• Title/Summary/Keyword: Plug Length Ratio

Search Result 34, Processing Time 0.029 seconds

The Oscillation Characteristics of a Magneticfluid Plug in Curved Tube (곡관내 자성유체 PLUG의 진동특성)

  • Chun, U.H.;Lee, H.N.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.46-57
    • /
    • 1995
  • The aim of the present study is to provide fundamental informations for the development of magneticfluid actuator. To achieve the aim, oscillation characteristics of the magneticfluid plug are investigated by experiment for the various length and position of the magneticfluid plug and the frequency of magnetic field. The oscillation characteristics are obtained. Amplitude, natural frequency, phase shift and damping ratio, are compared with theoretical values. From the study, the following conclusive remarks can be made. The experimental equation for the magnetic field is obtained. The critical magneticfluid length exists and its value is about 70mm. The range of the damping ratio and fluid loss coefficient obtained by experiment are 0.1~0.2 and 30~100, respectively. Comparison between experimental and theoretical results of oscillation characteristics shows good agreement in the high frequency range. Meanwhile, in the low frequency range, there appears little discrepancies(5% in the frequency and amplitude and 10% in phase difference and damping ratio) with each other.

  • PDF

Incremental filling ratio of pipe pile groups in sandy soil

  • Fattah, Mohammed Y.;Salim, Nahla M.;Al-Gharrawi, Asaad M.B.
    • Geomechanics and Engineering
    • /
    • v.15 no.1
    • /
    • pp.695-710
    • /
    • 2018
  • Formation of a soil plug in an open-ended pile is a very important factor in determining the pile behavior both during driving and during static loading. The degree of soil plugging can be represented by the incremental filling ratio (IFR) which is defined as the change in the plug length to the change of the pile embedment length. The experimental tests carried out in this research contain 138 tests that are divided as follows: 36 tests for single pile, 36 tests for pile group ($2{\times}1$), 36 tests for pile group ($2{\times}2$) and 30 pile group ($2{\times}3$). All tubular piles were tested using the poorly graded sand from the city of Karbala in Iraq. The sand was prepared at three different densities using a raining technique. Different parameters are considered such as method of installation, relative density, removal of soil plug with respect to length of plug and pile length to diameter ratio. The soil plug is removed using a new device which is manufactured to remove the soil column inside open pipe piles group installed using driving and pressing device. The principle of soil plug removal depends on suction of sand inside the pile. It was concluded that the incremental filling ratio (IFR) is changed with the changing of soil state and method of installation. For driven pipe pile group, the average IFR for piles in loose is 18% and 19.5% for L/D=12 and 15, respectively, while the average of IFR for driven piles in dense sand is 30% and 20% for L/D=12 and L/D=15 respectively. For pressed method of pile installation, the average IFR for group is zero for loose and medium sand and about 5% for dense sand. The group capacity increases with the increase of IFR. For driven pile with length of 450 mm, the average IFR % is about 30.3% in dense sand, 14% in medium and 18.3% for loose sand while when the length of pile is 300 mm, the percentage equals to 20%, 17% and 19.5%, respectively.

Effects of pile geometry on bearing capacity of open-ended piles driven into sands

  • Kumara, Janaka J.;Kurashina, Takashi;Kikuchi, Yoshiaki
    • Geomechanics and Engineering
    • /
    • v.11 no.3
    • /
    • pp.385-400
    • /
    • 2016
  • Bearing capacity of open-ended piles depends largely on inner frictional resistance, which is influenced by the degree of soil plugging. While a fully-plugged open-ended pile produces a bearing capacity similar to a closed-ended pile, fully coring (or unplugged) pile produces a much smaller bearing capacity. In general, open-ended piles are driven under partially-plugged mode. The formation of soil plug may depend on many factors, including wall thickness at the pile tip (or inner pile diameter), sleeve height of the thickened wall at the pile tip and relative density. In this paper, we studied the effects of wall thickness at the pile base and sleeve height of the thickened wall at the pile tip on bearing capacity using laboratory model tests. The tests were conducted on a medium dense sandy ground. The model piles with different tip thicknesses and sleeve heights of thickened wall at the pile tip were tested. The results were also discussed using the incremental filling ratio and plug length ratio, which are generally used to describe the degree of soil plugging. The results showed that the bearing capacity increases with tip thickness. The bearing capacity of piles of smaller sleeve length (e.g., ${\leq}1D$; D is pile outer diameter) was found to be dependent on the sleeve length, while it is independent on the sleeve length of greater than a 1D length. We also found that the soil plug height is dependent on wall thickness at the pile base. The results on the incremental filling ratio revealed that the thinner walled piles produce higher degree of soil plugging at greater penetration depths. The results also revealed that the soil plug height is dependent on sleeve length of up to 2D length and independent beyond a 2D length. The piles of a smaller sleeve length (e.g., ${\leq}1D$) produce higher degree of soil plugging at shallow penetration depths while the piles of a larger sleeve length (e.g., ${\geq}2D$) produce higher degree of soil plugging at greater penetration depths.

