• 제목/요약/키워드: Plastic Stability

검색결과 599건 처리시간 0.026초

생활계 폐합성수지 물질 재활용 제품의 생산시기별 품질 특성 (Quality Characteristics According to the Production Period of Products Obtained by Recycling Household Plastic Waste Materials)

  • 강혜주;신성철;강석표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.167-168
    • /
    • 2020
  • In order to expand the material recycling of waste plastics made of composite materials, it is necessary to develop the use of material recycling products and to secure their quality stability. In this paper, as a basic study to secure the stability of the quality of household waste plastic material recycling products, the quality characteristics of recycled materials according to the production period were compared and reviewed. In addition, the average tensile strength of the recycled products by production period for 4 months was 12.33 MPa, and the average density was 1.35 g/m3.

  • PDF

여러 가지 가교제가 인체 무세포진피의 안정성에 미치는 영향 (Effects of Cross-Linking Agents on the Stability of Human Acellular Dermal Matrix)

  • 강낙헌;윤영묵;우종설;안재형;김진영
    • Archives of Plastic Surgery
    • /
    • 제35권3호
    • /
    • pp.248-254
    • /
    • 2008
  • Purpose: Human acellular dermal matrix(ADM) is widely used in the treatment of congenital anomalies and soft tissue deficiencies. But it is rapidly degraded in the body and does not provide satisfactory results. There is a need to improve collagen fiber stability through various methods and ultimately regulate the speed of degradation. Methods: The ADMs were added with various cross-linking agents called glutaraldehyde, dimethyl 3,3'-dithiobispropionimidate to produce cross-linked acellular dermal matrices. 1,4-butanediol diglycidyl ether solution was applied with a pH of 4.5 and 9.0, respectively. The stability of cross-linked dermal matrix was observed by measuring the shrinkage temperature and the degradation rates. The cross- and non-cross linked dermis were placed in the rat abdomen and obtained after 8, 12 and 16 weeks. Results: The shrinkage temperature significantly increased and the degradation rate significantly decreased, compared to the control(p<0.05). All of cross-linked dermises were observed grossly in 16 weeks, but most of non-cross linked dermis were absorbed in 8 weeks. Histologically, the control group ADM was found to have been infiltrated with fibroblasts and most of dermal stroma were transformed into the host collagen fibers. However, infiltration of fibroblasts in the experiment was insignificant and the original collagen structure was intact. Conclusion: Collagen cross-linking increases the structural stability and decreases degradation of acellular dermis. Therefore, decrease in body absorption and increase in duration can be expected.

An elasto-plastic damage constitutive model for jointed rock mass with an application

  • Wang, Hanpeng;Li, Yong;Li, Shucai;Zhang, Qingsong;Liu, Jian
    • Geomechanics and Engineering
    • /
    • 제11권1호
    • /
    • pp.77-94
    • /
    • 2016
  • A forked tunnel, as a special complicated underground structure, is composed of big-arch tunnel, multi-arch tunnel, neighborhood tunnels and separate tunnels according to the different distances between two separate tunnels. Due to the complicated process of design and construction, surrounding jointed rock mass stability of the big-arch tunnel which belongs to the forked tunnel during excavation is a hot issue that needs special attentions. In this paper, an elasto-plastic damage constitutive model for jointed rock mass is proposed based on the coupling method considering elasto-plastic and damage theories, and the irreversible thermodynamics theory. Based on this elasto-plastic damage constitutive model, a three dimensional elasto-plastic damage finite element code (D-FEM) is implemented using Visual Fortran language, which can numerically simulate the whole excavation process of underground project and perform the structural stability of the surrounding rock mass. Comparing with a popular commercial computer code, three dimensional fast Lagrangian analysis of continua (FLAC3D), this D-FEM has advantages in terms of rapid computing process, element grouping function and providing more material models. After that, FLAC3D and D-FEM are simultaneously used to perform the structural stability analysis of the surrounding rock mass in the forked tunnel considering three different computing schemes. The final numerical results behave almost consistent using both FLAC3D and D-FEM. But from the point of numerically obtained damage softening areas, the numerical results obtained by D-FEM more closely approach the practical behaviors of in-situ surrounding rock mass.

플라스틱 디스크상의 부상형 광헤드의 부상안정성에 관한 연구 (A Study on the Flying Stability of Optical Flying Head on the Plastic Disks)

  • 김수경;윤상준;최동훈;이승엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.399-402
    • /
    • 2004
  • 착탈식의 플라스틱 디스크와 부상형 광헤드를 사용하는 광드라이브에서 부상형 광헤드의 부상안정성 문제는 고밀도 표면기록의 신뢰성 확보를 위해 매우 중요한 요소로 고려되어야 한다. 플라스틱 디스크와 광헤드의 포커싱 제어를 위해 부상형광헤드의 광학적 조립오차와 플라스틱디스크의 보호층의 오차를 보상해주는 추가적인 엑츄에이터의 몇 가지 설계방안에 대해 검토한다. 또한 본 논문에서는 부상형 광헤드의 부상안정성을 위하여 디스크의 굴곡에 대한 부상특성과 안정성을 해석하고, 특히 로드/언로드 시의 부상안정성에 대해서도 검토해 본다.

