• Title/Summary/Keyword: Plastic Film

Search Result 910, Processing Time 0.033 seconds

Evaluation of Interface Shear Properties Through Static Friction Tests (정적마찰 시험을 통한 접촉전단 특성평가)

  • Chang, Yong-Chai;Lee, Seung-Eun;Seo, Ji-Woong;Bowders, John J.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.813-818
    • /
    • 2009
  • Shear properties of plastic bottle film/plastic bottle film and plastic bottle film/granitic soil which were evaluated from static friction tests. The monotonic shear experiments were performed by using an tilt table apparatus and large direct shear device. The test results showed that the friction angle of each interface and the interface depended on the amount of normal stress, the type of the interface used. Therefore, the testing method should be determined carefully by considering the type of loads and normal stress expected in the field with using the materials installed in the site.

  • PDF

Fabrication of Ultra Low Temperature Poly crystalline Silicon Thin-Film Transistors on a Plastic Substrate (고분자 기판 상에 제작된 극저온 다결정 실리콘 박막 트랜지스터에 관한 연구)

  • Kim, Yong-Hoon;Kim, Won-Keun;Moon, Dae-Gyu;Han, Jeong-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.445-446
    • /
    • 2005
  • This letter reports the fabrication of polycrystalline silicon thin-film transistors (poly-Si TFT) on flexible plastic substrates using amorphous silicon (a-Si) precursor films by sputter deposition. The a-Si films were deposited with mixture gas of argon and helium to minimize the argon incorporation into the film. The precursor films were then laser crystallized using XeCl excimer laser irradiation and a four-mask-processed poly-Si TFTs were fabricated with fully self-aligned top gate structure.

  • PDF

Development of Plastic Film Type Submersion Sensor (플라스틱 필름형 침수센서 개발)

  • Lee, Young Tae;Kwon, Ik Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.107-111
    • /
    • 2022
  • In this paper, a plastic film type submersion sensor capable of measuring submersion speed was developed. This submersion sensor is designed as a capacitive type, and it is a sensor that outputs the change in capacitance between the electrode of the submersion sensor and the grounded body as a voltage through a C-V(capacitance-voltage) converter. We developed an submersion sensor in which two electrodes of different lengths are connected in parallel to measure the submersion speed accurately by minimizing the influence of noise such as contamination. When both electrodes of the submersion sensor are exposed to water, the rate of change of water level suddenly increases, so the submersion speed is measured by measuring the time to this point. Since the difference in length between the two electrodes of the submersion sensor does not change in any case, it is possible to accurately measure the submersion speed.

Image of Plastic Surgeons and Plastic Surgery Illustrated in Korean Movies and TV Dramas (한국 영화와 드라마에 나타난 성형외과 의사와 성형수술의 이미지)

  • Kim, Han Joon;Hwang, Kun
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.95-98
    • /
    • 2012
  • Nowadays, plastic surgical operations are increasingly being performed in Korea. We have gained added interest in this because some professional pictures contain plastic surgery in their venue. In the films, we intend to see the recognition of society for plastic surgeons and which field of plastic surgery. The list of movies for analysis were 'Plastic Beauty (1975)', 'Penthouse Elephant (2005)', '200 Pounds Beauty (2006)', 'Cinderella (2006)', and 'Time (2006)'. The TV dramas were 'She is looking (2005)', 'Lovers (2006-2007)', and 'Before & After Plastic Surgery Clinic (2008)'. Films were analyzed according to the following: the chief complaints and names of the operations, character of plastic surgeons, result of the operation and its possibility in reality, and its effect of plastic surgery on the life of the patients. Most of the film contained facial transplantation or the change of the face or body different from the original shape. Character type of the plastic surgeons was mostly medical realism, rather than ideal humanism. Most of the plastic surgeons have capability as a doctor; however, some of them had extramarital affairs. The surgery was successful in most of the cases, but were the patients happy with the results? This was not the case in the movies. In only one movie, '200 Pounds Beauty', the patient became happy; rest of them were eminently unhappy with the outcome. Why the discrepancy? It is difficult to analyze the minds of the people in the films, but considering that the majority of the characters in the films were rather unsavory, one may deduce that a crooked mind functions differently. Perhaps it is too much to hope for a day that will come when we will see a film that portrays the mental anguish that accompanies each and every procedure the Korean plastic surgeons make.