Supersonic Plug Nozzle Design and Comparison to the Minimum Length Nozzle Configuration

  • Zebbiche, Toufik;Youbi, ZineEddine
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.7 no.1
    • /
    • pp.27-42
    • /
    • 2006
  • A method to design the contour and conception of a plug nozzle of arbitrary shape, but specified exit flow conditions is presented. Severals shapes can be obtained for exit Mach number by changing the specific heats ratio. The characteristics of the nozzle in terms of length, weight and pressure force exerted on the wall are compared to the Minimum Length Nozzle and found to be better. Our field of study is limited to the supersonic mode to not to have the dissociation of the molecules. The design method is based on the use of the Prandtl Meyer function of a perfect gas. The flow is not axial at the throat, which may be advantageous for many propulsion applications. The performance benefits of the plug nozzle compared to the Minimum Length Nozzle are also presented.

Effect of Day Length on the Growth of Plug Seedlings and Bulbing after Planting in Onion (Allium cepa L.) (양파 공정육묘시 일장조건이 묘 생육 및 정식 후 구 비대에 미치는 영향)

  • 서전규
    • Journal of Bio-Environment Control
    • /
    • v.12 no.2
    • /
    • pp.101-105
    • /
    • 2003
  • This experiment was conducted to find out the effect of day length on the production of high quality plug seedlings in onion (Allium cepa L.). Two cultivars, ‘Changnyongdaego’ and‘Wolryun’, were grown to seedlings in 200-cell plug trays under 11.5, 12.5, 13.5 hours and natural day length. These seedlings were transplanted to the pot (16 cm In diameter) and grown under 16 hours day length. Number of leaves and neck diameter showed better growth in the longer than shorter day length treatments, but plant height old sheath length were retarded in the longer day length treatments. Growth such as no. of leaves, neck diameter, plant height and sheath length increased with the passage of day, but plant height and neck diameter decreased by treatment over 20 days with 13.5 hours day length. Bulbing and bulb size of onion after transplanting were enhanced in the seedlings cultured under longer day lengths. From the above results, treatment of long day length during seedling culture in plug tray can control the overgrowth and produce high quality plug seedlings.

Effects or air current speeds on the growth or eggplant plug seedlings in a wind tunnel under artificial lighting (인공광하의 풍동내에서 기류속도가 가지 플러그묘의 생장에 미치는 영향)

  • 김용현
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.9-14
    • /
    • 1998
  • Air current speeds were controlled of 0.3, 0.5, 0.7 and 0.9 m.s$^{-1}$ to investigate the effects of air current speeds on the growth of eggplant plug seedlings (Solanum melongena L.) in a wind tunnel under artificial lighting. Growth of plug seedlings was influenced by the magnitude of air current speed and the traveling distance of regulated air flow. Stem length. ratio of length to diameter in stem, plant height .and number of leaves of plug seedlings decreased with the increasing air current speed and were significantly different at 5% level. Net photosynthetic rates of plug stand increased with the increasing air current speed and took a maximum value at the air current speed of 0.7~09 m.s$^{-1}$ . Stem diameter decreased and leaf area increased with the traveling distance of regulated air flow. Fresh weight and T/R ratio of dried weight were not influenced by the air current speed. Optimum control for microclimates inside the plug stand is needed to produce the uniform growth and high quality of plug seedlings in a semi-closed plant Production system under artificial lighting.

