• Title/Summary/Keyword: Planar Coil

Search Result 72, Processing Time 0.036 seconds

Experiments of a Novel Magnetic Levitation Stage for Wide Area Movements

  • Jeon, Jeong-Woo;Caraiani, Mitica;Oh, Hyeon-Seok;Kim, Sung-Shin
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.558-563
    • /
    • 2012
  • In this paper, a novel planar type magnetic levitation system without other assistant devices is proposed and it can move with 6 degree of freedom (X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$) in wafer size as well as in nano scale positioning.The mover is composed with 2-D Halbach permanent magnet array and the stator is composed with $10{\times}10$ coil arrays.It was composed in laboratory and tested with short stroke (4 [mm]) and long stroke (160 [mm])movements. The errors of short movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}3urad$, ${\pm}2urad$, ${\pm}1urad$]The errors of long stroke movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}1.5urad$, ${\pm}2urad$, ${\pm}0.5urad$].

Study the Properties of Silicon Nitride Films prepared by High Density Plasma Chemical Vapor Deposition

  • Gangopadhyay, Utpal;Kim, Do-Young;Parm, Igor Oskarovich.;Chakrabarty, Kaustuv;Kim, Chi-Hyung;Shim, Myung-Suk;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1127-1130
    • /
    • 2003
  • The characteristics of silicon nitride films deposited in a planar coil reactor using a simple high-density inductively coupled plasma chemical vapor deposition technique have been investigated. The process gases used during silicon nitride deposition cycle were pure nitrogen and a mixture of silane and helium. It has been pointed out that the strong H-atom released from the growing SiN film and Si-N bond healing are responsible for the improved electrical and passivation properties of SiN.

  • PDF

A Study on Low Power Energy Transfer Circuits of the Non Contact Method by means of Solar Generation (태양광 발전에 의한 비접촉 방식 저 전력 에너지 전송회로에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Kim, Jong-Rae;Choi, Gi-Ho;Kim, Jin-Seon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.1
    • /
    • pp.35-43
    • /
    • 2014
  • In this paper, it is about to non-contact wireless power transmission according to various conditions of self induction principle between the two planar coils at a transmission unit and a receiving unit based on the theory of wireless power transmission. The experiments are occurred in order to power transfer of noncontact method from designed wireless circuits in the primely coil and secondary coil, and the applying to Half Bridge Resonant converter transmission unit and receiving unit. and that were able to prepared circumstance to calculate of the output voltage and power source. The main power of the inductive coupling the resonant converter at the transmission unit is converted electrical energy using the solar cell module and artificial light source (halogen lamp) as a replace light and received 24 V power supply from solar power was used a input power source for the wireless power transmission device. Experimental results, to received of power is used to illuminate the lighting and to charge the battery in receiving circuit.And the wireless power transmission efficiency measured at the output side of the transmission unit is obtained about 70% to 89% compared to input power of receiving unit.In addition, efficiency were tested through ID verification method and comparing the phase difference between the voltage when foreign substances interfere with wireless power transmission.

The method of alignment detection between Tx and Rx set in wireless inductive charger (유도방식 무선충전기용 송수신 장치간 정렬상태 검출기법)

  • Lee, Sang Gon;Kim, Jae Moung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.90-96
    • /
    • 2014
  • This paper is about increasing transfer efficiency of wireless power transmission. The new method is proposed to detect the alignment of transmitter and receiver of wireless charger and so smart phone can display the position of wireless charging receiver on its LCD panel for the maximum charging efficiency. The previous method is only to show the transfer efficiency, but this method is to show not only the efficiency but also coordinates of receiver. The apparatus of the wireless charger is based on WPC(Wireless Power Consortium) standard and has planar air coil combined with magnet shield in Tx and Rx device so that the leakage flux is minimized on condition of under hundreds of kHz operating frequency. In this paper, it's showed that relation of magnet field and distance of each coils can be linearized and position information of Tx and Rx device is calculated thru trigonometry. Through the experiment, the obstacles of linearity are discovered and also showed that it can be optimized. and so the presented method is suitable for alignment detection method of Tx and Rx device in WPC wireless charger.

