• Title/Summary/Keyword: Plastic sensor

Search Result 171, Processing Time 0.023 seconds

Plastic Optical Fiber Sensor for an Anti-Drowsy Driving (운전자 졸음 방지용 플라스틱 광섬유 센서)

  • Eom, Won-Dae;Yeo, Sang-Du;Park, Jae-Hee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.133-139
    • /
    • 2008
  • In this paper, the feasibility for producing a plastic optical fiber sensor to be used as an anti-drowsy driving sensor is discussed. This sensor consists of a plastic optical fiber wound on the steering wheel covered by soft material. When a driver hold a steering wheel, the gripping force is induced and causes to the bend of the plastic optical fiber which decreases the power of light propagated inside the plastic fiber. The experimental results show that the detected optical power decrease as the gripping force increase and that this sensor can be used as the anti-drowsy driving sensor.

  • PDF

Impaction of a continuous glucose monitoring sensor

  • Park, Kyong Chan;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.392-394
    • /
    • 2021
  • A 33-year-old man presented to the plastic surgery department for foreign body removal 1 month after the insertion of a continuous glucose monitoring (CGM) sensor (Dexcom G5) in the left upper arm. The patient had used the CGM system for 5 years, and the insertion was done in the usual manner. The entire sensor wire was visible on simple radiography and ultrasonography. In the operating room, and the sensor wire was identified in the intermuscular septum and removed. No foreign body reaction or inflammatory signs were found around the CGM, and the extracted wire measured 2.5 cm. Thus, it was assumed that the whole sensor wire was detached from the transmitter, not fractured. No remnant foreign body was observed on follow-up simple radiography.

Development of Plastic Film Type Submersion Sensor (플라스틱 필름형 침수센서 개발)

  • Lee, Young Tae;Kwon, Ik Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.107-111
    • /
    • 2022
  • In this paper, a plastic film type submersion sensor capable of measuring submersion speed was developed. This submersion sensor is designed as a capacitive type, and it is a sensor that outputs the change in capacitance between the electrode of the submersion sensor and the grounded body as a voltage through a C-V(capacitance-voltage) converter. We developed an submersion sensor in which two electrodes of different lengths are connected in parallel to measure the submersion speed accurately by minimizing the influence of noise such as contamination. When both electrodes of the submersion sensor are exposed to water, the rate of change of water level suddenly increases, so the submersion speed is measured by measuring the time to this point. Since the difference in length between the two electrodes of the submersion sensor does not change in any case, it is possible to accurately measure the submersion speed.

Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material (무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Lee, Bong-Soo;Cho, Hyo-Sung;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.

Sensor Mat using POF for Medical Application (의료용 플라스틱광섬유 센서 매트)

  • Choi, Kyoo-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.363-365
    • /
    • 2007
  • Novel concept of sensor mat and its signal processing method is proposed for patient monitoring in medical application. Proposed sensor mat structure has sensing inner layer which has cross-linked arrangement using plastic optical fiber(POF). Large core diameter of plastic optical fiber behaved as band pass filter by averaging the noise component. caused by unwanted environmental factors. Signal processor followed by sensor output added noise immune performance by filtering out unwanted component. Fail-proof patient breath monitoring scheme was realized by using intelligent decision algorithm. Unlike the conventional approach by using mechanical sensor, which have high sensitivity both to intruder and to environmental noise, our approach provided reliable breath motion detection.

  • PDF

Fabrication of an Inkjet-printed Plastic Force Sensor Using PEDOT:PSS (PEDOT:PSS를 이용한 잉크젯 프린팅 방식 플라스틱 힘 센서 개발)

  • Lee, Wanghoon;Son, Sun-Young;Koo, Jungsik;Yeom, Se-Hyuk
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.390-394
    • /
    • 2019
  • This paper presents an inkjet-printed plastic force sensor using PEDOT:PSS. Using a piezoelectric-type inkjet printer, the force sensor was manufactured by printing PEDOT:PSS ink onto a polyimide (PI) substrate film. Applying a vertical force of 0 to 100 N to the force sensor on the PI substrate with a thickness of 64 mm, the resistance of the force sensor increased in proportion to the input force by the length deformation of the PI substrates and the sensor pattern. As a result, the fabricated sensor has a characteristic of 0.001% /N with a linearity of 99.38%. In addition, as the thickness of the PI substrate film increased, the sensitivity of the sensor increased linearly. The fabricated force sensor is expected to be applied to industrial sites and healthcare fields.

