• Title/Summary/Keyword: Plate Thermometer

Search Result 12, Processing Time 0.022 seconds

A Study on the Improvement of Spatial Resolution with Miniaturization of Plate Thermometer (판형 열유속계의 소형화에 따른 공간 해상도 개선에 관한 연구)

  • Yun, Hong-Seok;Han, Ho-Sik;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.39-46
    • /
    • 2019
  • This study assessed the measurement errors and improvement of the spatial resolution through miniaturization of the plate thermometer used to measure the heat flux in a fire environment. As a result, the heat loss to the side of plate thermometer was found to have a significant influence on the measurement error through analysis of the measurement values according to the thickness and density change to the insulation installed on the back side of the plate. Based on the existing 10 cm square shape, it was also confirmed that the 3 cm size plate thermometer could measure the heat flux with satisfactory accuracy through miniaturization. These results are expected to be useful for accurate measurements of the heat flux at local locations in a fire environment.

Measurement of Radiative Heat Flux Using Plate Thermometer (판열유속계를 이용한 복사열유속 측정 실험)

  • Park, Won-Hee;Yoon, Kyung-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.95-98
    • /
    • 2013
  • Plate thermometers are used for measuring the radiative heat flux in high-temperature surroundings. The heat flux is calculated from the temperature measured at the back surface of the stainless steel surface of the meter. Heat fluxes from a Schmidt-Boelter gauge are measured as reference heat fluxes. A combined conductive coefficient is introduced to consider the heat loss to insulation, conduction through the stainless plate depth, and conduction from the non-uniform temperature of the plate of the plate thermometer. This coefficient is obtained using the repulsive particle swarm optimization.

An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions (정상 및 비정상상태의 화재조건에서 판형 열유속계의 적용성에 관한 실험적 연구)

  • Yun, Hong-Seok;Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.34-41
    • /
    • 2015
  • The applicability of plate thermometer (PT), which feature simple installation and low cost, was experimentally examined in steady and unsteady-state fire conditions. An infrared radiation heater and a square burner with C3H8 as fuel were used as heat sources. The relative measurement accuracy of the PT was evaluated by comparing measurements made using a Gardon-type heat flux meter. From a practical point of view and in terms of measurement accuracy, the optimal size and thickness of the PT in steady and unsteady-state fire conditions were 100 mm and 0.6 mm, respectively. These results can be explained by the conductive heat losses and thermal inertia of the PT for different sizes and thicknesses. It can be also concluded that measurements of heat flux using the PT in conditions of faster fire growth rate than slow require considerable attention.

Infrared Temperature Monitoring System based CAN for USN (USN를 위한 CAN 기반 적외선 온도감시 시스템)

  • Kim, Young-Dong;Oh, Guem-Kon;Jeong, Won-Tae;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.11-17
    • /
    • 2007
  • RWe have developed an infrared temperature monitoring system to measure the temperature of hot iron plate in very harsh environmental conditions as iron making equipment. We performed extensive field test for 3 months at the front side of iron plate rolling process of POSCO in Gwang-Yang. From the experimental test, we have confirmed the reliability of the developed system. We adjust the curve fit method to solve the non-linearity equations of A2TPMI sensor, and establish the under $1[^{\circ}C]$precision ratio and 25[msec] process speed each range. As experimental, we have confirmed the reliability of an infrared temperature monitoring system as POSCO test result and CAN network traffic monitoring of polling method.

Study on Development of High Performance Evaporator for Automotive Air Conditioner (자동차 공조용 증발기의 고성능화에 관한 연구)

  • Kang, J.K.;Kim, K.H.;Park, T.Y.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF

Fabrication of RRR Measuring System for Disseminating IEC International Standard (IEC국제규격을 보급하기 위한 RRR측정장치 제작)

  • Kyu Won Lee;Kyu Tae Kim
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.80-85
    • /
    • 2002
  • In order to disseminate the IEC international standard of RRR measurement of Cu/Nb/-Ti composite superconductors, a measuring system was developed at KRISS. The system consisted of helium reservoir, base plate, thermometer, voltmeter and current source. The helium reservoir and base plate provided a stable temperature of a range from 4.2 K to 300 K and the voltmeter measured several order of $mutextrm{V}$ on specimen for obtaining RRR of the Cu/Nb-Ti composite superconductor. Three specimens of the Cu/Nb-Ti composite superconductors were measured using this system for characterizing their RRR. The resistance-temperature curves ortho specimens showed 10/sup -6/ to 10/sup -5/ Ohms near transition temperature and 10/sup -4/ to 10/sup -3/ Ohms at 293 K. The RRR values of the specimens were 145, 71 and 140, respectively.

