1 |
An SH, Kim HC, Kim KY, Lee JH, Yoon SH. Complications of Hook-plate fixation for distal clavicle fractures. J Korean Fracture Soc. 2012;25:38-45.
DOI
|
2 |
Nordqvist A, Petersson C, Redlund-Johnell I. The natural course of lateral clavicle fracture. 15 (11-21) year follow-up of 110 cases. Acta Orthop Scand. 1993;64:87-91.
|
3 |
Neer CS II. Fractures of the distal third of the clavicle. Clin Orthop Relat Res. 1968;58:42-50.
|
4 |
Kona J, Bosse MJ, Staeheli JW. Type II distal clavicle fractures: A retrospective review of surgical trauma. J Orthop Trauma. 1990;4:115-20.
DOI
|
5 |
Kao FC, Chao EK, Chen CH, Yu SW, Chen CY, Yen CY. Treatment of distal clavicle fractures using Kirschner wires and tension bend wires. J Trauma. 2001;51:522-5.
DOI
ScienceOn
|
6 |
Ballmer FT, Gerber C. Coracoclavicular screw fixation for unstable fractures of the distal clavicle; a report of five cases. J Bone Joint Surg Br. 1991;73: 291-4.
|
7 |
Mizue F, Shirai Y, Ito H. Surgical treatment of comminuted fractures of the distal clavicle using Wolter clavicular plates. J Nippon Med Sch. 2007;6: 32-4.
|
8 |
Muramatsu K, Shigetomi M, Matsunaga T, Murata Y, Taguchi T. Use of the AO hook-plate for treatment of unstable fractures of the distal clavicle. Arch Orthop Trauma Surg. 2007;127:191-4.
DOI
ScienceOn
|
9 |
Anderson JR, Willis MP, Nelson R, Mighell MA. Precontoured superior locked plating of distal clavicle fractures: A new strategy. Clin Orthop Relat Res. 2011;469:3344-50.
DOI
|
10 |
Anderson K. Evaluation and treatment of distal clavicle fractures. Clin Sports Med. 2003;22:319-26.
DOI
ScienceOn
|
11 |
Fann CY, Chiu FY, Chuang TY, Chen CM, Chen TH. Transacromial Knowles pin in the treatment of Neer type 2 distal clavicle fractures: a prospective evaluation of 32 cases. J Trauma. 2004;56:1102-5.
DOI
|
12 |
Mall JW, Jocobi CA, Philipp AW, Peter FJ. Surgical treatment of unstable fractures of the distal clavicle with polydioxanone suture tension band wiring: an alternative osteosynthesis. J Orthop Sci. 2002;7: 535-7.
DOI
ScienceOn
|
13 |
Goldberg JA, Bruce WJ, Sonnabend DH, Walsh WR. Type 2 fractures of the distal clavicle: a new surgical technique. J Shoulder Elbow Surg. 1997;6: 380-2.
DOI
ScienceOn
|
14 |
Kim KC, Shin HD, Cha SM, Jeon YS. Hook plate fixation for unstable distal clavicle fractures:a prospective study. Clin Shoulder Elbow. 2011;14:6-12.
DOI
|
15 |
Edwards DJ, Kavanagh TG, Flannery MC. Fractures of the distal clavicle: a case for fixation. Injury. 1992;23:44-6.
DOI
ScienceOn
|
16 |
Yamaguchi H, Arakawa H, Kobayashi M. Result of the Bosworth method for unstable fractures of the distal clavicle. Int Orthop. 1998;22:366-8.
DOI
ScienceOn
|
17 |
Neer CS II. Fractures of the distal clavicle with detachment of the coracoclavicular ligaments in adults. J Trauma. 1963;3:99-110.
DOI
ScienceOn
|
18 |
Eskola A, Vainiopaa S, Patiala H, Rokkanen P. Outcome of operative treatment in fresh lateral clavicular fracture. Ann Chir Gynaecol. 1987;76:167-9.
|
19 |
Nadarajah R, Mahaluxmivala J, Amin A, Goodier DW. Clavicular hook-plate: complications of retaining the implant. Injury. 2005;36:681-3.
DOI
ScienceOn
|
20 |
Meda PV, Machani B, Sinopidis C, Braithwaite I, Brownson P, Frostick SP. Clavicular hook plate for lateral end fractures: a prospective study. Injury. 2006;37:277-83.
DOI
ScienceOn
|
21 |
Renger RJ, Roukema GR, Reurings JC, Raamas PM Font J, Verleisdonk EJ. The clavicle hook plate for Neer type II lateral clavicle fractures. J Orthop Trauma. 2009;23:570-4.
DOI
ScienceOn
|
22 |
Klein SM, Badman BL, Keating CJ, Devinney DS, Frankle MA, Mighell MA. Result of surgical treatment for unstable distal clavicle fractures. J Shoulder Elbow Surg. 2010;19:1049-55.
DOI
ScienceOn
|
23 |
Flinkkila T, Ristiniemi J, Hyvonen P, Hamalainen M. Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand. 2002;73:50-3.
DOI
ScienceOn
|
24 |
Naidoo P. Migration of a Kirschner wire from the clavicle into the abdominal aorta. Arch Emerg Med. 1991;8:292-5.
DOI
|
25 |
Tsai CH, Hsu HC, Huan CY, Chen HT, Fong YC. Late migration of threaded wire (Schanz screw) from right distal clavicle to the cervical spine. J Chin Med Assoc. 2009;72:48-51.
DOI
ScienceOn
|