• Title/Summary/Keyword: Plant Maintenance

Search Result 930, Processing Time 0.025 seconds

Generator Protection Relaying System in Power Plant (발전소의 발전기 보호계전시스템)

  • Kwan, Sung-Kyun;Park, Chul-Won;Lee, Jong-Soo;Lee, Sang-Seung;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.151-152
    • /
    • 2006
  • Because power plant faults have severe effects on the power system and on mechanical maintenance of the generator, reliable protection systems are needed. In this paper, we compared and analyzed methods of the generator protection relaying system, which can defect internal faults of the generator, and surveyed the trends in generator protection using digital computing.

  • PDF

Development of Power Supply Testing System (전원공급기 점검장치 개발)

  • Park, Jong-Beom;Kim, Young-Hwa;Lee, Hae-Kyou;Lee, Nak-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.703-705
    • /
    • 1999
  • The Power supplies used commonly in the Nuclear, Thermal and Hydraulic Power Plant are required to test the function and reliabilities. For the better contribution of reliable operation and speedy maintenance of Power Plant, it is necessary to gather and analyze the datum, to print out the result of testing using PC and proper controllers. Various kinds of power supply shall be tested and examined automatically. By storing the test results in the Database it is possible to find out the changing of characteristics of power supplies. So it is very useful to prevent any problems that may occur in the power supplies.

  • PDF

IMPROVED POD METHODOLOGY USING MONTE CARLO SIMULATION

  • Park, Ik-Keun;Yoon, Jong-Hak;Ro, Sing-Nam;Seo, Seong-Won;Namkoong, Chai-Kwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.73-78
    • /
    • 2003
  • Ultrasonic measurement is one of important technologies in the lift-time maintenance of nuclear poler plant. Ultrasonic inspection system is consisted of the operator, equipment and procedure. The reliability of ultrasonic inspection system is affected by its ability. The performance demonstration round robin was conducted to quantify the capability of ultrasonic inspection for in-service. The small number of teams who employed procedures that met or exceeded ASME Sec. XI Code requirements detected the piping of nuclear power plant with various cracks to evaluate the capability of detection and sizing. In this paper, the statistical reliability assessment of ultrasonic nondestructive inspection data using Monte Carlo simulation is presented. The results of the probability of detection (POD) analysis using Monte Carlo simulation are compared to these of logistic probability model. In these results, Monte Carlo simulation was found to be very useful to the reliability assessment f3r the small hit/miss data sets.

  • PDF

사용후핵연료 저장 시설의 중대사고 안전성 검토

  • Sin, Tae-Myeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.331-336
    • /
    • 2011
  • When the Fukushima nuclear power plant accident occurred in March, a hydrogen explosion in the reactor building at the 4th unit of Fukushima plants lead to a big surprise because the full core of the unit 4 reactor had been moved and stored underwater at the spent nuclear fuel storage pool for periodic maintenance. It was because the potential criticality in the fuel storage pool by coolant loss may yield more severe situation than the similar accident happened inside the reactor vessel. In the paper, the safety state of the spent fuel storage pool and rack structures of the domestic nuclear plants would be reviewed and compared with the Fukushima plant case by engineering viewpoint of potential severe accidents.

  • PDF

Storage of Phytopathogenic Fungal Cultures in Sterile Distilled Water (식물병원 진균 균주의 살균증류수 저장법)

  • 이종규;최경자;김병섭;조광연
    • Korean Journal Plant Pathology
    • /
    • v.10 no.2
    • /
    • pp.144-147
    • /
    • 1994
  • About 450 phytopathogenic fungal cultures were stored in sterile distilled water ar room temperature by the sterile water storage method, which has been known as a simple, convenient, and long-term storage method of microorganisms. After 12 months, viability and pathogenicity of the stored isolates were tested. Among 205 tested, 175 isolates (84.5%) survived. Of these, Rhizoctonia solani, Botrytis cinerea, Pyricularia oryzae, Phytophthora infestans, and Sclerotinia sclerotiorum showed relatively lower survival rate; 92%, 74.1%, 62.5%, 45.8%, and 30%, respectively. Twenty seven isolates belonging to seven important phytopathogenic fungi were tested for pathogenicity, and all isolates tested maintained pathogenicity until at least 12 months after storage.

  • PDF

Identification of control system of No.1 Plate Mill in POSCO (포항제철(浦項製鐵) 1후판(厚板) 압연(壓延) ROLL 구동계(驅動係)의 식별(識別)에 관(關)한 연구(硏究))

  • Jeong, Ho-Seong;Kang, Myung-Jo
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.147-149
    • /
    • 1987
  • On the colling mill plant, the qulity of products depends on the ability to follow up the command of roll speed and the magnitude of impact drop. In this paper, the frequency response method is applied to the main motor system of No.1 Plate Mill Plant in POSCO. This paper show the influences when the pseudo random noise as test signal is applied to the system to be measured and presents the proper magnitude of test signal.

