Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy |
Han, Ki-Tek
(School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University)
Yoo, Wook-Jae (School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University) Shin, Sang-Hun (School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University) Jeon, Da-Yeong (School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University) Park, Jang-Yeon (School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University) Park, Byung-Gi (Department of Energy & Environment Engineering, College of Engineering, Soonchunhyang University) Lee, Bong-Soo (School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University) |
1 | K. W. Jang, D. H. Cho, W. J. Yoo, J. K. Seo, J. Y. Heo, B. Lee, S. H. Shin, B. G. Park, and S. Kim, "Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter", J. Kor. Sensors Soc., vol. 19, no. 1, pp. 52-57, 2010. |
2 | J. H. Jang, B. J. Kim, K. S. Cho, and G. D. Kim, "Development of real-time thickness measuring system for insulated pipeline using gamma-ray", J. Korean Soc. Nondestructive Test, vol. 22, no. 5, pp. 500-507, 2002. |
3 | H. B. Coakham and J. T. Kemshead, "Treatment of neoplastic meningitis by targeted radiation using 131I-radiolabelled monoclonal antibodies", J. Neuro-Oncol., vol. 38, pp. 225-232, 1998. DOI |
4 | A. S. Beddar, T. J. Kinsella, A. Ikhlef, and C. H. Sibata, "A miniature 'Scintillator-Fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery", IEEE Trans. Nucl. Sci., vol. 48, pp. 924-928, 2001. DOI ScienceOn |
5 | S. H. Shin, K. W. Jang, W. J. Yoo, J. K. Seo, B. Lee, J. H. Moon, S. Kim, and B. G. Park, "Measurement of relative depth dose rates for a brachytherapy Ir-192 source using an organic scintillator fiber-optic radiation sensor", J. Kor. Sensors Soc., vol. 17, no. 6, pp. 462-469, 2008. |
6 | K. W. Jang, D. H. Cho, S. H. Shin, W. J. Yoo, J. H. Jeon, B. Lee, J. H. Moon, and B. G. Park, "Fabrication and characterization of a onedimensional fiber-optic dosimeter for electron beam therapy dosimetry", J. Kor. Sensors Soc., vol. 19, no. 4, pp. 285-290, 2008. |