Browse > Article
http://dx.doi.org/10.5397/cise.2015.18.2.105

Orthogonal versus Parallel Plating for Distal Humeral Fractures  

Moon, Jun-Gyu (Department of Orthopedic Surgery, Korea University Guro Hospital)
Lee, Ji-Ho (Department of Orthopedic Surgery, Korea University Guro Hospital)
Publication Information
Clinics in Shoulder and Elbow / v.18, no.2, 2015 , pp. 105-112 More about this Journal
Abstract
In orthopedic trauma surgery, treatment of intraarticular distal humerus fractures is a challenge. With development of implants and biomechanical studies, surgical strategies with recommendations including preoperative computed tomography images, proper approaches and open reduction and internal fixation with dual plates have emerged. In addition, as an effort to provide stable fixation to permit early elbow motion, different methods of internal fixation, particularly plate configuration, have evolved. Using dual plates, either oriented parallel to each other or orthogonal, stable fixation has been achieved and satisfactory clinical outcomes have been reported. With rationales and advantages/disadvantages of each plate configuration, both techniques are selected according to surgeons' preference, and, in specific cases, one could be preferred over another. The key to successful fixation by either technique is obtaining anatomical reduction with restoration of two stable columns of the distal humerus.
Keywords
Humerus; Humeral fractures; Fracture fixation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Abzug JM, Dantuluri PK. Use of orthogonal or parallel plating techniques to treat distal humerus fractures. Hand Clin. 2010;26(3):411-21, vii.   DOI   ScienceOn
2 Goel DP, Pike JM, Athwal GS. Open reduction and internal fixation of distal humerus fractures. Oper Tech Orthop. 2010;20(1):24-33.   DOI   ScienceOn
3 Green A. Surgical treatment of bicolumn distal humeral fractures: relevant anatomy and classification. Instr Course Lect. 2009;58:505-7.
4 Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma. 2009;66(3):795-9.   DOI   ScienceOn
5 Schemitsch EH, Tencer AF, Henley MB. Biomechanical evaluation of methods of internal fixation of the distal humerus. J Orthop Trauma. 1994;8(6):468-75.   DOI   ScienceOn
6 Schuster I, Korner J, Arzdorf M, Schwieger K, Diederichs G, Linke B. Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J Orthop Trauma. 2008;22(2):113-20.   DOI   ScienceOn
7 Wong AS, Baratz ME. Elbow fractures: distal humerus. J Hand Surg Am. 2009;34(1):176-90.   DOI   ScienceOn
8 Ramsey ML. Surgical exposures for bicolumn distal humeral fractures. Instr Course Lect. 2009;58:509-14.
9 Seigerman DA, Choung EW, Yoon RS, et al. Identification of the radial nerve during the posterior approach to the humerus: a cadaveric study. J Orthop Trauma. 2012;26(4):226-8.   DOI   ScienceOn
10 Yildirim AO, Oken OF, Unal VS, Esmer AF, Gülçek M, Ucaner A. Avoiding iatrogenic radial nerve injury during humeral fracture surgery: a modified approach to the distal humerus. Acta Orthop Traumatol Turc. 2012;46(1):8-12.   DOI
11 McCann PA, Smith GC, Clark D, Amirfeyz R. The tricipital aponeurosis: a reliable soft tissue landmark for humeral plating. Hand Surg. 2015;20(1):53-8.   DOI   ScienceOn
12 Jupiter JB, Neff U, Holzach P, Allgower M. Intercondylar fractures of the humerus. An operative approach. J Bone Joint Surg Am. 1985;67(2):226-39.   DOI
13 Korner J, Diederichs G, Arzdorf M, et al. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma. 2004;18(5):286-93.   DOI   ScienceOn
14 Helfet DL, Schmeling GJ. Bicondylar intraarticular fractures of the distal humerus in adults. Clin Orthop Relat Res. 1993;(292):26-36.