  • PDF

Bearing Capacity of Model Open -Ended Steel Pipe Pile Driven into Sand Deposit (모래지반에 타입된 모형 개단강관 말뚝의 지지력 분석)

  • Baek, Gyu-Ho;Lee, Jong-Seop;Lee, Seung-Rae
    • Geotechnical Engineering
    • /
    • v.9 no.1
    • /
    • pp.31-44
    • /
    • 1993
  • Model tests in calibration chamber with open -ended steel pipe pile have been performed in sand deposit to clarify effect of soil plug on bearing capacity, load transfer mechanisms in soil plug, and behavior of soil plug under dynamic and static conditions. Model piles were devised so that bearing capacity of open -ended pile could be measured separately into outside skin friction, inside skin friction due to soil plug -pile interaction and end bearing force on the section of steel pipe pile. It may be concluded, form the test results, that the plugging level of open -ended pile is more correctily defined by specific recovery ratio, y, rather than by plug length ratio, PLR, and the major part of inside skin friction is generated within the range of three times as long as the inner diameter of the pile from the pile tip. The ratio of inside skin friction to total bearing capacity is much larger than that of outside skin friction to total bearing capacity. Therefore, the bearing capacity of pile could not be well predicted, unless the inside skin friction is properly taken into account.

  • PDF

Effects of $\textrm{CO}_2$ concentration and air current speed on the growth and development of plug seedlings under artificial lighting (인공광하에서 $\textrm{CO}_2$ 농도와 기류속도 제어가 플러그묘의 생육에 미치는 효과)

  • 송대빈;김용현
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.275-280
    • /
    • 1999
  • This study was conducted to investigate the effects of $CO_2$ concentration(310 or 950$\mu$ mol.mol$^{-1}$ ) and air current speed(0.3, 0.5, 0.7 or 0.9m.s$^{-1}$ ) on the growth and development of eggp1ant Plug seedlings (Solanum melongena L.) under artificial 1ighting. For the treatment of $CO_2$ enrichment, stem length and diameter, the ratio of stem length to stem diameter, plant height, leaf area, net photosynthetic rate, top dried weight were significantly different at 1% level. Stem length of plug seedlings decreased at the condition under enriched $CO_2$ and high air current speed above plug stand. Stem diameter of plug seedlings increased and plant height decreased with the increasing $CO_2$ concentration. Plug seedlings had maximum net photosynthetic rate at the air current speed of 0.7m.s$^{-1}$ . Net photosynthetic rate at $CO_2$ concentration of 950$\mu$mol.mol$^{-1}$ increased by 46% than those at 310$\mu$mol.mol$^{-1}$ . Thus $CO_2$ enrichment would be effective for the production of plug seedlings with high quality.

  • PDF

A study on Applicable to Advanced treatment of using Side Stream Plug-Flow Reactor (효과적 공간활용을 위한 Side Stream Plug-Flow Reactor를 이용한 하수 고도처리 공정 적용에 관한 연구)

  • Kim, samju;Hyun, InHwan;Dockko, Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.367-372
    • /
    • 2008
  • This study configured the conventional $A^2O$ (Anaerobic-Anoxic-Aerobic bioreactor) system which the fixed media immersed into the anoxic reactor(Named PFR system : Plug Flow Reactor) for evaluating the removal efficiency of nitrogen in the wastewater. The experimental equipment was a cylinder which was consist of 4 pleated PE Pipes(Length 330M, Diameter 100mm) including 2 rope shape media. As a result, the average effluent T-N removal efficiency of the conventional $A^2O$ system was 17.9, 40.3, 50.6, 44.6% in each mode, but the average effluent T-N removal efficiency of the PFR system could achieve 38.8, 57.1, 71.8, 65.4% in each mode. It indicated that the PFR system caused to the increasing of C/N ratio that effected to the increasing of the denitrification efficiency. Not only the effective T-N removal efficiency but also the controllable install space will give advantages for retrofitting of the wastewater treatment plant with the conventional treatment system to the PFR system.