• Title/Summary/Keyword: Plate bearing capacity

Search Result 190, Processing Time 0.023 seconds

Study on application case of reinforce building shallow foundation for soil stabilized materials using circulating resources (순환자원 활용 지반안정재의 건축물 얕은기초 보강 적용사례 연구)

  • Song, Sang-Huwon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.457-462
    • /
    • 2022
  • This study is about the case applied of a shallow foundation reinforcement method for a low/mid-rise building where a relatively small load is applied by using a soil stabilized material that utilizes recycled resources. First, laboratory mixing test was conducted for four mixing ratios in order to derive the optimal mixing ratio in the field. Using the derived optimal mixing ratio, it was applied as a shallow foundation for the building in the field. The field application method used a simple process of compaction by the soil mixedure with the original soil and the soil stabilized material in the field. After field application, a plate bearing test was performed on one original ground and two improved ground to confirm the allowable bearing capacity. As a result of checking the bearing capacity, it was found that sufficient bearing capacity was exhibited.Therefore, it was confirmed that it can be used as a shallow foundation for the building.

Application of in-situ testing Methods for Bearing Capacity Estimation of Railroad Roadbed (철도 노반의 지지력 평가를 위한 현장 시험법 적용성 연구)

  • Park, Chang-Woo;Choi, Chan-Yong;Lee, Il-Wha;Kim, Dae-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.866-875
    • /
    • 2006
  • The field plate load test a good potential for determining modulus since it measures both plate pressure and settlement. However, because The field plate load test is expensive and takes plenty of time for operation, it is very difficult to figure out the test characteristics of railroad roadbed in detail. For faster and economical operation, the Dynamic Cone Penetrometer(DCP) and the Light Falling Weight Deflectometer(LFWD) have been utilized for estimating the bearing capacity of railroad roadbed. The objective of this study is to determine the relationship between the test(PLT, DCP, LFWD) of the railroad roadbed in Korea. The DCP test and LFWD test for evauluating the strength of railroad roadbed materials produced in Korea are presented in this paper.

  • PDF

Evaluate of bearing capacity by dynamic load in base (동하중에 의한 노상의 지지력 평가)

  • 김종렬;박달수;박정훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.279-286
    • /
    • 2002
  • Present all sorts of failure or no failure test methods are done for evaluate structural ability of pavement. It are Plane Plate Test, CBR Test, Benkelman Beam Test, FWD, Dynaflect, etc. but, each method of test not expect compatibility because the result very different by each method of test. Now among pavement's method of evaluation, no failure test gradually use because It quickly and simply obtain pavement's elastic modulus of each layer. But, It accompany expensiveness equipment, and It's degree of trust is lower against expensiveness equipment. Therefore this research practice comparative trustworthy Plane Plate Test, comparative low cost and quick Small FWD Test. And analyzed relation of Plane Plate Test with Small FWD Test.

  • PDF

Study of Ground Reinforced Effect using the Porous Geocell (다공성 지오셀을 이용한 지반 보강효과에 관한 연구)

  • Shin, Eun-Chul;Kim, Sung-Hwan;Kim, Young-Jin
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.1
    • /
    • pp.33-40
    • /
    • 2009
  • The laboratory tests and field plate load test were carried out to evaluate the reinforcement effect of geocell for road construction. The geocell-reinforced subgrade shows the increment of cohesion and friction angle with comparison of non-reinforced subgrade. In addition, the field plate load test was performed on the geocell-reinforced subgrade to estimate the bearing capacity of soil. The direct shear test was conducted with utilizing a large-scale shear box to evaluate the internal soil friction angle with geocell reinforcement. The number of cells in the geocell system is varied to investigate the effect of soil reinforcement. The theoretical bearing capacity of subgrade soil with and without geocell reinforcement was estimated by using the soil internal friction angle. The field plate load tests were also conducted to estimate the bearing capacity with geocell reinforcement. It is found out that the bearing capacity of geocell-reinforced subgrade gives 2 times higher value than that of unreinforced subgrade soil. The settlement and the distribution of deformation were also estimated by using the finite element method. The magnitude of settlements on the geocell-reinforced subgrade and unreinforced subgrade are 6.8cm and 1.2cm, respectively.

  • PDF

An Experimental Study on the Behavior of Miscopiles installed in Weathered Weak Rock (풍화암 지반에 설치된 소구경말뚝의 거동에 관한 연구)

  • 박성재;정경환;이세훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.389-396
    • /
    • 1999
  • In this study compressive and tensile load tests have been performed to investigate reinforcing effect and load transfer mechanism of small diameter piles installed in the foundation soil for the marine suspension bridge. Load tests were carried out on steel plate with diameters of 50cm, 100cm and 150cm varying loads starting from 39 tons up to 314 tons. Small diameter piles were proved to behavior like as friction piles and loads were not transmitted to the bottom of piles. From pull-out tests, the uplift capacity of small diameter piles was largely influenced by reinforcing materials compared to frictional resistance between piles and adjacent soils. The bearing capacity of small diameter piles appeared to be higher than the ultimate bearing capacity evaluated using static formulae. The load carrying capacity of small diameter piles was superior to the bored piles with a similar size. Thus, ultimate bearing capacity estimated from static formulae can provide conservative designs and thereby resulting in economic disadvantages. A further study to accumulate data regarding various soil conditions is recommended for an improved estimation of bearing capacity of piles with small diameter.