Trial Maunfacture of Planar Type Micro Inductors (평면형 마이크로인덕터의 시작에 관한 연구)

  • 김종오;강희우;김영학;김동연;오호영
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.6
    • /
    • pp.367-374
    • /
    • 1996
  • The developmement of electronic machine industries requires miniature of size as well as increasement of driving frequency in electronic parts, recently. To realize micro-struture of magnetic devices, in this study, we fabricated thin film inductors by using thin film manufacturing techniques such as photolithography and wet etching process, and these devices are measured at high frequency range of 1 MHz~1 GHz. The results are as follows. The accurate measuring technique by using network analyzer system having microstrip line was established. The manufactured inductors are fabricated with several ten micrometers by means of wet etching process known as easier and more economic than dry etching process. VVhen the device size of two types (spiral, meander) is the same, inductance value L and quality factor Q of spiral type devices are larger than those of meander type, but driving frequency of spiral type is lower than that of meander type due to increasement of inductance L. It is necessary to decrease resistance value R by increasing cross section of the conductor film coil. Thus high frequency measuring method would be a very useful for another measuring fields of the range over several hundreds MHz.

  • PDF

Design and Trend Analysis According to the Application Field of Monopole Antenna with Sleeve Structure (슬리브 구조를 갖는 모노폴 안테나의 활용분야에 따른 설계와 동향분석)

  • Kang, Sang-Won;Byeon, Mi-Kyeong;Lee, Shin-Hee;Choe, Gwang-Je
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.135-141
    • /
    • 2020
  • This paper summarizes the data of a monopole antenna with a sleeve structure that can be applied in various ways. Sleeve monopole antennas have broadband characteristics and are used for multi-frequency applications. The sleeve monopole antenna is composed of a vertical conductor, which is a radiator, and a sleeve having the same structure as a coaxial cable. The sleeve acts as a radiator and an open stub. The length of the sleeve should be 1/3~2/3 of the total length of the antenna. A monopole antenna having a sleeve structure is applicable to a vehicle wiper antenna. In addition, the case of applying this antenna to a broadband sleeve antenna using a loading coil, a broadband printed sleeve monopole antenna for an ISM band, a gap sleeve and a double sleeve, and a UWB planar monopole antenna using half cutting was summarized and analyzed in terms of structure and broadband.

Durability and Characteristics of Ag-Pd Rod Heater for Bidet Fabricated by Screen Printing Process (스크린 프린팅 공정에 의해 제조된 비데용 Ag-Pd 봉형 발열체의 내구성 및 물성 평가 )

  • Tae-Ung Park;Da-Eun Hyun;Ik-Soo Kim;Sung-Chul Lee;Yeon-Sook Lee;Yong-Nam Kim;Dong-Won Lee;Jong-Min Oh
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.81-87
    • /
    • 2023
  • Heaters using the resistance heating principle are used in various industrial fields that require heat and are also essentially used in bidet among small home appliances. A planar heater and a coil-inserted heater mounted on a conventional commercially used bidet have disadvantages and limitations of complicated manufacturing process and local heating. In this study, silver-palladium (Ag-Pd) powder material was used for a screen-printing process that is more advantageous in achieving simplification than the existing process, and a rod-type heater for bidet was manufactured. The on-off cycle test under actual conditions was conducted to confirm the durability and the capability of the fabricated heater, and the fabricated heater operated more than 2,600 on-off cycles, which means it could be applied for a commercial product. In addition, through the on-off cycles under harsh conditions, the cause of failure was identified after the test that the durability limit temperature of the heater was 850℃. Through Ag-Pd rod heater in this study, it is expected to contribute to the efficient development of electrode materials for heaters and the improvement of the durability of heaters in the future.

Identification of Void Diameters for Cast-Resin Transformers (몰드변압기의 보이드 결함 크기 판별)

  • Jeong, Gi-woo;Kim, Wook-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.570-573
    • /
    • 2022
  • This paper presents the identification of void diameters for a cast-resin transformer using an artificial neural network (ANN) model. A PD signal was measured by the Rogowski coil sensor which has the planar and thin structures fabricated on a printed circuit board (PCB), and the PD electrode system was fabricated to simulate a PD defect by a void. In addition, void samples with different diameters were fabricated by injecting air in a cylindrical aluminum frame using a syringe during the epoxy curing process. To identify the diameter of void defects, PD characteristics such as the discharge magnitude, pulse count, and phase angle were extracted and back propagation algorithm (BPA) was designed using virtual instrument (VI) based on the Labview program. From the experimental results, the BPA algorithm proposed in this paper has over 90% accurate rate to identify the diameter of void defects and is expected to use reference data of maintenance and replacement of insulation for cast-resin transformers in the on-site PD measurement.

  • PDF

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.