Preparation of Glass Thin Film onto Plastic Surface by Sol-Gel Process (Sol-Gel 공정으로 Plastic표면에 Glass박막 제조에 관한 연구)

  • 양천회
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.85-91
    • /
    • 1998
  • Sol-gel derived silica films were prepared by dip-coating onto polymethylmethacylate with Tetraethoxysilane(TEOS) as starting materials. Film properties such as viscosity and thickness were investigated as a function of dip speed, waterprecursor ratio, sol aging time. IR spectra of the gel films prepared from TEOS at various R are given. At small values of R the absorption peaks assignable to C-H vibration in $-OC_2H_5$ groups are observed around 3000 and 1500-1300 $cm^{-1}$. These bands indicate that the -$-OC_2H_5$ groups are retained in the gel at small values of R because of incomplete hydrolysis of TEOS. Film behaviour was interpreted in terms of the dependence of hydrolysis and condensation rates on the interplay between sol pH and waterprecursor ratio. Film thickness was found to increase by approximately a factor of two as waterprecursor ratio increased from two to six. Film thickness also increased with sol prepolymerization time. Surface quality was correlated with processing conditions.

  • PDF

The effects of Cu thin films sputter deposited at 5 and 100 mtorr on the adhesion between Cu/Cr film and polyimide (5, 100 mtorr의 증착압력에서 스퍼터 증착한 구리박막층이 Cu/Cr 박막과 폴리이미드 사이의 접착력에 미치는 영향)

  • 조철호;김영호
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.3
    • /
    • pp.157-162
    • /
    • 1996
  • The effects of microstructural change on the adhesion strength between Cu/Cr film and polyimide have been studied. Cr films (50 nm thick) and Cu films (500 or 1000 nm thick) were deposited on polyimide by DC magnetron sputtering. During Cu deposition the Ar pressure was 5 or 100 mtorr. The microstructure was observed by SEM and the adhesion was measured by T-peel test. Plastic deformation of peeled metal strips was characterized quantitatively by using XRD technique. The film in which Cu is deposited at 100 mtorr has higher adhesion strength than the film in which Cu is deposited at 5 mtorr. And in the film with same deposition pressure of 100 mtorr, the adhesion strength is increased as the deposited thickness increases from 500 to 1000 nm. The adhesion change of Cu/Cr can be interpreted as the difference in plastic deformation.

  • PDF

Gamma-ray Dosimetry with Thin Plastic Film

  • Yoo, Young-Soo;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.223-233
    • /
    • 1973
  • Thirty two different kinds of domestic plastic films for use in measuring high gamma-ray dose have been collected and their dosimetric characteristics investigated with the help of a Co-60 gamma radiation source. Among them a rigid polyvinyl chloride(PVC) film of 0.06mm in thickness which is manufactured by Lucky Chemical Co., Korea, seem to be the most suitable one for this purpose. The relation between optical density at 3100$\AA$ and radiation exposure in this PVC film was linear in the range of 0.6$\times$10$^{6}$ R to 1.3$\times$10$^{7}$ R, and also the film showed a good reproducibility within 9% under the standard experimental condition. The effect of absorbed dose, oxygen content of surrounding atmosphere and irradiation temperature have also been studied for this film. It appeared to have a good property in the dosimetrical point of view.

