Research for Signal Interfaces between DOORS of DRIVERLESS TRAIN and PSD Control (무인운전 차량의 도어 및 PSD 제어 신호에 대한 연구)

  • Lee, Hee-Chang;Kim, Dong-Il;Chun, Sang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.857-865
    • /
    • 2010
  • Recently the demand of the driverless rolling stock is increasing with advancement of the stable communication technique and control technique. The automatic train operating system has advantages which takes low operating cost and is able to dispose elastically in demand. Beside it provides high safety and effectiveness because it will be able to control power, signal and communication system from Operation Control Center and the safety and effectiveness are high. The establishment of PSD, Platform Screen Door, is advanced in the goal which is passenger safety, fire protection, noise and dust reduction etc. When but, two advanced systems also have risks of operation delay and accident when two systems are not controlled smoothly. Thus, I'll introduce control method between onboard controller, door control unit in rolling stock and PSD controller to help system design.

  • PDF

PSD Door Response Time Improving Method in Train Manual Operation Mode (수동운전방식에서의 PSD 출입문 신호반응 시간 개선 방안 연구)

  • Lee, Moo-Ho;Kim, Chan-Cum;Lee, Suk-Jong;Lee, Soo-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.559-571
    • /
    • 2008
  • Platform Screen Door(PSD) has been installed and operated at seoul subway line $1\sim4$ in the manual train operation mode(ATS/ATC) by SeoulMetro since 2005. SeoulMetro uses the wireless (RF) communication system and the train door detection system for the link between the train and PSD doors opening/closing motion in the manual train operation mode. For the convenience and safety of passengers, the train doors and the PSD doors opening/closing shall be synchronized as much as possible. In ATO(Automatic Train Operation) mode which provides the interface between train control system and PSD system, ATO signaling system makes the train doors and PSD doors open/close command signals systematically, so PSD doors can be opened/closed almost simultaneously with the train doors. But, in the manual train control(ATS/ATC) mode, PSD system needs to detect the train doors open/close operation and make PSD open/close command signals to actuate PSD doors. These PSD open/close commanding process cause time delay of PSD doors opening/closing motion in response to the train doors opening/closing motion. Sometimes the response delay time can be over 1 second, which is not proper to operate PSD, and need to be reduced This paper presents the reduction method of the PSD response delay time to improve the convenience and safety of passengers.

  • PDF

A study on the improvement of the air exhaust system at the PSD installed subway station (도시철도 지하역사 PSD 설치에 따른 배기시스템 개선 연구)

  • Kwon, Soon-Bark;Song, Ji-Han;Ryu, Ju-Hwan;Jo, Seung-Won;Oh, Tae-Suk;Bae, Sung-Joon;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.353-362
    • /
    • 2015
  • Platform screen door (PSD) installed at underground subway station has reduced the safety accident, but it may cause poor air ventilation condition due to the isolated exhaust duct in the subway tunnel area. In this study, the additional ventilation system was suggested, which can be installed at a void space (i.e., storage room under stairs) of platform in order to improve efficiency of air ventilation rate. Exhausted air from platform was directed to underneath of platform and joined with existing ventilation duct of train exhaust system (TES). One subway station in Seoul city was selected to predict the effectiveness of the suggested lower exhaust system by using the computational fluid dynamics (CFD) analysis. The predicted mean age of air was decreased by 16.5% which proves the improvement of air ventilation efficiency when the suggested lower exhaust system was applied.

Smoke Control in a Subway Station Platform with Screen Doors - Based on Busan Subway Line 3 - (스크린도어 설치에 따른 지하승강장 제연의 문제점과 대책 - 부산 지하철 3호선을 중심으로 -)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.50-54
    • /
    • 2006
  • A fire in a subway station platform, completely isolated by screen doors, was numerically simulated to investigate problems in smoke control and find their countermeasures. A part of the platform, $40m{\times}5m$ floor and 3 m high, and a fire of 1 MW were considered, and the smoke extraction system was assumed to start operation at the onset of the fire. For three different values of the exhaust air flow rate, 0.1, 2, and $4m^3/min-m^2$, the distributions of temperature, concentrations of soot and carbon monoxide, and those of visibility were compared. The time-variations of the number of randomly distributed particles in the space were also investigated for the air flow rates to see the efficiency in smoke control. It was shown that smoke control takes time by lack of air supply. It was also confirmed that air supply from the railway to the platform at emergency is needed so that smoke is able to be controlled efficiently, and that opening the doors at the both ends of the platform is desirable until the fire is completely extinguished.