  • PDF

Analysis and Improvement for Method of Boiling Point Measurement described in Middle School Science Textbooks (중학교 과학 교과서에 기술된 끓는점 측정 방법 분석 및 개선점 제안)

  • Noh, Eul;Jang, Nak Han
    • Journal of Science Education
    • /
    • v.39 no.3
    • /
    • pp.446-456
    • /
    • 2015
  • We have analyzed affecting factors of boiling point measurement and proposed to improve these after identifying errors of boiling point experiment in 7th grade science textbooks of 2009 revised curriculum. In the result of analyzing affecting factor of boiling point measurement for nine kinds of science textbooks, we have identified six affecting factors like as types of thermometer, heating instrument, sealing or not of stopper, position of thermometer, shape of container, and volume ratio of material and container. When performing experiment of boiling point measurement, we identified the best results when heating with a hot plate, positioning thermo sensor of MBL near neck branch after filling and sopping 10% volumes of material in round bottom flask. Based on this result, we have compared nine kinds of 7th grade science textbooks and found many errors that must be corrected in most of textbooks. Therefore it should be improved the experiment of science textbooks to enhance the understanding of students and to prevent from misconceptions for boiling point measurement.

  • PDF

Standardization of Critical Temperature Measurement based on IEC International Standard

  • Lee, Kyu-Won;Kim, Kyu-Tae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.123-127
    • /
    • 2003
  • For disseminating a ney IEC international standard of critical trmperature of NbTi,Nb$_3$Sn and Bi-2223 Composite Suterconductors, we develpted a measuring system and studied standardization of test method. The measuring system consisted of cryogenic reservoir, base plate, thermometer, voltmeter and current source. Various specimens of the Nbti, Nb$_3$Sn and Bi-2223 composite superconductors were tested using this system for measuring their critical temperatures. After measuring the resistance-temperature relation, the data were compensated with thermoelectric voltages for NbTi Nb$_3$Sn specimens. NbTi specimens showed 9.2 K ~ 9.5 K of transition temperature and Nb$_3$Sn specimen showed about 18 K. Bi-2223 specimens showed 104 K ~ 107 K of transition temperature.

Tribological Characteristics for High Perfomance Metallic Friction Materials (고성능 금속마찰재의 트라이볼로지적 특성)

  • 김석삼;김재호;안효준
    • Tribology and Lubricants
    • /
    • v.14 no.1
    • /
    • pp.45-53
    • /
    • 1998
  • Friction and wear test for two kinds of Cu-based sintered metallic friction material against cast iron disk was carried out by plate-on-disk type friction and wear tester to investigate the friction and wear characteristics of brake system in severe condition. In this experimental study, the counter specimen was cast iron which is being used generally in brakes of heavy duty equipments. Test friction materials were A type which was manufactured by foreign company and B type by domestic company. Friction coefficient and wear volume were measured and compared with each other. The experiment was performed under room temperature. The worn surface of cast iron disk and friction material were observed by scanning electron microscope. The temperature of surface of disk was measured continuously by the non-contacting thermometer. It was found that A type friction material had stable friction coefficient over the wide range of sliding condition, but B type friction material had unstable friction coefficient and lower value of 0.2 under the severe sliding condition.

The study to flat-type generate of magnetic field with CW (Continue wave) frequency and AM (Amplitude modulation) frequency

  • Shin, Gi Won;Kang, Chang Ho;Lee, Min Jun;Yang, Sung Jae;Lee, Hyuk Ho;Hong, Hyun Bin;Jo, Tae Hoon;Kwon, Gi Chung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.139.2-139.2
    • /
    • 2015
  • In this study, We applied the magnetic field that has CW frequency and AM frequency to heating magnetic nano powder. For this experiment, We set up the devices flat-type magnetic field generator with CW frequency and AM frequency. We supplied the current to encircling coil by adjusting the power of generating of magnetic field device for AC voltage through Slidacs and using way of LC resonance circuit and SMPS(Switching Mode Power Supply). Above the encircling coil, We covered the circular flat insulator like glass. And we located the well plate containing the magnetic nano powder liquor above the circular flat insulator and exposed the magnetic field to this well plate. Using the flat-type magnetic field generator with CW and AM frequency and the magnetic field measurement sensor(Magnetic pick up coil or Hall sensor), We measured the strength of the magnetic field of circular flat insulator's surface in each position. The temperature of the magnetic nano powder in the well plate was quantitatively measured by the magnetic field strength through the Fluoroptic thermometer.

  • PDF