Arc-Flash Detection Sensor Based on Surface Coupling of Plastic Optical Fiber (플라스틱 광섬유 표면 입사 현상을 이용한 아크플래시 검출 광센서)

  • Jeong, Hoonil;Kim, Myoung Jin;Kim, Young Ho;Kim, Youngwoong;Rho, Byung Sup
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.208-212
    • /
    • 2016
  • In this work, a loop sensor for Arc-Flash detections has been developed in order to trip a circuit breaker within 2.5 ms after an Arc-Flash event. For an efficient capturing of the flash light, plastic optical fibers, where light attenuations are larger than those in silica-based ones, with different diameters and surface conditions were utilized. The performance was comparatively analyzed with those of a point sensor and a commercialized product. The point sensor module was designed for hemisphere-like capturings of Arc-Flashes larger than 3 kA at 2 meters from the sensor. On the other hand, the loop sensor allowed 360-degree-detections around the fiber axis and the measurement range was dependent on the length of the fiber connected to the sensor module. The trip-level-dependent brightness measurement results showed that the fabricated point sensor and loop sensor satisfied a brightness condition, 10~40 klux, and the responses of the system to Arc-Flashes were completed within 2.5 ms.

Liquid Refractive Index Sensor Based on Cladded Plastic Optical Fiber Taper (클래딩이 있는 플라스틱 광섬유 테이퍼를 이용한 용액 굴절률 센서)

  • Kim, Kwang-Taek;Kim, Hoe-Man;Yun, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.151-155
    • /
    • 2012
  • We have investigated a refractive index sensor based on a cladded plastic optical fiber taper. The optical transmission and sensing characteristics of the device were illuminated in terms of ray optics. The sensor devices showed that the optical transmittance strongly depends on the refractive index of the external medium surrounding the tapered region.

In Line Plastic-Optical-Fiber Temperature Sensor

  • Seo, Hyejin;Shin, Jong-Dug;Park, Jaehee
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.238-242
    • /
    • 2021
  • In this paper, we present an in line plastic-optical-fiber (POF) temperature sensor based on intensity modulation. The in line POF temperature sensor is composed of a POF, including an in-fiber micro hole filled with reversible thermochromic material, the transmittance of which depends on temperature. The reversible thermochromic material was cobalt chloride/polyvinyl butyral gel. A cobalt chloride solution of concentration 30.8 mM was formulated using 10% water/90% ethanol (v/v) solution, and gelled by dissolving polyvinyl butyral in this solution. Four types of in line POF sensors, with in line micro holes of four different diameters, were fabricated to measure temperature in the range of 25 to 75 ℃. The output optical power of all of these in line POF temperature sensors was inversely proportional to the temperature; the relation between output power and temperature was approximately linear, and the sensitivity was proportional to the diameter of the in-fiber micro hole. The experimental results indicate that an in line POF sensor can be used effectively for measuring moderate temperatures.

Capacitive sensor for the detection of residual quantity of intravenous drip solution in a plastic intravenous bag

  • Wei, Qun;Woo, Sang-Hyo;Mohy-Ud-Din, Zia;Kim, Dong-Wook;Won, Chul-Ho;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.271-277
    • /
    • 2010
  • Intravenous(IV) drip therapy is extensively used for all kinds of treatments. It works by delivering medicine directly into the vein. When the medicine has been fully dispensed, a dangerous situation occurs since air in the IV drip bag could enter the patient's vein, which is hazardous to the patient’s safety. In this paper, using capacitive sensors to detect the residual quantity of a plastic IV drip pack is proposed. A simulation model of this technology was shown by a finite elements analysis(FEA) program to find out its feasibility and analyze the proper geometrical dimension of a capacitive sensor. According to the FEA simulation, 3 kinds of capacitive sensors were attached to the bottom surface of the plastic IV drip bag to detect the residual quantity in the experiment. Experimental data showed an agreement with the FEA simulation model estimation and confirmed that the sensor works.