  • PDF

Polyurethane Semi-occlusive Dressing for Full Thickness Skin Graft Application (전층식피술에 적용한 폴리우레탄 반밀봉드레싱)

  • Lee, Hyuk Gu;Son, Dae Gu;Kim, Hyun Ji;Kim, Jun Hyung;Han, Ki Hwan
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.607-612
    • /
    • 2005
  • A traditional tie-over dressing may be applied to support the take of a skin graft. Although there are many advantage of this method, it has significant disadvantages, including time-consuming application. Furthermore, when the dressing is changed, the gauze becomes hard and can be stuck to the graft, causing damage and pain upon removal. The purpose of our study is to evaluate the effect of semi-occlusive dressing using polyurethane foam and film dressing($Allevyn^{(R)}$, $Opsite^{(R)}$) after full thickness skin graft. The authors treated 45 cases including burn scar contracture(n=38), syndactyly (n=1), absence of nipple-areolar complex(n=4), traumatic skin defect(n=1) and contact burn(n=1) with authors' method and 39 patients including burn scar contracture (n=39) with the tie-over dressing between 2000 and 2004. The patients in polyurethane foam and film dressing group ranged from 1 to 62 years of age (mean age, 15.1 years) and the patients in tie-over dressing group ranged from 2 to 60 years of age(mean age, 21.3 years). The postoperative results were analyzed according to the following measures: (1) the duration of graft-taking, (2) the admission period, (3) complications. Compared with the traditional tie-over dressing, polyurethane foam and film dressing was shown to be more successful in a reduced duration of graft-taking, in which was similar to the former in the rate of graft-taking, a reduced admission period and patient's discomfort. We concluded that semi-occlusive dressing using $Allevyn^{(R)}$ and $Opsite^{(R)}$ was an effective method after full thickness skin graft, which was easy to shape to difficult body locations, such as web spaces, fingers and maintains a moist environment for wound healing and does not stick to the wound.

Study about decreasing methods of printing ink solvents residue amounts on plastic food package materials (플라스틱 포장재의 잔존 인쇄 용제 감소 방안)

  • An, Duek-Jun;Cho, Hoon-Il
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • Amount of residual ink solvent on the packaging materials from Korea, Japan and Europe was measured and compared. The amount of packaging materials from Korea was much higher than that of Japan and Europe. To reduce the residual amounts of ink solvent, aging condition of printed packaging materials including aging time and temperature was modified and evaluated. Aging with high temperature and short time ($60^{\circ}C$ and 24 hours) was more effective for reduction of residual amount of ink solvent than that with low temperature and long time. To find out change of reduction pattern of residual amount of solvent according to plastic packaging material, several monolayer and multilayer packaging materials were selected. Among the monolayer packaging materials, the amount of EVOH and PET was lower than that of polyolefin plastic film including PE and PP. PP/EVOH/PET among the selected multilayer film showed the lowest amount of residual ink solvent on food packaging materials. Result of this research revealed that the residual amount of ink solvent can be reduced by proper selection of aging condition with and by appropriate application of mutilayer plastic film.

  • PDF

Development of Film Fixing System for Improving Overlap Defects in the Film Insert Injection Molding Process (필름 인서트 사출성형 공정의 오버랩 불량 개선을 위한 필름 고정 시스템 개발)

  • Kim, Jung-Ho;Mun, Ji-Hun;Park, Hong-Seok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.472-479
    • /
    • 2013
  • We carried out research into an environmentally friendly injection molding process that involves filling the mold with polymer after thin films are fixed into the cavity, without the coating, plating process. Film insert injection molding is a new technique in which molten plastic resin is injected into the cavity after films are precisely attached to the side of the mold wall. In the film insert injection molding process, the insert film is moved by the flow of the molten plastic resin. Overlap defects cause a decline in the productivity and the quality of the manufactured goods. To reduce overlap defects, new injection mold parts are proposed to produce automotive exterior parts using thin films. It is suggested that the best possible method would be to fix the thin films to one side of the mold wall, and develop interior pins to fix the films in the mold. Based on this new pin fixing system, the problem of the film being moved by the flow of the molten resin was improved.