  • PDF

Elasto-plastic stability of circular cylindrical shells subjected to axial load, varying as a power function of time

  • Sofiyev, A.H.;Schnack, E.;Demir, F.
    • Structural Engineering and Mechanics
    • /
    • 제24권5호
    • /
    • pp.621-639
    • /
    • 2006
  • Stability of a cylindrical shell subject to a uniform axial compression, which is a power function of time, is examined within the framework of small strain elasto-plasticity. The material of the shell is incompressible and the effect of the elastic unloading is considered. Initially, employing the infinitesimal elastic-plastic deformation theory, the fundamental relations and Donnell type stability equations for a cylindrical shell have been obtained. Then, employing Galerkin's method, those equations have been reduced to a time dependent differential equation with variable coefficient. Finally, for two initial conditions applying a Ritz type variational method, the critical static and dynamic axial loads, the corresponding wave numbers and dynamic factor have been found. Using those results, the effects of the variations of loading parameters and the variations of power of time in the axial load expression as well as the variations of the radius to thickness ratio on the critical parameters of the shells for two initial conditions are also elucidated. Comparing results with those in the literature validates the present analysis.

플라스틱 섬유재와 슬래그 시멘트를 이용한 고강도 간격재의 개발 및 적용성 평가 (Applicability Evaluation and Development of High Strength Spacer with Plastic Fiber and Slag Cement)

  • 권성준;조홍준;박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.92-98
    • /
    • 2014
  • 본 연구는 환경부하 저감을 위해 슬래그 시멘트를 사용하고 플라스틱 섬유보강재(폴리프로필렌, 나일론, 유리섬유)를 혼입하여 고강도 간격재를 개발하고 현장적용성을 평가하는 연구이다. 이를 위해 예비실험을 통하여 4가지 섬유 복합재의 첨가량이 결정되었다. 또한 역학적 시험(압축, 휨, 인장) 및 내구성 시험(흡수율, 투수율, 길이변화율, 균열저항성, 탄산화, 동결융해)을 통하여 최적의 섬유재를 도출하였으며, 이를 이용한 고강도 섬유재 간격재의 배합 및 생산시스템을 개발하였다. 또한 현장적용성 평가를 통하여 개발된 간격재의 구체 콘크리트 일체성을 확인하였다.

3종의 임프란트 형태에 관한 연구 (THE STUDY ON THE IMPLANT GEOMETRY)

  • 이용찬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권2호
    • /
    • pp.245-252
    • /
    • 1996
  • The purpose of this study was to develop the implant which has superior stress distribution and primary stability to others by using Instron test and finite element method. The model used in the experiment were cylinder type implant, tapered screw type implant, screw type implants. Recognizing that the number of samples were small and the lack of applying press-fit conditions to the cylinder type, we can make the following conclusions.

  • PDF

Silicon Thin-Film Transistors on Flexible Polymer Foil Substrates

  • Cheng, I-Chun;Chen, Jian Z.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1455-1458
    • /
    • 2008
  • Amorphous silicon (a-Si:H) thin-film transistors (TFTs) are fabricated on flexible organic polymer foil substrates. As-fabricated performance, electrical bias-stability at elevated temperatures, electrical response under mechanical flexing, and prolonged mechanical stability of the TFTs are studied. TFTs made on plastic at ultra low process temperatures of $150^{\circ}C$ show initial electrical performance like TFTs made on glass but large gate-bias stress instability. An abnormal saturation of the instability against operation temperature is observed.

  • PDF

Tight adhesion of plastic substrates for cell gap stability in flexible LCDs

  • Jin, Min-Young;Kim, Sang-Il;Souk, Jun-Hyung;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.78-81
    • /
    • 2008
  • We developed tight adhesion techniques of two plastic substrates to maintain cell gap stability for rugged flexible LCDs. By combining rigid spacers and several adhesion materials, we demonstrated mechanically very stable flexible LCDs against pressure and bending.

  • PDF

플레이트의 소성변형 과정이 재건술에서 플레이트 안정성에 미치는 영향 (On the Stability of the Permanently Bent Mini-plate in Reconstructive Surgery)

  • 박시명;이득희;노건우
    • 한국CDE학회논문집
    • /
    • 제21권3호
    • /
    • pp.234-241
    • /
    • 2016
  • Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shape without plastic deformation through the finite element analysis(FEA). First we simulate the process of plate bending to fit the defect in patient. Then, the other plate is modelled to represent a customized plate with the same shape of the plastically deformed one, but without any residual stresses from plastic deformation. After binding these plates to the mandible, we conduct the masticatory simulation. Finally, we compare the resulting Von Mises stress of the customized plate and of the bent plate. The bent plate shows much higher stress than the customized one due to the residual stresses form the bending process. The study shows that plastic deformation in the plate may decrease the safety of the reconstruction surgery.