15 Sanchez-Sotelo J, Torchia ME, O'Driscoll SW. Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. J Bone Joint Surg Am. 2007;89(5):961-9.   DOI   ScienceOn
16 Henley MB, Bone LB, Parker B. Operative management of intra-articular fractures of the distal humerus. J Orthop Trauma. 1987;1(1):24-35.   DOI
17 Holdsworth BJ, Mossad MM. Fractures of the adult distal humerus. Elbow function after internal fixation. J Bone Joint Surg Br. 1990;72(3):362-5.
18 Letsch R, Schmit-Neuerburg KP, Sturmer KM, Walz M. Intraarticular fractures of the distal humerus. Surgical treatment and results. Clin Orthop Relat Res. 1989;(241):238-44.
19 O'Driscoll SW. Optimizing stability in distal humeral fracture fixation. J Shoulder Elbow Surg. 2005;14(1 Suppl S):186S-94.   DOI   ScienceOn
20 O'Driscoll SW. Parallel plate fixation of bicolumn distal humeral fractures. Instr Course Lect. 2009;58:521-8.
21 Schwartz A, Oka R, Odell T, Mahar A. Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures. Clin Biomech (Bristol, Avon). 2006;21(9):950-5.   DOI   ScienceOn
22 Got C, Shuck J, Biercevicz A, et al. Biomechanical comparison of parallel versus 90-90 plating of bicolumn distal humerus fractures with intra-articular comminution. J Hand Surg Am. 2012;37(12):2512-8.   DOI   ScienceOn
23 Self J, Viegas SF, Buford WL Jr, Patterson RM. A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg. 1995;4(1 Pt 1):10-6.   DOI   ScienceOn
24 Zalavras CG, Vercillo MT, Jun BJ, Otarodifard K, Itamura JM, Lee TQ. Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures. J Shoulder Elbow Surg. 2011;20(1):12-20.   DOI   ScienceOn
25 Stoffel K, Cunneen S, Morgan R, Nicholls R, Stachowiak G. Comparative stability of perpendicular versus parallel doublelocking plating systems in osteoporotic comminuted distal humerus fractures. J Orthop Res. 2008;26(6):778-84.   DOI   ScienceOn
26 Penzkofer R, Hungerer S, Wipf F, von Oldenburg G, Augat P. Anatomical plate configuration affects mechanical performance in distal humerus fractures. Clin Biomech (Bristol, Avon). 2010;25(10):972-8.   DOI   ScienceOn
27 Sabalic S, Kodvanj J, Pavic A. Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model. Injury. 2013;44 Suppl 3:S56-61.   DOI   ScienceOn
28 Caravaggi P, Laratta JL, Yoon RS, et al. Internal fixation of the distal humerus: a comprehensive biomechanical study evaluating current fixation techniques. J Orthop Trauma. 2014;28(4):222-6.   DOI   ScienceOn
29 Arnander MW, Reeves A, MacLeod IA, Pinto TM, Khaleel A. A biomechanical comparison of plate configuration in distal humerus fractures. J Orthop Trauma. 2008;22(5):332-6.   DOI   ScienceOn
30 Shin SJ, Sohn HS, Do NH. A clinical comparison of two different double plating methods for intraarticular distal humerus fractures. J Shoulder Elbow Surg. 2010;19(1):2-9.   DOI   ScienceOn
31 Tian D, Jing J, Qian J, Li J. Comparison of two different doubleplate fixation methods with olecranon osteotomy for intercondylar fractures of the distal humeri of young adults. Exp Ther Med. 2013;6(1):147-51.   DOI
32 Kimball JP, Glowczewskie F, Wright TW. Intraosseous blood supply to the distal humerus. J Hand Surg Am. 2007;32(5):642-6.   DOI   ScienceOn
33 Lee SK, Kim KJ, Park KH, Choy WS. A comparison between orthogonal and parallel plating methods for distal humerus fractures: a prospective randomized trial. Eur J Orthop Surg Traumatol. 2014;24(7):1123-31.   DOI   ScienceOn
34 Sanchez-Sotelo J, Torchia ME, O'Driscoll SW. Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. Surgical technique. J Bone Joint Surg Am. 2008;90 Suppl 2 Pt 1:31-46.   DOI   ScienceOn
35 Green A. Postoperative management after open reduction and internal fixation of distal humeral fractures. Instr Course Lect. 2009;58:535-9.