• 제목/요약/키워드: Plasma test

검색결과 1,363건 처리시간 0.034초

Mutagenicity and Immune Toxicity of Emulsion-type Sausage Cured with Plasma-treated Water

  • Kim, Hyun-Joo;Sung, Nak-Yun;Yong, Hae In;Kim, Hanwool;Lim, Younggap;Ko, Kwang Hyun;Yun, Cheol-Heui;Jo, Cheorun
    • 한국축산식품학회지
    • /
    • 제36권4호
    • /
    • pp.494-498
    • /
    • 2016
  • Cold plasma has been developed to reduce microbial contamination and to improve safety of food and medical products. In addition, the technology can be used in the manufacture of sausages without addition of nitrite. To be applied in food industry commercially, the new technology should be safe and efficient. However, toxicological test of plasma-treated food is limited. Therefore, the purpose of this study was to determine the mutagenicity and immune toxicity of the meat products cured with plasma-treated water (PTW) as a nitrite source. Emulsion sausages were prepared with no nitrite (control), sodium nitrite (SCS), and PTW (SCP). For a mutagenicity test, the Ames test was performed with the sausage samples. For immune toxicity test, 8-wk-old female Balb/c mice were given free access to the sausages in order to evaluate the tumor necrosis factor (TNF)-α level. As a result, no mutagenicity was detected in the sausages by the Ames test. The serum TNF-α values were less than 10 pg/mL in mice after feeding control and treated samples for 32 d, indicating that no inflammatory response was occurred by feeding the sausages made by PTW. Therefore, the present study opens the possibility of using plasma-treated water as a nitrite source without any toxicity.

Action of atmospheric pressure non-thermal plasma on the biomolecules and bio-organism

  • Attri, Pankaj;Park, Ji Hoon;Kumar, Naresh;Ali, Anser;Kim, In Tae;Lee, Weontae;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.66.1-66.1
    • /
    • 2015
  • Plasma medicine is an upcoming research area that has attracted the scientists to explore more deeply the utility of plasma. So, apart from the treating biomaterials and tissues with plasma, we have studied the effect of plasma with different feeding gases on modification of biomolecules. Additionally, we have checked the action of nanosecond pulsed plasma on the biomolecules. We have checked the plasma action on proteins ((Hemoglobin (Hb) Myoglobin (Mb) and lysoenzyme), calf thymus DNA and amino acids. The structural changes or structural modification of proteins and DNA have been studied using circular dichroism (CD), dynamic light scattering (DLS), gel electrophoresis, protein oxidation test, UV-vis spectroscopy and 1D NMR, while Liquid Chromatograph/Capillary Electrophoresis-Mass Spectrometer(LC/CE-MS) based qualitative bio-analysis have been used to study the modification of amino acids. We have also shown the effect of NaCl and ionic liquid on the formation of OH radicals using electron spin resonance and fluorescence techinques.

  • PDF

Monte Carlo 법을 이용한 플라즈마 내의 이온 운동 해석 (alysis of ion motion in fusion plasma by Monte Carlo Simulation)

  • 이홍식;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.447-450
    • /
    • 1989
  • Single particle orbit in plasma is obtained by drift Hamiltonian formulation in magnetic coordinate. The collisional effect is implied by Monte Carlo Method and the velocity space diffusion, energy transfer to the back ground plasma and the variation of energy distribution of test particles are investigated from many particles analysis.

  • PDF

미세구조물을 이용한 혈구/혈장 분리 (Separation of Blood Cell and Blood Plasma Using Microstructure)

  • 김덕종;서지훈;손상욱;김재윤;윤의수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.743-747
    • /
    • 2004
  • In this study, micro blood separators capable of separating blood cell and blood plasma using microstructure are fabricated and their feasibility and separation performance are evaluated. Test results show the possibility of separating blood cell and blood plasma using microstructure. To improve separation performance and anti-clogging characteristic, technical points of tested micro blood separators are discussed and improved designs are presented.

  • PDF

Plasma-sprayed Coatings of Aluminium Oxide and Mulite

  • 소대화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.336-339
    • /
    • 2003
  • The present report is the investigation of the effects of the HIP treatment on plasma-sprayed ceramic coating of $Al_2O_3$, $Al_2O_3-SiO_2$ on the metal substrate. These effects were characterized by phase identification, Vickers hardness measurement, and tensile test before and after HIPing.

  • PDF

Adhesion of Plasma Spray Coated Hydroxyapatite Film on the Two-Step Anodized Dental Implant

  • Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.126-126
    • /
    • 2012
  • In this study, adhesion of plasma spray coated hydroxyapatite film on the two-step anodized dental implant was investigated. The plasma spray was carried out on the dental implant after two step anodization. The adhesion of coated HA film was investigated by FE-SEM after fatigue test. In the case of two-step anodized implant showed a good adhesion between implant and coated film.

