• 제목/요약/키워드: Plasma measurements

검색결과 424건 처리시간 0.031초

Electrochemical Lithium Insertion/Extraction for Carbonaceous Thin Film Electrodes in Propylene Carbonate Solution

  • Fukutsuka, Tomokazu;Abe, Takeshi;Inaba, Minoru;Ogumi, Zempachi;Matsuo, Yoshiaki;Sugie, Yosohiro
    • Carbon letters
    • /
    • 제1권3_4호
    • /
    • pp.129-132
    • /
    • 2001
  • Carbonaceous thin films were prepared from acetylene and argon gases by plasma assisted chemical vapor deposition (Plasma CVD) at 873 K. The carbonaceous thin films were characterized by mainly Raman spectroscopy, and their electrochemical properties were studied by cyclic voltammetry and charge-discharge measurements in propylene carbonate (PC) solution. Raman spectra showed that crystallinity of carbonaceous thin films is correlated by the applied RF power. The difference of the applied RF power also affected on the results of cyclic voltammetry and charge-discharge measurements. In PC solution, intercalation and de-intercalation of lithium ion can occur as well as in the mixed solution of EC and DEC.

  • PDF

Direct Aerosol Analysis by Time Resolved Laser Plasma Spectroscopy - Improvement by Single Shot Measurements

  • Schechter, Israel
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.779-786
    • /
    • 1995
  • Environmental and industrial aerosols can be analyzed on-line by laser plasma spectroscopy. The main problem in direct (no preparation or presorting) aerosol analysis is the extensive spectral fluctuations. A method to partially solve this problem is proposed. It is based on single shot measurements and application of a special rejection algorithm. The major factors that influence the spectral variations are discussed, in relation to the correction possibility by a rejection program. The method works well when average intensity of the single spectra is relatively high, as compared to detector's saturation limit. If intensities are too low, the accumulation of readout noise is critical, and no improvement is expected.

  • PDF

Millimeter-wave Fast-sweep FM Reflectometry Applied to Plasma Density Profile Measurements

  • Kang, Wook-Kim
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.18-23
    • /
    • 2001
  • A fast-sweep broadband FM reflectometer system has been successfully developed and operacted at the DIII-D tokamak, producing reliable density Profiles with excellent spatial (1 $\leq$ cm) and temporal resolution (~100 $\mu$ s). The system uses a solid-state microwave oscillator and an active quadrupler, covering full Q-band frequencies (33~50 GHz) and providing relatively high output power (20~60 mW). The system hardware allows fu11band frequency sweep in 10 $\mu$ s, but due to digitization rate limit on DIII-D, sweep time was limited to 75~100 $\mu$ s. Fast frequency sweep has helped to reduce density fluctuation effects on the reflectometer phase measurements, thus improving reliability for individual sweeps. The fast-sweep system with high spatial and temporal resolution has allowed to measure fast-changing edge density profiles during plasma ELMS and L-H transitions, thus enabling fast-time sca1e physics studies.

  • PDF

Organic Thin Film Transistors with Gate Dielectrics of Plasma Polymerized Styrene and Vinyl Acetate Thin Films

  • Lim, Jae-Sung;Shin, Paik-Kyun;Lee, Boong-Joo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권2호
    • /
    • pp.95-98
    • /
    • 2015
  • Organic polymer dielectric thin films of styrene and vinyl acetate were prepared by the plasma polymerization deposition technique and applied for the fabrication of an organic thin film transistor device. The structural properties of the plasma polymerized thin films were characterized by Fourier-transform infrared spectroscopy, X-ray diffraction, atomic force microscopy, and contact angle measurement. Investigation of the electrical properties of the plasma polymerized thin films was carried out by capacitance-voltage and current-voltage measurements. The organic thin film transistor device with gate dielectric of the plasma polymerized thin film revealed a low operation voltage of −10V and a low threshold voltage of −3V. It was confirmed that plasma polymerized thin films of styrene and vinyl acetate could be applied to functional organic thin film transistor devices as the gate dielectric.

서브마이크로 펄스 전압파형을 이용한 대기압 저온 마이크로 플라즈마 소스 개발 (The Development of Non-thermal Micro Plasma Source Under Atmospheric Pressure by Means of Submicrosecond Pulse Voltage Waveforms)

  • 최준영;이호준;김동현;이해준;박정후
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1802-1806
    • /
    • 2007
  • Nowadays, many configurations and applications of small atmospheric plasma source have been investigated with growing interest, as it provides the bacteria inactivation, the surface modification and removal of unwanted small regions, and so on. In this paper, the non-thermal micro plasma source under atmospheric pressure by means of submicrosecond pulse voltage waveforms is suggested. Plasma operates in helium is appears as a small (sub-mm) glow at the tip of a plasma gun. Electrical measurements show that the plasma source operates at low voltage (about 500V) and the power consumption is about 1W at 25kHz. Moreover, the emission spectrum shows the relatively higher emission intensity of oxygen particles than those of helium and nitrogen.