Development of Safety Equipment using Laser Radar Sensor for Railway Platform

  • Hwang, Jong-Gyu;Kim, You-Ho;Jo, Hyun-Jeong;Choi, Kwon-Hee;Ko, Tae-Kuk
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.35-40
    • /
    • 2010
  • Many casualties are being occurred due to many misses the railway platform, and the accident occurrence is being increased. Recently in Korea, efforts to prevent casualties fundamentally are being made by installing and operating the PSD(Passenger Screen Door) as to prevent these casualties of passengers. However, in case of the PSD system, although it can solve the problem of public casualties at platform fundamentally, it is impossible to install it at whole railway platforms. This paper proposes the safety equipment using LaserRadar sensor for the prevention against casualties of passengers at platform. The safety equipment using novel sensor is the safety equipment making an approaching train stopped if the falling object is a person by detecting the obstacle at platform, and it has the merit possible to apply it to platform since it may detect accurately under ambient environmental elements such as the snow, rain and yellow dust, etc. also. We manufactured a prototype of the safety equipment to reduce public casualties at platform by using LaserRadar sensor and carried out its performance test, and the result is presented in this paper.

A Study on Improvement of PSD Interface Using 2.4GHz Wireless Communication, (2.4GHz 무선 통신을 이용한 PSD 인터페이스 개선에 관한 연구)

  • Kim, Jae-Pil;Hyun, Yong-Sub;Chang, Kyong-Song
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1408-1415
    • /
    • 2007
  • To operate Platform Screen Door (PSD) automatically, the operational data of PSD and the train must be interfaced properly. PSD and train are operated together by the signaling system in Automatic Train Operation (ATO) signaling system zone where interfaces are provided between PSD and train. However, the additional PSD interface system with train is required in train operating zone without the interface between PSD and train. For the PSD interface, the wireless communication system or the train status (train correct stop status / train door status) detection system has been used. Seoul Metro line No.2. has the PSD wireless communication system using 447MHz band RF. For the safety of PSD operation, it is required to prevent RF interference in the subway environment where many frequencies exist. In this paper, the PSD wireless communication system is developed using 2.4GHz band RF to prevent the interference of the wireless communication and increase the traffic of the PSD interface. Furthermore, the improved system can store, manage and display the PSD and train operational data using Human Machine Interface (HMI) in the train's driver cab.

  • PDF

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

Study on Precise Positioning using Hybrid Track Circuit system in Metro (하이브리드 궤도회로를 이용한 지하철 정위치정차에 대한 연구)

  • Jung, Ho-Hung;Ko, Yang-Og;Li, Chang-Long;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.471-477
    • /
    • 2013
  • We have studied on the possibility of precise positioning using hybrid Track Circuit system. Hybrid Track Circuit uses RFID which replaces UHF. Hybrid Track Circuit is a part of next generation railroad signal system which is available to communicate with a railway on board system based on a realtime operating system. If applicate on a current hand operating subway, phenomenon caused by driver's mistake such as passing a stop without stopping or mismatch error between PSD and train door should be prevented.

Detection Method Analysis for Train Correct Position Stop in Manual Operation for PSD System (수동운전 방식에서의 PSD시스템을 위한 정위치정차 판독방법 분석)

  • Lee, Moo-Ho;Yang, Gi-Hee;Park, Jung-Soun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1678-1684
    • /
    • 2007
  • Platform Screen Door(PSD) has been installed in train manual operation section(ATS/ATC) by SeoulMetro since 2005. PSDs are now operating at 17 stations in SeoulMetro lines. As a result, it increases the safety of passenger, makes a comfortable platform and saves the energy of air conditioning. For PSD operation, train shall stop within 600mm of the train stop reference point. In train manual operation section, the detection system of train position is required to notify the train driver of train position and to ensure the condition that train stops the correct position for PSD operation. To detect the train stop position, the optical sensor shall be installed at platform. However, in case of SeoulMetro lines, the detection criterions of the train correct position stop are different because of using various types of trains which have different size and shape of front cars. In this paper, to solve this problem, the precise detection algorithm of the train stop at the correct position is used, and Laser distance measure sensor is introduced to notify the distance form the reference point of the train correct stop to train driver. This system has been applying to Seoul Metro line total.

  • PDF

A Study on the Unification of the Grounding System of Urban Railroad (도시철도 지하구간 접지설비 표준화 기준 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho;Sim, Jae-Chang
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.470-480
    • /
    • 2008
  • After 1th line was built in 1974, the history of subway in Korea has been expended to 9th line which is under construction. It is time to prepare nation wide subway grounding system urgently according to the domestic electric standard that aligns to world wide standard by WTO/TBT treat (1995). Newly added grounding system to the fundamentally different system caused many problems. PSD(platform screen door) and other newly added equipment are also need grounding system. By the electrical code(established by Korea Electric Association), low voltage equipment(including grounding system) under 1,000V AC are in the process of change into IEC 60374. IEC 60364 standard will be added to the electrical code(established by Korea Electric Association) in 2007 and amended and after 3-5 years later, it will become a complete IEC 60364. So the purpose of this study is to compare the domestic rail road grounding system and suggest the standardized grounding system for the newly built subway.

  • PDF