• 제목/요약/키워드: Plate fixation

검색결과 346건 처리시간 0.025초

대퇴부 원위부 골절에 관한 금속판 보강술의 응력 해석 (Stress Analysis of Plate Augumentation for Distal Femur Fracture)

  • 김지숙;범현규;양영수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.816-819
    • /
    • 1997
  • The operation of femoral non-union after IM(Intramedullary) nailing in distally femoral fractures is considered. Augmentive plate fixation is the management of femoral non-union after IM nailing. The purpose of this study is to compare the bending, torsional stiffness and stress distribution of the two operations by the FEM(Finite Element Method). Augmentive plate fixation is better than IM nail fixation. These results conclude that plate augmentation is a useful method for the unstable femoral non-union after interlocking IM nailing.

  • PDF

Comparison of postoperative changes in the distal and proximal segments between conventional and sliding mini-plate fixation following mandibular setback

  • Kim, Seong-Sik;Kwak, Kyoung-Ho;Ko, Ching-Chang;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Il
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.372-378
    • /
    • 2016
  • Objective: The purpose of the present study was to evaluate the postoperative three-dimensional (3D) changes in the proximal segments after mandibular setback sagittal split ramus osteotomy and to compare the changes between the conventional mini-plate fixation and semi-rigid sliding plate fixation. Methods: Cone-beam computed tomography (CBCT) images were used to evaluate the postoperative 3D changes in the proximal segments during the healing process. CBCT images were superimposed using the symphysis and the lower anterior mandible as references. Results: There were no statistically significant differences between the conventional mini-plate and semi-rigid sliding plate groups (p > 0.05). With respect to the distribution of changes greater than 2 mm in the landmarks, the right condylion, right coronoid process, and left condylion showed ratios of 55.6%, 50.0%, and 44.4%, respectively, in the semi-rigid sliding plate group; however, none of the landmarks showed ratios greater than 30% in the conventional mini-plate group. Conclusions: There were no statistically significant differences in postoperative changes in the segments between the conventional mini-plate and semi-rigid sliding plate groups. Nevertheless, while selecting the type of fixation technique, clinicians should consider that landmarks with greater than 2 mm changes were higher in the semi-rigid sliding plate group than in the conventional mini-plate group.

하악골 시상골 골절단술시 MINIPLATE에 의한 RIGID FIXATION (RIGID FIXATION BY MINIPLATE IN THE MANDIBULAR SAGITTAL SPLITRAMUS OSTEOTOMY.)

  • 조병욱;이용찬;양용석;유하식
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권2호
    • /
    • pp.48-54
    • /
    • 1990
  • This is a report of 4 cases of the surgical correction of mandibular prognathism with chief complaint of mastication difficulty, facial asymmetry and protrusive chin. We performed sagittal spit ramus osteotomy for the prognathism, we used the repositioning plate for conserving the condylar segment into its original position and fixed the osteotomized bone segments rigidly with adjustable monocortical plate. Intermaxillary fixation was performed during 2 weeks. As a results, we found the following advantage. 1. Rigid fixation effect like the fixation by the tandem screw. 2. Decreased postoprative swelling. 3. It is needless to do the stab incision for the transbuccal set instrument. 4. It is more convenient to perform the rigid fixation in the monocortical plate method than screw technique.

  • PDF

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.

Orthogonal versus Parallel Plating for Distal Humeral Fractures

  • Moon, Jun-Gyu;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.105-112
    • /
    • 2015
  • In orthopedic trauma surgery, treatment of intraarticular distal humerus fractures is a challenge. With development of implants and biomechanical studies, surgical strategies with recommendations including preoperative computed tomography images, proper approaches and open reduction and internal fixation with dual plates have emerged. In addition, as an effort to provide stable fixation to permit early elbow motion, different methods of internal fixation, particularly plate configuration, have evolved. Using dual plates, either oriented parallel to each other or orthogonal, stable fixation has been achieved and satisfactory clinical outcomes have been reported. With rationales and advantages/disadvantages of each plate configuration, both techniques are selected according to surgeons' preference, and, in specific cases, one could be preferred over another. The key to successful fixation by either technique is obtaining anatomical reduction with restoration of two stable columns of the distal humerus.

흡수성 망상판과 나사를 이용한 안면골절의 견고정법 (Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture)

  • 신동혁;김덕중;김수영;황은아;최현곤;김순흠;엄기일
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

대퇴골(Femur)고정용 골 금속판 제작 및 강도 평가 (Practicability Strength Assessment of a Bone Metallic Plate at the Femur Fixation)

  • 김정래;안창식;서병도
    • 대한인간공학회지
    • /
    • 제27권2호
    • /
    • pp.83-89
    • /
    • 2008
  • Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.

불안정 원위 쇄골 골절의 수술적 치료: 경견봉 강선 고정술과 갈고리형 금속판 고정술의 비교 (Surgical Treatment of Unstable Distal Clavicle Fractures: Comparison of Transacromial Pin Fixation and Hook Plate Fixation)

  • 김영성;이호민;장한길
    • Clinics in Shoulder and Elbow
    • /
    • 제16권2호
    • /
    • pp.123-129
    • /
    • 2013
  • 서론: 불안정성 쇄골 원위부 골절에 대하여 변형된 경견봉 강선 고정술과 갈고리형 금속판 고정술을 시행 후 결과를 비교하였다. 대상 및 방법: Neer 분류 제 2형 골절에 대하여 경견봉 강선 고정술 혹은 갈고리형 금속판 고정술을 시행하고 1년 이상 추시가 가능하였던 24명을 대상으로 하였다. 경견봉 강선 고정술(group I)을 시행한 경우가 12명, 갈고리형 금속판 고정술(group II)을 시행한 경우가 12명이었다. 정복 및 골유합의 평가는 수술 직후 및 최종 방사선 사진을 이용하였고, 기능적 평가는 최종 추시 시의 UCLA score 및 Constant-Murley score를 측정하여 비교하였다. 결과: 수술 뒤 group I은 평균 10주, group II는 평균 11.7주에 모든 예에서 골유합을 관찰할 수 있었다. 최종 추시 시의 평균 UCLA score는 group I은 33점, group II는 32.8점이었으며, 평균 Constant score는 group I은 88.5점, group II는 88.8점으로 두 기능적 평가 결과 통계적으로 유의한 차이는 없었다. 결론: Neer 분류 제 2형 원위 쇄골 골절에서 경견봉 강선 고정술과 갈고리형 금속판 고정술은 만족할 만한 결과를 얻을 수 있어 모두 유용한 방법으로 생각된다.

Surgical Treatment of Sternoclavicular Joint Dislocation Using a T-plate

  • Hwang, Wan Jin;Lee, Yeiwon;Yoon, Yoo Sang;Kim, Young Jin;Ryu, Han Young
    • Journal of Chest Surgery
    • /
    • 제49권3호
    • /
    • pp.221-223
    • /
    • 2016
  • A 22-year-old man was hospitalized with a sternoclavicular joint (SCJ) dislocation caused by a traffic accident. Surgical reduction and fixation of the SCJ were performed using a T-plate. SCJ dislocation is rare, accounting for less than 1% of all dislocations, and is usually treated conservatively, although severe cases may require surgery. Surgery typically involves joint reduction and fixation using an autologous tendon graft, but this has disadvantages such as the requirement for additional surgery to obtain autologous tissue and an extended operative time. To overcome these issues, here, we performed a simple SCJ reduction and fixation using a T-plate and achieved good results.