• 제목/요약/키워드: Plastic sensor

검색결과 171건 처리시간 0.027초

A Study on the Flow Field Characteristics of Air Induction System for Reducing the Signal-to-Noise in the MAFS Output

  • 유성출
    • 한국분무공학회지
    • /
    • 제5권1호
    • /
    • pp.49-57
    • /
    • 2000
  • This study presents the flow visualization results, velocity and turbulence intensity measurements made within an air filter cover and entry region of a mass air flow sensor (MAFS) which is used in an induction system of 3.8L engine. Flow structure in two air filter cover assemblies were examined. The first was a clear plastic replica of the production cover while the second was a modified clear plastic cover with a geometry configured to reduce fluctuations. High speed flow visualization and laser doppler velocimetry (LDV) systems were used to reveal and analyze the flow field characteristics encountered in the sensor design process under steady flow conditions. A 40-watt copper vapor laser was used as a light source. Its beam is focused down to a sheet of light approximately 1.5mm thick. The light scattered off the particles was recorded by a 16mm high speed rotating prism camera at 5000 frames per second. A comparison of the flow patterns and LDV measurements in the original and modified air filter covers is presented to illustrate the controlling effect of the cover design on the turbulence structure formation near the bypass and on the sensor output signal. In both axial and radial planes of the main passage it was found that the turbulence flow pattern is remarkably influenced by the air filter cover and main passage configuration.

  • PDF

Development of Single-layer-structured Glucose Biosensor

  • Lee, Young-Tae;Kwon, Min Su
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.83-87
    • /
    • 2015
  • In this paper, we fabricated a low-cost glucose sensor with a simpler structure and fabrication process than the existing glucose sensor. The currently used glucose sensor has a three-layer structure with upper, middle, and bottom plates; here, we fabricated a single-layer glucose sensor using only a printing and dispensing process. We successfully fabricated the glucose sensor using a simple method involving the formation of an electrode and insulator layer through a 2- or 3-step printing process on plastic or paper film, followed by the dispensing of glucose oxidase solution on the electrode. Cyclic voltammetry (CV) and cyclic amperometry (CA) measurements were used to evaluate the characteristics of the fabricated single-layer glucose sensor. Also, its sensitivity was analyzed through glucose-controlled blood measurements. Hence, a low-cost single-layer glucose sensor was fabricated with evaluation of its characteristics demonstrating that it has useful application in medicine.

Influence of Negative-Pressure Wound Therapy on Tissue Oxygenation of the Foot

  • Shon, Yoo-Seok;Lee, Ye-Na;Jeong, Seong-Ho;Dhong, Eun-Sang;Han, Seung-Kyu
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.668-672
    • /
    • 2014
  • Background Negative-pressure wound therapy (NPWT) is believed to accelerate wound healing by altering wound microvascular blood flow. Although many studies using laser Doppler have found that NPWT increases perfusion, recent work using other modalities has demonstrated that perfusion is reduced. The purpose of this study was to investigate the influence of NPWT on tissue oxygenation of the foot, which is the most sensitive region of the body to ischemia. Methods Transcutaneous partial pressure of oxygen ($TcpO_2$) was used to determine perfusion beneath NPWT dressings of 10 healthy feet. The sensor was placed on the tarso-metatarsal area of the foot and the NPWT dressing was placed above the sensor. $TcpO_2$ was measured until it reached a steady plateau state. The readings obtained at the suction-on period were compared with the initial baseline (pre-suction) readings. Results $TcpO_2$ decreased significantly immediately after applying NPWT, but gradually increased over time until reaching a steady plateau state. The decrease in $TcpO_2$ from baseline to the steady state was 2.9 to 13.9 mm Hg (mean, $9.3{\pm}3.6$ mm Hg; $13.5{\pm}5.8%$; P<0.01). All feet reached a plateau within 20 to 65 minutes after suction was applied. Conclusions NPWT significantly decrease tissue oxygenation of the foot by 2.9 to 13.9 mm Hg. NPWT should be used with caution on feet that do not have adequate tissue oxygenation for wound healing.

Hybrid FRP Rod로 보강된 철근콘크리트 보의 휨 거동 (Flexural Behavior of Reinforced Concrete Beam with Hybrid FRP Rods)

  • 곽계환;장화섭;양동운
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.327-330
    • /
    • 2005
  • In this study, the nature of brittleness, one of the main problems of GFRP(Glass Fiber Reinforced Plastic) Re-bar, is improved. Therefore, Hybrid GFRP Rod is developed by attaching FBG sensor to the new GFRP Rod with toughness, essential for flexural reinforcement of the concrete. The test was performed with specimens of Hybrid GFRP Rod. According to the test, data measured by electric gauge sensor are compared with data measured by FBG sensor.

  • PDF

LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발 (Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy)

  • 한기택;유욱재;신상훈;전다영;박장연;박병기;이봉수
    • 센서학회지
    • /
    • 제21권4호
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.