Micro-PIV를 이용한 마이크로 튜브/채널 내에서의 혈장유동 측정 (Measurements of Plasma Flows in Micro-Tube/Channel Using Micro-PIV)

  • 고춘식;윤상열;지호성;김재민;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.87-90
    • /
    • 2003
  • In this paper, flow characteristics of plasma flow in a micro-tube were investigated experimentally using Micro-PIV. For comparision, the experiments were repeated for DI-water instead of plasma. Both velocity profiles of Plasma and DI-water are well agreed with the theoretical velocity distribution of newtonian fluid. We also carried out generating plasma-in-oil droplet formation at a Y-junction microchannel. In order to clarify the hydrodynamic aspects involved in plasma droplet formation. Rhodamin B were mixed with plasma only for visualization of plasma droplet.

  • PDF

An Indirect Method to Monitor Plasma Status in a Transformer Coupled Plasma

  • 유대호;안승규;김지훈;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.216-216
    • /
    • 2011
  • There have been various direct or indirect methods to measure the characteristics of plasma. Comparing to direct method like Langmuir probe method, indirect measurements which give information as some external parameters like current, voltage, or phase are easier to obtain. In this research, an indirect method to measure averaged plasma density in a transformer coupled plasma(TCP) has been proposed and evaluated. With a simple analytic model connecting electrical characteristics to plasma impedance, direct measurement via double Langmuir probe has been performed. This result may play a meaningful role to diagnose TCP or similar plasma sources

  • PDF

성인의 영양소 섭취상태 및 체위와 혈액내 지방수준과의 상관관계에 관한 연구 (The effect of dietary intake and anthropometric parameters on the plasma lipid level)

  • 이경애
    • 대한가정학회지
    • /
    • 제33권6호
    • /
    • pp.89-97
    • /
    • 1995
  • This study was undertaken to examine the correlations between dietary intakes or anthropometric parameters and the plasma lipid level. measurements of dali nutrients intake, body weight, height, body bass index, skinfold thickness, blood pressure, plasma total lipid, triglyceride and cholesterol were made to each of 124 healthy adult(25-59yrs) : 56 males and 65 females. The mean energy and nutrients intake, anthropometric parameters and plasma lipid levels were all in normal range. In females, the fat and protein intake, the amount and percents to total energy intake, had positive association with the plasma total lipid, but the energy percent from carbohydrate intake was correlated negatively. And body mass index positively correlated with plasma total lipid level, in male and female, Therefore we could postulated the dietary fat intake and body mass index affected to plasma lipid levels in normal conditions of healthy adult.

  • PDF

Low Latitude Plasma Blobs: A Review

  • Kim, Vitaly P.;Hegai, Valery V.
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권1호
    • /
    • pp.13-19
    • /
    • 2016
  • In recent years, there has been renewed activity in the study of local plasma density enhancements in the low latitude F region ionosphere (low latitude plasma blobs). Satellite, all-sky airglow imager, and radar measurements have identified the characteristics of these blobs, and their coupling to Equatorial Plasma Bubbles (EPBs). New information related to blobs has also been obtained from the Communication/Navigation Outage Forecasting System (C/NOFS) satellite. In this paper, we briefly review experimental, theoretical and modeling studies related to low latitude plasma blobs.

체외순환에 따른 혈장 단백 함량과 폐포모세혈관 산소 분압차의 변화 (Changes in Plasma Protein Concentration and Alveolar -Arterial Oxygen Tension Differnce Associated with CPB-)

  • 전태국
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1084-1089
    • /
    • 1990
  • Plasma protein concentration, plasma albumin concentration, hematocrit, and arterial blood gas tension were measured in 15 mongrel dogs undergoing heart transplantation with cardiopulmonary bypass. The hemodilution due to priming solution resulted in a 49% decrease in plasma protein concentration, a 57% decrease in plasma albumin concentration, a 46%a decrease in hematocrit. The measurements had returned to preperfusion values 1 hour after the end of cardiopulmonary bypass. The intraoperative changes in plasma protein and albumin concentration did not correlate with changes in alveolar-arterial oxygen tension gradients[D[A\ulcorner PO2]]. It is concluded that, in the absence of an increase in left atrial pressure, marked decrease in plasma protein concentration can be tolerated without the occurrence of pulmonary edema. And further study should be done to determine how to prepare an ideal priming solution.

  • PDF