• 제목/요약/키워드: Plasma discharge device

검색결과 94건 처리시간 0.026초

히터 일체형 하이브리드 단판형 플라즈마 방전소자 (One-Plate Type Hybrid Plasma Discharge Device with Heating Element)

  • 최우진;최은혜;성형석;권진구;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

DBD (Dielectric Barrier Discharge) Plasma Device for Biomedical Applications

  • 김윤중;김중길;정종윤;한국희;이민경;차덕봉;한상호;박경순;조광섭
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.461-461
    • /
    • 2012
  • 미생물 처리에 적용하기 위한 저주파 Dielectric Barrier Discharge (DBD) Plasma Device를 고안하였다. 현재 생의학적으로 광범위하게 사용되는 Plasma Jet Device는 가스를 주입해 주어야 한다. 그러나 Plasma Jet Device의 노즐로부터 배출되는 가스는 Media의 흔들림과 증발 유발시키며 미생물에게 영향을 미친다. 가스 배출에 의한 영향을 없애기 위해 가스 주입이 없는 Plasma 발생 장치를 제작 하고, 미생물에 적용하여 그 효과를 관찰하였다. 본 실험에 사용된 Plasma 발생 장치는 대기 중에서 방전된다. 가스의 주입 없이 낮은 방전 전압과 균일한 플라즈마의 발생을 위해 Plasma 발생 장치의 접지 전극으로 Mesh를 사용 하였다. 본 Plasma 발생 장치로 발생된 Plasma를 곰팡이(Fusariumgraminearum)에 조사한 결과, 조사 시간이 길어짐에 따라 배양된 곰팡이의 Colony 수가 Plasma를 조사하지 않은 경우에 비해 줄어드는 것을 확인할 수 있었다. 또한 각각의 곰팡이 Colony의 크기도 줄어들었다.

  • PDF

Flexible Plasma Sheets

  • Cho, Guangsup;Kim, Yunjung
    • Applied Science and Convergence Technology
    • /
    • 제27권2호
    • /
    • pp.23-25
    • /
    • 2018
  • With respect to the electrode structure and the discharge characteristics, the atmospheric pressure plasma sheet of a thin polyimide film is introduced in this study; here, the flexible plasma device of a dielectric-barrier discharge with the ground electrode and the high-voltage electrode formulated on each surface of a polyimide film whose thickness is approximately $100{\mu}m$, that is operated with a sinusoidal voltage at a frequency of 25 kHz and a low voltage from 1 kV to 2 kV is used. The streamer discharge is appeared along the cross-sectional boundary line between two electrodes at the ignition stage, and the plasma is diffused on the dielectric-layer surface over the high-voltage electrode. In the development of a plasma sheet with thin dielectric films, the avoidance of the insulation breakdown and the reduction of the leakage current have a direct influence on the low-voltage operation.

개선된 플라즈마 공정을 이용한 Ralstonia Solanacearum 불활성화에 관한 연구 (A Study on the Ralstonia Solanacearum Inactivation using Improved Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.369-378
    • /
    • 2014
  • Effect of improvement of the dielectric barrier discharge (DBD) plasma system on the inactivation performance of bacteria were investigated. The improvement of plasma reactor was performed by combination with the basic plasma reactor and UV process or combination with the basic plasma reactor and circulation system which was equipped with gas-liquid mixer. Experimental results showed that tailing effect was appeared after the exponential decrease in basic plasma reactor. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of basic plasma process and UV process. The application of gas-liquid mixing device on the basic plasma reactor reduced inactivation time and led to complete sterilization. The effect existence of gas-liquid mixing device, voltage, air flow rate (1 ~ 5 L/min), water circulation rate (2.8 ~ 9.4 L/min) in gas-liquid mixing plasma, plasma voltage and UV power of gas-liquid mixing plasma+UV process were evaluated. The optimum air flow rate, water circulation rate, voltage of gas-liquid mixing system were 3 L/min, 3.5 L/min and 60 V, respectively. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of gas-liquid mixing plasma and UV process.

분위기 온도와 플라즈마 방전에 의한 AC-PDP의 형광막 열화 특성 (The Degradation Characteristics of Phosphor Layers by Environmental Temperature and Plasma Discharge in AC-PDPs)

  • 김현;장상훈;태흥식;최경철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.443-448
    • /
    • 2002
  • The degradation characteristics of R, G, B phosphor layers in AC-PDP, which is due to the discharge of plasma, are still unknown. For the successful commercialization of AC-PDP, the degradation of phosphor layers, caused by the plasma discharge must be investigated and improved. In this paper, the degradation properties of phosphor layers in AC-$PDP_S$ are investigated. It takes long time to investigate the degradation in real condition, so that the device for accelerating the degradation is devised. To prove the performance of the device, the visible emission characteristics of phosphor layers and discharge with the environmental temperature are examined. As a result, it is shown that the phosphor layers are easily degraded when the discharge is sustained under high environmental temperature condition. After accelerating the degradation of blue Phosphor layer((Ba,Eu)Mg$AI_10$$O_17$) for 48 hours, its luminance decreases about 38 % and the corresponding color purity deteriorates severely.

