaldehyde concentrations both area and personal samples were found. In conclusion, this study found that although formaldehyde concentrations in some plywood industries in Incheon area were below the regulatory limit of 1 ppm, they were over the limits recommended by NIOSH and ACGIH. This study also suggests that the impinger method may underestimate true formaldehyde concentrations. It implies that there will be more workplaces not meeting current regulatory limit if either the solid sorbent or passive bubbler methods were used instead of the impinger method. It is suggested that passive monitors will be a reasonable alternative for area and personal sampling of formaldehyde if the accuracy and validity of passive monitors be verified before use.

  • PDF

A study of feasibility of using compressed wood for LNG cargo containment system (압축목재를 사용한 LNG 화물창 단열시스템의 적합성 평가에 관한 연구)

  • Kim, Jong-Hwan;Ryu, Dong-Man;Park, Seong-Bo;Noh, Byeong-Jae;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.307-313
    • /
    • 2016
  • When liquefied natural gas (LNG) is stored in a tank, it is necessary to maintain low temperature. It is very important that insulation techniques are applied to the LNG cargo because of this extreme environment. Hence, laminated wood, especially plywood, is widely used as the structural member and insulation material in LNG cargo containment systems (CCS). However, fracture of plywood has been reported recently, owing to sloshing effect. Therefore, it is necessary to increase the strength of the structural member for solving the problem. In this study, compressed wood, which is used as a support in LNG independent type B tanks, was considered as a substitute for plywood. Compression and bending tests were performed on compressed wood under ambient and cryogenic temperatures to estimate the mechanical behaviors and fracture characteristics. In addition, the direction normal to the laminates surface was considered as an experimental variable. Finally, the feasibility of using compressed wood for an LNG CCS was evaluated from the test results.

Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials (건축용 바닥재로부터의 휘발성유기화합물 방출특성)

  • Yun, Joong-Seop;Lee, Myong-Hwa;Eom, Seok-Won;Kim, Min-Young;Kim, Jong-Ho;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.973-978
    • /
    • 2010
  • The emission of volatile organic compounds (VOCs) from building materials is one of great concerns due to maintain airtight condition of a building to reduce energy consumption, and it causes the deterioration of indoor air quality. Therefore, the emission characterization of VOCs from building materials is necessary to improve indoor air quality. Emission characteristics of VOCs from a plywood flooring that is one of the most commonly used materials in an under-heating system, and from an adhesive that is generally used to stick a plywood flooring to a concrete floor were investigated using an emission chamber test in this study. It was found that the VOCs emission factor was dependent upon and proportional to indoor temperature, and the emission characteristics were closely related to the existing places and conditions of VOCs sources inside the building materials. Maximum emission factors of hexane and toluene from building materials were generally observed at the beginning, however, only that of toluene from a plywood flooring was shown after 6 hours from the beginning. It could be considered that the existing place and condition of toluene source inside a plywood flooring could influence on the VOCs emission. From this study, bake-out time more than 72 hours could be recommended before moving in to avoid the exposure to high concentration of VOCs emitted from an under-heating system.

Effects of an Inorganic Compound Added to Amino Resin Binders for Manufacture of Plywood

  • Lee, Sang-Min;Yoon, Kyoung-Dong;Park, Jong-Young;Park, Sang-Bum
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • Curing behavior and structural property of an inorganic compound added urea-formaldehyde(UF) and urea-melamine-formaldehyde(UMF) were studied. In addition, tensile strength and formaldehyde emission of plywoods made of those resin binders were studied. Curing temperature and structure were not changed, but tensile strengths of plywoods manufactured both with a UF resin and a UMF resin were decreased slightly as increased amount of inorganic compound. Formaldehyde emissions from plywoods were reduced as increased amount of inorganic compound. Wheat flour as an extender was helped to reduce of formaldehyde emission. From the result of this study it might be estimated that using appropriate amount of inorganic compound and proper resin system can be strengthened bond strength and reduced formaldehyde emission.