  • PDF

Environmental test campaign of a 6U CubeSat Test Platform equipped with an ambipolar plasma thruster

  • Stesina, Fabrizio;Corpino, Sabrina;Borras, Eduard Bosch;Amo, Jose Gonzalez Del;Pavarin, Daniele;Bellomo, Nicolas;Trezzolani, Fabio
    • Advances in aircraft and spacecraft science
    • /
    • 제9권3호
    • /
    • pp.195-215
    • /
    • 2022
  • The increasing interest in CubeSat platforms ant their capability of enlarging the frontier of possible missions impose technology improvements. Miniaturized electrical propulsion (EP) systems enable new mission for multi-unit CubeSats (6U+). While electric propulsion systems have achieved important level of knowledge at equipment level, the investigation of the mutual impact between EP system and CubeSat technology at system level can provide a decisive improvement for both the technologies. The interaction between CubeSat and EP system should be assessed in terms of electromagnetic emissions (both radiated and conducted), thermal gradients, high electrical power management, surface chemical deposition, and quick and reliable data exchanges. This paper shows how a versatile CubeSat Test Platform (CTP), together with standardized procedures and specialized facilities enable the acquisition fundamental and unprecedented information. Measurements can be taken both by specific ground support equipment placed inside the vacuum facility and by dedicated sensors and subsystems installed on the CTP, providing a completely new set of data never obtained before. CTP is constituted of a 6U primary structure hosting the EP system, representative CubeSat avionics and batteries. For the first test campaign, CTP hosts the ambipolar plasma propulsion system, called Regulus and developed by T4I. After the integration and the functional test in laboratory environment, CTP + Regulus performed a Test campaign in relevant environment in the vacuum chamber at CISAS, University of Padua. This paper is focused on the test campaign description and the main results achieved at different power levels for different duration of the firings.

Radical Mist Generator Using a Water Plasma Jet and Its Sterilization Effect

  • Huh, Jin Young;Ma, Suk Hwal;Kim, Kangil;Choi, Eun Ha;Hong, Yong Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.175.1-175.1
    • /
    • 2016
  • In recent, tract infections such as atopic dermatitis, allergic rhinitis and a respiratory disease are increasing, giving rise to the atmospheric pollution, inflow of micro-size dust and side effect of humidifier disinfectant. In this context, the environment-friendly technology is required to eliminate airborne pathogens. We propose solution of the previous problems, making use of Radical Mist Generator (RMG). Existing technologies of air purification using a gas discharge produce harmful substances such as ozone, NOx, etc. However, the RMG uses a pure water as a plasma forming material. The RMG sprays the water mist, which contains reactive radicals to sterilize microorganisms. RMG is comprised of a power supply, plasma electrodes and a nozzle. In order to analyze the electrical characteristic and concentrations of reactive radicals, we employ an oscilloscope and a titration method. To test the sterilization effect of RMG, we used E.coli. We confirmed that E.coli was killed over 90%. Eventually, we expect that RMG can be promising tool for a purified system.

  • PDF

플라즈마를 이용한 분말형 금속 연료 알루미늄의 점화 특성 (Ignition Characteristics of Aluminum Metal Powder Fuel with Thermal Plasma)

  • 이상협;임지환;윤웅섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.737-744
    • /
    • 2011
  • 탄화수소 계열의 점화원과 달리 선행 연구된 스팀 플라즈마 점화기를 이용한 알루미늄 분말의 지속 연소 성공을 바탕으로, 고온의 플라즈마를 이용한 알루미늄 분말의 점화 특성을 알아보기 위해 산화제가 없는 환경을 조성하여 점화 특성 확인 실험을 수행하였다. 아르곤 플라즈마를 이용하여 이전의 연소 실험과 동일한 4500 K의 온도 조건 및 이송 가스를 이용한 입자 공급 조건을 조성하여 실험을 수행하였으며, 플라즈마의 온도는 방출분광법을 사용하여 측정하였고 점화 특성은 SEM 촬영과 EDS 분석을 통해 비교 분석하였다. 고온의 플라즈마 제트 내부를 통과한 알루미늄 분말은 탄화수소 계열의 점화원과 다르게 급격한 기화로 인한 점화 촉진 효과를 확인 할 수 있었다.

  • PDF

플라즈마를 결합한 바이오 트리클링 시스템에 의한 휘발성 유기물질의 제거 (Removal of Volatile Organic Compounds Using a Plasma Assisted Biotrickling System)

  • 김학준;한방우;김용진
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.727-733
    • /
    • 2007
  • In this study, a newly developed biotrickling system, combined with a non-thermal plasma reactor, was investigated to effectively treat gaseous contaminants such as VOCs (Volatile Organic Compounds). Three kinds of non-thermal plasmas (NTPs) such as a rod type dielectric barrier discharge (DBD) plasma, a packed bead type DBD plasma and a gliding arc (GA) plasma, were tested and compared in terms of power consumption. The rod type DBD plasma was selected as one for integration with biotrickling system due to its relatively high VOC removal efficiency, low power consumption and low pressure drop. Toluene and xylene as representatives of VOCs were used as test gases. The experiment results showed that the efficiency of biotrickling system was especially very low at the high gas concentration and high flow rate and the removal efficiencies of VOCs were considerably enhanced in the biotrickling system, when the DBD plasma was worked in front of that even at the high gas concentration and high flow rate.