센서 융합형 지능형 부품 제조를 위한 적층 제조 기술 연구 (Additive Manufacturing for Sensor Integrated Components)

  • 정임두;이민식;우영진;김경태;유지훈
    • 한국분말재료학회지
    • /
    • 제27권2호
    • /
    • pp.111-118
    • /
    • 2020
  • The convergence of artificial intelligence with smart factories or smart mechanical systems has been actively studied to maximize the efficiency and safety. Despite the high improvement of artificial neural networks, their application in the manufacturing industry has been difficult due to limitations in obtaining meaningful data from factories or mechanical systems. Accordingly, there have been active studies on manufacturing components with sensor integration allowing them to generate important data from themselves. Additive manufacturing enables the fabrication of a net shaped product with various materials including plastic, metal, or ceramic parts. With the principle of layer-by-layer adhesion of material, there has been active research to utilize this multi-step manufacturing process, such as changing the material at a certain step of adhesion or adding sensor components in the middle of the additive manufacturing process. Particularly for smart parts manufacturing, researchers have attempted to embed sensors or integrated circuit boards within a three-dimensional component during the additive manufacturing process. While most of the sensor embedding additive manufacturing was based on polymer material, there have also been studies on sensor integration within metal or ceramic materials. This study reviews the additive manufacturing technology for sensor integration into plastic, ceramic, and metal materials.

광섬유 pH 센서 개발을 위한 분광학적 연구 (Spectroscopic study on the development of fiber-optic pH sensor)

  • 유욱재;허지연;조동현;장경원;서정기;이봉수;조영호;문주현;박병기
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.365-371
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic pH sensor which is composed of a light source, plastic optical fibers and a spectrometer. As an indicator, a phenol red is used, and a pH liquid solution is prepared by mixing of phenol red and various kinds of pH buffer solutions in these experiments. The emitting light from a light source is guided by plastic optical fibers to the pH liquid solution, and the optical characteristic of a light is changed in the pH liquid solution according to its color change. Therefore, we have measured the intensities and wavelength shifts of the modulated lights, which are changed due to the color variations of phenol red at different pH values, by using of a spectrometer for spectral analysis. Also, the relationships between the pH values of liquid solutions and the optical properties of modulated light according to the change of color of phenol red are obtained.

초정밀 사출렌즈 금형 기술 (Mold Technology for Precision Injection Lens)

  • 하태호;조형한;송준엽;전종
    • 한국정밀공학회지
    • /
    • 제31권7호
    • /
    • pp.561-567
    • /
    • 2014
  • Precision injection mold is an essential element in order to manufacture small and precision plastic lenses used for phone camera. There are many critical factors to meet the requested specifications of high quality plastic lenses. One of the main issues to realize high quality is minimizing decenter value, which becomes more critical as pixel numbers increases. This study suggests the method to minimize decenter value by modifying ejecting structure of the mold. Decenter value of injection-molded lens decreased to 1 ${\mu}m$ level from 5 ${\mu}m$ by applying suggested ejecting method. Also, we also developed BIS (Built-in Sensor) based smart mold system, which has pressure and temperature sensors inside of the mold. Pressure and temperature profiles from cavities are obtained and can be used for deduction of optimal injection molding condition, filling imbalance evaluation, status monitoring of injection molding and prediction of lens quality.

플라스틱 자석 혼합물의 균질도 평가방법과 균질도가 자기특성에 미치는 영향 (Evaluation Methods of Homogeneity for Feedstocks and Effect of Homogeneity on the Magnetic Properties of Plastic Magnets)

  • 이석희;최준환;문탁진;정원용
    • 한국자기학회지
    • /
    • 제8권2호
    • /
    • pp.86-92
    • /
    • 1998
  • 플라스틱 자석에는 균일한 자장분포와 높은 자기특성을 얻기 위해서는 균질화된 혼합물이 요구되며, 이를 위해서는 적절한 혼합경로와 혼합물의 균질도 평가방법이 필수적이다. 본 연구에서는 Sr-ferrite/EVA 플라스틱 자석에서 혼합균질도의 평가방법과 혼합균질도가 자기특성에 미치는 영향을 조사하였다. 회분식 혼합기와 단축압출기를 이용하여 균질도가 서로 다른 혼합균질도를 조사하였다. 토크센서를 이요한 혼합시 토크변화 측정방법은 임계분말충전율 결정에는 효과적인데 반해 혼합균질도 평가에는 적합하지 않았다. 이그이방성 플라스틱 자석의 분말이방화율을 이용한 균질도 평가방법은 정밀도는 높으나, 시편제조와 측정에 고가의 장비와 필요하고 자성분말 혼합물 이외에는 이용될수 없다. 모세관 레오미터를 이용한 압출압력변화 측정방법은 정밀도가 높고 측정이 간편하여 효과적이었다. 혼합물의 균질도가 증가함에 따라 분말이방화율이 증가하였으며, 분말이방화율의 증가에 따라 잔류자속밀도는 직선적으로 증가하였다.

  • PDF

초음파센서를 이용한 로봇의 소형장애물 감지 및 회피방법연구 (Perception of small-obstacles using ultrasonic sensors and its avoidance method in robot)

  • 김갑순
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.101-108
    • /
    • 2005
  • The research on the avoidance of the large-obstacles such as a wall, a large box, etc. using ultrasonic sensors has been generally progressed up to now. But the mobile robot could meet a small-obstacle such as a small plastic bottle, a small sphere, and so on in its designated path, and could be disturbed by them in the locomotion of the mobile robot. So, it is necessary to research on the avoidance of a small-obstacle. In this paper, a robot's small-obstacle perceiving system was designed and fabricated by arranging four ultrasonic sensors on the plastic plate to avoid small-obstacles. The system was installed on the upper part of the mobile robot with the slope angles between $40.7^{\circ}$ and $23.3^{\circ}$ to a horizontal line and the dynamic characteristic test of the robot was performed. As the result, it was confirmed that the mobile robot with the system could avoid small-obstacles in indoor environment safely.