  • PDF

INSTORE : A PC-Based Database Program for Occupational Radiation Exposure of a Nuclear Power Plant

  • Cho, Yeong-Ho;Kang, Chang-Sun;Mun, Ju-Hyung;Kim, Hak-Su
    • Nuclear Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.308-317
    • /
    • 1998
  • Ensuring occupational radiation exposure(ORE) as low as is reasonably achievable(ALARA) has been one of very important requirements in a nuclear power plant. It is well known that about 70 percent of occupational dose has incurred from maintenance jobs in the outage period. To reduce occupational dose effectively, the high-dose jobs in the outage period should be identified with their dose reduction potentials and methods. In this study, a PC-based ORE database program, INSTORE, is developed to evaluate ORE doses in individual jobs, and the ORE data of Kori Units 3 and 4 are assembled to the database. Based on customary job classification, radiation work is classified into 26 main jobs which comprise 61 detailed jobs, and occupational doses are assessed according to each detailed job. As a result, high-dose jobs are identified with dose reduction priority in terms of collective ORE dose. It is recommended that adeqaute dose reduction methods for these jobs should be prepared to improve their working conditions and procedures.

  • PDF

Analysis of Local Wall Thinning around the Extraction Steam Entrance for the 6th Feedwater Heater Shell in the Nuclear Power Plants (원전 6단 급수가열기 추기증기 입구노즐 주변의 동체 국부 감육 원인 분석)

  • Song, Seok-Yoon;Kim, Hyung-Nam
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.4
    • /
    • pp.54-62
    • /
    • 2009
  • The feedwater heaters are Critical components in a nuclear power plant. As the operation years of heaters go by, the maintenance costs required for continuous operation increase. When the carbon steel components in nuclear make contact with running fluid, the wall thinning caused by FAC (flow accelerated corrosion) can be generated. Local wall thinning is inevitable at the area around wet steam entrance to be attacked due to the long term operation. Sometimes the shell with thinned wall is eventually ruptured. To identify the relationship between the local wall thinning and fluid behavior of the feedwater heater, the practical data of a plant, which were based on ultrasonic thickness measurement tests, were analyzed and CFD(Computed Fluid Dynamics) analyses were performed.

Stability Analysis of Compressed Air Storage Caverns in Rockmass (전력생산을 위한 암반내 압축공기저장공동의 안정성분석)

  • 신희순;신중호;최성웅;한일영;김정엽
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.287-294
    • /
    • 2002
  • CAES which is called as a compressed air energy storage was firstly developed at Huntorf, German in 1978. The capacity of that system was 290MW, and it can be treated as a first commercial power plant. CAES has a lot of merits, such as saving the unit price of power generation, averaging the peak demand, improvement of maintenance, enlarging the benefit of dynamic use. According to the literature survey, the unlined rock cavern should be proposed to be a reasonable storing style as a method of compressed air storage in Korea. We decided the hill of the Korea Institute of Geoscience and Mineral Resources as CAES site. If we construct the underground spaces in this site, the demand for electricity nearby Taejon should be considered. So we could determine the capacity of the power plant as a 350MW, This capacity needs a underground space of 200,000㎥, and we can conclude 4 parallel tunnels 550m deep from the surface through the numerical studies, Design parameters were achieved from 300m depth boring job and image processing job.

  • PDF

Design of the Wire Rope Type Snubber for Earthquake and Vibration of Piping System (Wire Rope형 배관 지진$\cdot$진동완충기의 설계)

  • 김영중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.173-179
    • /
    • 1998
  • The piping system of a power plant suffers not only thermal expansion according to the temperature variation, but also many kinds of load: steady state vibrations due to the equipment operation or fluid flow, and transient vibrations due to the earthquake or explosion, etc. The snubbers are usually installed on the piping system to allow thermal expansion, and to reduce dynamic responses. Most snubbers are kinds of hydraulic and mechanical type, which can be degraded by leakage and abrasion, and required much cost for maintenance and replacement. Recently the wire rope type snubbers are developed and applied to the power plant, and proved as effective to reduce piping system vibration. Wire rope type snubber uses the bending rigidity and energy dissipation properties of ropes. This paper presents the procedure of design, and the method to apply hysteresis curve to the dynamic response analysis. Experiments were also conducted to confirm design results.

  • PDF