바이오-메디컬 응용을 위한 마이크로 플라즈마 분사 소자 (Microplasma-Jet Device for Bio-medical Application)

  • 김강일;홍용철;김근영;양상식
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2474-2479
    • /
    • 2009
  • This paper presents an atmospheric microplasma-jet device for bio~medical application. The microplasma-jet device consists of four components; a thin Ni anode, porous alumina insulator, a stainless steel cathode and an aluminum case. The anode has 8 holes, and hole diameter and depth are $200 {\mu}m$ and $60 {\mu}m$, respectively. The discharge test was performed in atmospheric pressure using nitrogen gas and AC voltage at the optimum gas flow rate of 4 Vmin. The plasma-jet is ejected stably for the input voltage ranging from 5.5 to $9.5 kV_{p-p}$. The plasma becomes dense as the input voltage increases, which was verified by the hydrophilicity change of PMMA surface treated by the plasma. The temperature increasement of the aluminum film exposed to plasma-jet illustrates that the micro plasma-jet device is feasible for bio-medical application.

Plasma Propagation Speed and Electron Temperature of Atmospheric Pressure Non-Thermal Ar Plasma Jet

  • 한국희;김동준;김현철;김윤중;김중길;이원영;나야나;조광섭
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.512-513
    • /
    • 2013
  • Space and time resolved discharge images from an atmospheric pressure non-thermal Ar plasma jet have been observed by a ICCD camera to investigate the electron temperatures. Plasma jet device consisting of a syringe electrode inserted into a glass tube has been introduced. A high voltage is applied to the syringe electrode. The syringe needle has an outer diameter of 1.8 mm, an inner diameter of 1.3 mm, and a total length of 39.0 mm. The needle is inserted into a glass tube of outer diameter 2.4 mm and inner diameter 2.0 mm, and a total length of 80.0 mm. The Ar plasma propagation speed on the cathode has been shown to be about 2.1 km/s at input discharge voltage of 3.6 kV, discharge current of 19.9 mA and driving frequency of about 45 kHz. Particularly, the electron temperature in plasma jet were found to be about 1.8 eV at input discharge voltage of 3.6 kV and driving frequency of 45 kHz, respectively.

  • PDF

The effect of the cell size on the discharge characteristics of a plasma display panel

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • 제12권1호
    • /
    • pp.29-35
    • /
    • 2011
  • In this study, plasma display panels with three different cell volumes were prepared by changing the spaces between the vertical barrier ribs into two and three times the reference structure. The discharge gap and area of the segmented ITO electrode were the same for the three cases, and Ne.20%Xe gas was used. The luminance and luminance efficiency were measured using applied voltage variations. The time evolution and intensity distribution of the infrared, which are related to the vacuum ultraviolet, were observed via intensified, charged, coupled device, and the visible-light intensity profiles were observed using PR-900 to analyze the discharge phenomena in the discharge cell.

3-Dimensional Emission characteristics of an AC PDP Cell

  • Jung, Jae-Chul;Jeong, Dong-Cheol;Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.529-532
    • /
    • 2004
  • The spatio-temporal variation of Infra Red(IR) emission images were obtained from a real 3-dimensional discharge space of a surface discharge type, alternating current plasma display panel(AC PDP) cell with the Ne-Xe(4%) 400Torr gas mixture. IR emissions were observed in each period of the ADS(Address and Display Separation) driving scheme with ramp initializing waveform using an images intensified charge coupled device(ICCD) camera. The roles of each electrode were identified and it was compared with the results of the discharge simulation and of the wall charge distributions measured by the electro-optic technique.

  • PDF

KSTAR 토카막 장치 진공 기술 현황 (Status of vacuum technique in KSTAR)

  • 김광표;김현석
    • 진공이야기
    • /
    • 제4권1호
    • /
    • pp.16-23
    • /
    • 2017
  • Recently, KSTAR, Korea's superconducting fusion energy research and development device, has succeeded in driving the high performance plasma for 70 seconds for the first time in the world. Continuous plasma operation technology is an essential factor for commercialization of fusion energy power generation. Therefore, this achievement is expected to play a major role in the research of fusion technology required for future fusion power plants. In order to operate the KSTAR, the discharge process in which the neutral gas is turned into the plasma should be preceded in the start-up (breakdown) phase of tokamak operation. This process essentially involves the vacuum environment in the tokamak device. KSTAR has successfully operated a vacuum pumping system to achieve the target level of the vacuum environment through a high temperature baking operation, a discharge cleaning process and boronization.