A Study for the Screen Door System Driving Stiffness of Motor Control Method (모터 제어 방식의 스크린 도어 시스템 구동강성 검증)

  • Lee, Jung-Hyun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2385-2390
    • /
    • 2015
  • In the beginning run, urban railway had been required as transportation. But now days urban railway have stayed in the platform for long time, the platform is faced the problem that is improvement of environment as one of the living space. Thus, sliding automatic door on the basis of screen door have used in huge distribution market, hospital, restaurant and public office because it is comfortable that customer's convenience and entrance are controled. So screen door not only requires customer's convenience and safe, clean area and energy conservation but demands optimal design technology development of screen door system that is confirmed by element parts of design and confidence. In this paper, For secure confidence of screen door, after as modeling roller and frame's system, confirming the result for qualification of driving stiffness. And then it suggests that it is possible to increase performance and declines fraction defective of element's part.

Allocation of Safety Integrity Level for Railway Platform Screen Door System considering Semi-Quantitative Risk Reduction Factor (반 정량적 리스크 저감 요소를 고려한 철도 승강장 스크린 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.156-163
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, the theoretical and practical study for safety integrity level is barely under way in the domestic railway industry. This research studied not only the global process of SIL allocation to guarantee safety in accordance with international standards for safety related equipment and system, but the quantitative methodology based on international standard and the semi-quantitative methodology as alternative way for SIL allocation. Specifically, the systematic SIL allocation for platform screen door system of railway is studied applying the semi-quantitative methodology in order to save much time and effort compared to quantitative method.

Allocation of Safety Integrity Level for Railway Platform Screen Door System based on Consequence Severity and Risk Graph (결과 심각도 및 리스크 그래프에 기반한 철도 승강장 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.164-173
    • /
    • 2015
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, application standard differs from every industry in domestic or international for application on mythology for allocation and demonstration of SIL. Application or assessment is not easy since absence on clear criteria or common definition. This research studied not only fundamental concept of SIL required to guarantee safety in accordance with international standards for safety related equipment and system, but different types of methodologies for SIL allocation. Specifically, SIL allocation for Platform Screen Door system of railway is studied applying methodology of severity of accidents and risk graph among different methodologies for SIL allocation.

Development of the Manual Opening and Closing Algorithm for Vertical Rope Type Platform Safe Door and Its Evaluation (상하개폐형 RPSD의 수동개폐 알고리즘 개발 및 평가)

  • Choi, Gapyeol;Kim, Hyun
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.3
    • /
    • pp.248-255
    • /
    • 2014
  • Though the Platform Screen Door System (PSD) has received a positive evaluation and is installed in all the Urban Railroad platforms, PSD is not installed in the Intercity Railroad platforms. The limitation of PSD in the Intercity Railroad platforms is due to the fact that first, various types of trains such as KTX, Saemaeul, Mugunghwa, and Nuriro stop at the platforms and their locations of the doors are different and secondly, they are not operated under ATO (automatic train operation). RPSD system currently under research and development, on the other hand, is based on the improved door that slides up and down and can be installed in any Intercity Railroad platform regardless of the length of the train, the location of doors, and the number of doors. This study considers the mechanism of RPSD, develops a manual open/close algorithm, and evaluates the function of RPSD. The results show that the manual open/close algorithm achieves a significant improvement in efficiency when provided with power supply.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

A Study on Signal Interlocking for Screen Door System (스크린도어 시스템 제어를 위한 신호 인터로킹 연구)

  • Kang, Dae-Yun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.811-820
    • /
    • 2006
  • The Platform Screen Door system(PSD) is scheduled to be installed on the platform of some subway stations in Seoul, Pusan, Kwang-Ju, Daejun and Daegu and all stations of Seoul Subway No 9. will equipped with PSD. On the other hand Seoul Metropolitan Rapid Speed(SMRT) that has operated the train automatically had finished the basic desic design and the execution drawing of PSD and installed successfully the PSD on the platforms in the Kimpo Airport station in Subway Line No 5. at dec. 2005. The exhibition operations of PSD has made the major contribution to build up the safe and optimum subway for the increasing customers. Nowadays PSD has operated on ATO sections and ATS sections. But in the case of closing the door manually in ATO sections, it would be delayed about 5 seconds in closing the door of PSD. Although the interface of PSD, train and the signal system is established automatically, we have to supplement technically on the interface between train, PSD and the ground signal interface equipments. Therefore I will center on the optimizing methods about the interfacing system between the train and the PSD, train and the signal system to overcome the above problems in this study.

  • PDF

Development of Hi-efficiency Direct Drive PMAC Controller for Screen Door (스크린도아용 고효율 직접구동 PMAC Driver 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.35-41
    • /
    • 2012
  • To control screen door installed in the subway platform, geared BLDC motors have been being used. However, because of the geared mechanisms, the control profile of the screen door in slow speed is very poor. Moreover, geared mechanism tends to leads system malfunctions and low efficiency. To overcome those problems, in this paper, the techniques of developing hi-efficiency direct drive gearless PMAC motor controller and application example to control the screen door of subway platforms are proposed. The developed system has advantages that; the energy efficiency has been increased by adopting gearless PMAC motor; the system break-down factor has been decreased due to the actuator mechanism has been simplified. In this paper, the screen door control system structure, PMAC motor drive circuit design, implementations of vector control algorithm, and test results are shown.

A NUMERICAL ANALYSIS OF THE TRAIN WIND IN THE SUBWAY TUNNEL (지하철 터널 내 열차풍의 수치해석적 연구)

  • Lee, J.H.;Juraeva, M.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.496-500
    • /
    • 2010
  • Understanding train-wind is the best method to know how to optimize subway ventilation system. The capacity and efficiency of the subway ventilation system are known by pressure and velocity while train runs. Analysis of the internal flow in subway tunnel and around subway station are studied using numerical methods. Characteristics of internal flow and influence of subway ventilation system for the subway station with platform screen door and tunnel are analyzed by unsteady state analysis. Velocity and pressure of train wind transformation are compared at around subway ventilation system and the internal flow is investigated at the subway tunnel.

  • PDF

A Study on the Sensibility Evaluation for the Human-centered Design of Rope Platform Screen Door(RPSD) (로프스크린도어의 인간중심 설계를 위한 감성평가에 관한 연구)

  • Jung, Byung Doo;Kim, Hyun;Shin, Kangwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.703-709
    • /
    • 2013
  • Recently, the study on the commercialization technology of Rope Platform Screen Door (RPSD) is on the process. The study is specifically on RPSD, which the rope screen ascends to allow passage with securing safety of passenger and the condition of aboveground station. For this human-centered design of RPSD, it is important to present system technology. However, it is also necessary to scientifically measure and research the emotions, senses or minds of users in the future. Therefore, this study analyzed the human factors to be considered with designing the system on RPSD, which is installed in Nokdong Station on Gwangju Subway as a trial. Moreover, the emotional evaluation was done by analyzing the factors as how they are effected in general; it processed by checking whether it is safe, height of rope is stable, it has openness (pressure) or strong by examining the moments that a set of ropes blocks rail from platform, and when train is arrived.

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.