  • PDF

Experimental and numerical study on tensile capacity of composite cable-girder anchorage joint

  • Xuefei Shi;Yuzhuo Zhong;Haiying Ma;Ke Hu;Zhiquan Liu;Cheng Zeng
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.215-230
    • /
    • 2023
  • Cable-girder anchorage joint is the critical part of cable-supported bridges. Tensile-plate anchorage (TPA) is one of the most commonly used types of cable-girder anchorage joints in steel girder cable-supported bridges. In recent years, it has been proposed by bridge designers to apply TPA to concrete girder cable-supported bridges to form composite cable-girder anchorage joint (CCGAJ). In this paper, the mechanical performance of CCGAJ under tensile force is studied through experimental and numerical analyses. Firstly, the effects of the external prestressing (EP) and the bearing plate (BP) on the mechanical performance of CCGAJ were investigated through three tests. Then, finite element model was established for parametrical study, and was verified by the experimental results. Then, the effects of shear connector forms, EP, BP, vertical rebar rate, and perforated rebar rate on the tensile capacity of CCGAJ were investigated through numerical analyses. The results show that the tensile capacity of CCGAJ depends on the first row of PR. The failure mode of CCGAJ using headed stud connectors is to form a shear failure surface at the end of the studs while the failure mode using PBLs is similar to the bending of a deep girder. Finally, based on the strut-and-tie model (STM), a calculation method for CCGAJ tensile capacity was proposed, which has a high accuracy and can be used to calculate the tensile capacity of CCGAJ.

An Experimental Study on Behavior for the Piled Raft (Piled Raft 거동특성에 관한 실험적 연구)

  • Kwon, Oh-Kyun;Lee, Seung-Hyun;Oh, Se-Boong;Lim, Jong-Seok;Lee, Whoal
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.06a
    • /
    • pp.77-89
    • /
    • 2002
  • To analyze a bearing capacity for pile groups, a number of model tests have been done and theoretical methods studied. In the case of design of group pile bearing capacity is calculated with only pile capacity. But uncertainty of bearing capacity and behavior of foundation cap(raft) leads to conservative design ignoring bearing effects of foundation cap. In the case of considering bearing capacity of foundation cap, the simple sum of bearing capacity of foundation cap and pile groups cannot be the bearing capacity of total foundation system. Since cap-pile-soil interaction affects the behavior of pile groups. Thus, understanding cap-pile-soil interaction is very important in optimal design. In this paper, the piled raft behavior is studied through model tests of 2$\times$2, 2$\times$3, 3$\times$3 pile group. Changes of behavior of pile group foundation by touching effects of foundation cap with soil are studied. Also changes of spacing between piles. Foundation cap is made of rigid steel plate and piles are made steel pipes. From this model tests, the changes of behavior changes of pile groups by touching effects of foundation cap with soil are studied.

  • PDF

Evaluation of Bearing Capacity and Load Transfer Characteristics of Point Foundation(PF) Method through the Large Plate Bearing Test (대형 평판재하시험을 통한 PF 공법의 하중전이 특성 분석)

  • Kang, Min-Su;Jo, Myung-Su;Koh, Yong-Taek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.142-143
    • /
    • 2021
  • The general ground conditions in Korea are distributed in order of fill, deposit soil, weathered soil, weathered rock, soft rock. The fill soil and deposit soil located at the top have relatively low strength compared to the lower layer, and they are sometimes classified as soft ground according to the standard penetration test results. In this study, the PF method, a ground improvement method, was applied to the soft layer, a large plate load test was conducted on the improved ground, and the results were reviewed.

  • PDF

Preliminary Analysis of Stabilization of Forest Road Surface Using Geosynthetics (토목섬유를 이용한 임도 노면의 안정성 예비 분석)

  • Lee, Kwan-Hee;Oh, Se-Wook;Ko, Chi-Ung;Kim, Dong-Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.51-60
    • /
    • 2015
  • This study conducted shear strength test and plate bearing test to look into the characteristics of bearing capacity using geosynthetics case on forest road surface. The shear strength test showed that the internal friction angle at the time when geosynthetics was used was measured larger on average than that in the unreinforced case. Therefore, using geosynthetics case produced more bearing capacity reinforcement effect. The result from the comparison test of internal friction angle by geosynthetics type revealed that the internal friction angle at the time when geotextile case was used was measured larger. That was attributable to the difference between the area of the total cross section of geotextile made in type of non-woven fabric and its material. Plate bearing test showed that the settlement at the time when geosynthetics was used was measured smaller than that in the unreinforced case. Therefore, using geosynthetics produced more bearing power reinforcement effect. The result from the comparison test showed that geogrid case was measured smaller than geotextile case. Henceforth, It is seemed that it will be necessary to keep studying the reinforcement engineering and process of forest road surface which fits the characteristics and conditions of geosynthetics to prevent forest road demage.

A Study on Evaluation of Sidewalk / Roadway Pavement Using Stone Block (스톤 블럭을 이용한 보.차도 포장의 적용성 평가)

  • Yoon, Won-Sub;Kim, Jong-Kook;Park, Sang-Jun;Cho, Chul-Hyun;Chae, Young-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.259-266
    • /
    • 2008
  • Recently, the maintenance period of sidewalk pavement proposed in Ministry of Construction & Transportation to be extended by more than 10 years. Therefore it takes many interests in Durability and the maintenance. Beside sidewalk pavement, block pavement happened problems in parking and road less than 20km/hr about bearing capacity and durability, the maintenance. It interests about importance of environmentally friendly sidewalk pavement. It compared engineering characteristics about strength and durability through general pavement comparison with stone block pavement. It estimate bearing capacity in actual si-tu site and test site. It experimented plate bearing test and field density test. It verified about durability of pavement by construction availability of geosynthetics that is constructed by purpose of filter. Stone block pavement evaluated about application of sidewalk/road pavement on the basis of result.

  • PDF