• 제목/요약/키워드: Plate electrode

검색결과 398건 처리시간 0.032초

평행 평판 정전형 구동기를 이용한 가변 광 감쇠기 (Variable Optical Attenuator using Parallel Plate Electrostatic Actuator)

  • 김태엽;허재성;문성욱;신현준;이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.448-452
    • /
    • 2004
  • The micromachined variable optical attenuator(VOA) was presented in the paper. The VOA has two single mode fiber(SMF) aligned with free space and symmetric parallel plate actuator with microshutter, which can control a amount of light by driving the actuator. In the paper, analysis on driving performances of the VOA was performed and can be reduced threshold voltage through the decreasing displacement actuating range. This paper presents a VOA that is fabricated using bosch deep silicon etching process with silicon on insulator(SOD wafer. The VOA consists of driving electrode, ground electrode, actuating microshutter, and mechanical stopper. In this VOA, actuating shutter is driven by electrostatic force and the threshold voltage is close to 28V, 46V come along with the spring width of 5${\mu}{\textrm}{m}$, 7${\mu}{\textrm}{m}$ respectively. Attenuation range is measured from 2.4㏈ to 16.7㏈.

Effect of Amino Silane Coupling Agent on the AC Electrical Breakdown Phenomena of Epoxy/Layered Silicate Nanocomposite in Needle-plate Electrodes

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.149-152
    • /
    • 2012
  • The effects of amino silane coupling agent on the AC electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were examined in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin by using our AC electric field apparatus. To measure the tree initiation and propagation and the breakdown rate, an alternating current (AC) of 10 kV (60 Hz) was applied to the specimen in needle-plate electrode arrangement with a $30^{\circ}C$ insulating oil bath. In the epoxy/amino silane system, the tree initiation time was 11.5 times higher and the breakdown time was 17.9 times higher than those of the neat epoxy resin. The tree initiation time in the epoxy/layered silicate (1 wt%) system with the amino silane was 2.0 times higher, and the breakdown time was 1.5 times higher than those of the epoxy/layered silicate (1 wt%) system.

분석적 모델을 이용한 Floated Field Plate구조가 있는 소자의 시뮬레이션 개선 (Improvement for Simulation of Device equipped with Heated Field Plate Using Analytic Model)

  • 변대석;김한수;최연익;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1283-1285
    • /
    • 1993
  • A new simulation method for a device including the Floated Field Plate(FFP) is proposed. The external resistance is connected with FFP in order to simulate FFP as a electrode. The numerical I-V characteristic obtained from MEDICI simulation shows fairly good results such as low leakage current and abrupt breakdown voltage curve. The convergence is improved conveniently compared with conventional method which utilize heavily-doped poly silicon as a electrode.

  • PDF

해수전해장치 전해조 개선에 의한 전극 부착물 저감 (Reduction of Deposits on the Electrode by the Cell Modification in Direct Sea Water Electrolysis System)

  • 박승수;김기형;안희수;박광규;이태원
    • 공업화학
    • /
    • 제16권4호
    • /
    • pp.563-569
    • /
    • 2005
  • 발전소에서 운영하고 있는 해수전해장치의 전극에 부착물이 다량으로 부착하여 성능이 저하되고 전극 손상사고가 발생하고 있어 전극 부착물을 억제할 수 있는 방안을 연구하였다. 현재 사용하고 있는 grating type의 양극을 plate type으로 변경하고 양극판 수를 9매에서 8매로 줄이는 한편, 전극 간격을 2.4 mm에서 3.0 mm로 늘리고, 극간 간격을 유지하기 위한 스페이서를 27개에서 10개로 줄인 전해조를 개발하였다. 발전소 현장에 개발 전해조를 설치하여 성능을 시험한 결과 기존의 제품에 비하여 전류효율은 15~20% 높았고, 전극 부착물은 36~60% 감소하였으며, 전력소비율은 20% 정도 낮은 것으로 나타났다.

열처리 방법에 따른 카본전극 페로브스카이트 태양전지의 특성 변화 (Properties of the carbon electrode perovskite solar cells with various annealing processes)

  • 송오성;김광배
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.26-32
    • /
    • 2021
  • 카본 전극 페로브스카이트 태양전지의 광활성층을 형성하는데 열판, 오븐, 쾌속열처리로 방법을 달리하며 이때 광전기적 특성과 미세구조 변화를 확인하였다. Glass/FTO/compact TiO2/meso TiO2/meso ZrO2/perovskite/carbon electrode 구조의 페로브스카이트 태양전지 소자를 열판 공정, 오븐 공정, RTA(rapid thermal annealing) 공정을 이용하여 준비하였다. 이때 광전기적 특성과 미세구조를 solar simulator와 광학현미경, 장발산주사전자현미경을 이용하여 각 소자의 특성을 분석하였다. 광전기적 특성 분석 결과, RTA 공정을 이용하여 제작한 소자에서 가장 우수한 광전기적 특성을 확인할 수 있었다. 미세구조 분석 결과 열판 공정과 오븐 공정으로 제작한 시편은 카본 전극 상부에 과잉 페로브스카이트 상이 형성되고, RTA 공정으로 제작한 시편에서는 시편 상부에 과잉 페로브스카이트 상 없이, 균일한 페로브스카이트가 형성된 것을 확인할 수 있었다. 또한 단면 미세구조에서는 RTA 공정으로 제작한 소자가 다공성 카본 전극 층에 고밀도의 페로브스카이트 층을 형성하여 우수한 광전기적 특성을 나타내었다. 따라서 대면적 소자 제작의 공정시간을 고려한 새로운 열처리방안으로 RTA 방법의 채용 가능성을 확인하였다.

Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안 (A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance)

  • 김한준;이래덕;강전흥;유광민;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

${\beta}-Ag_3SI$ 단결정막 전극에 관한 연구 (${\beta}-Ag_3SI$ Single Crystal Membrane Electrode)

  • 신두순;이선천
    • 대한화학회지
    • /
    • 제28권2호
    • /
    • pp.86-94
    • /
    • 1984
  • ${\beta}-Ag_3SI$의 단결정을 만들어 막전극으로의 응용을 살펴보았다. 그 결과 할로겐 이온들에 대해 감응함을 알았고, 분리용액법과 혼합용액법으로 할로겐 이온들에 대한 선택계수를 얻어 이론값과 비교검토 하였으며, 전위시간 곡선으로 부터 이 전극이 유리 전극기구에 의해 전도함을 알았고, 넓은 pH 범위에서 전위가 일정한 값을 가짐을 알았다. 한편 분석화학에의 응용을 살펴 본 결과 할로겐이온의 혼합용액에서 좋은 지시전극으로 사용할 수 있음을 알았다

  • PDF

습식 수중 아크용접봉의 국산화개발에 관한 기초연구 (A Basic Study on the Development of Domestic Underwater Wet Arc Welding Electrode)

  • 김민남;김복인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권5호
    • /
    • pp.1122-1129
    • /
    • 2001
  • Underwater wet arc welding process was experimentally investigated by using the six types of flux coated electrodes of 3.2 mm diameter and the KR-RA steel plate of 11 mm thickness as base metal. Two types of electrodes were domestic covered arc welding electrode(CR13, CR14) and another two types of wet welding electrodes(UWCS, TN20)were imported goods, and the other two type (UWX1, UWX2) were individually designed flux coated electrodes for experimental welding purpose. Main experimental results are summerized as follows: 1. It is ascertained that individually designed flux coated electrode(UWX1) could be used in practice with KR-RA steel plate for underwater wet arc bead welds. 2. Welding arc can be generated easily and considerably kept in stable using TN20 and UWX1 electrodes. 3. The micro Vickers hardness value and the portion of martensite in the HAZ were increased in all the electrodes by rapid cooling rate, but it is relatively maintain stable for UWCS, TN20 and UWX1 electrodes.

  • PDF

피복성분에 의한 수중용접봉의 아크 안정성 개선에 관한 실험연구 (An Experimental Study on the Arc Stability Improvement of Underwater Wet Welding with Flux Ingredients)

  • 김복인;노창석;정교헌;김민남
    • 한국해양공학회지
    • /
    • 제15권4호
    • /
    • pp.73-79
    • /
    • 2001
  • Underwater wet bead-on-plate welds were experimentally performed on 11mm thick SS400 steel plate as base metal by using six different types of flux coated electrodes of 3.2mm diameter. Two kinds of different flux coated wet arc electrodes (UW-1, UW-2) were individually designed flux materials, three kinds of the electrodes (E4301, E4311, E4313) were terrestrial electrodes and the another one (TN20) was an imported underwater wet welding electrode. As results, the individually designed flux coated underwater electrode, UW-2 and TN20 had a good starting and the excellent arc stability compared with other electrodes. No significant difference of bead appearance could be detected, but the slag detachability of TN20 electrodes was relatively undesirable. By rapid cooling rate, the hardness value and the portion of martensite of HAZ were increased, but it was considerably maintain stable for TN20 and UW-2 electrodes. The individually designed flux coated electrode, UW-2 could be used in practice for underwater bead welds.

  • PDF

Output Voltage Characteristics of HVDC Electric Field Mill Sensor for Different Speed Variables of Rotating Electrode

  • Kim, Young Sun;Park, Jae Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.2001-2006
    • /
    • 2017
  • This paper explains the effects of the weak signal of a rotating-type electric field mill sensor fabricated for measuring the intensity of the electric field generated by high-voltage direct current (HVDC) power transmission lines. The fabricated field mill consists of two isolated electrode vanes, a motor driver, and a ground part. The sensor plate is exposed to and shielded from the electric field by means of a rotary shutter consisting of a motor-driven mechanically complementary rotor/stator pair. When the uncharged sensor plate is exposed to an electric field, it becomes charged. The rotating electrode consists of several conductive vanes and is connected to the ground part, so that it is shielded. Determining the appropriate design variables such as the speed of the vane, its shape, and the distance between the two electrodes, is essential for ensuring optimal performance. By varying the speed, the weak signal characteristics which is used to signal processing and calibration experiment are quite different. Each weak signal pattern was analyzed along with the output voltage characteristics, in order to be able to determine the intensity of the electric field generated by HVDC power transmission lines with accuracy.