• 제목/요약/키워드: Planar Coil

검색결과 72건 처리시간 0.023초

Experiments of a Novel Magnetic Levitation Stage for Wide Area Movements

  • Jeon, Jeong-Woo;Caraiani, Mitica;Oh, Hyeon-Seok;Kim, Sung-Shin
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.558-563
    • /
    • 2012
  • In this paper, a novel planar type magnetic levitation system without other assistant devices is proposed and it can move with 6 degree of freedom (X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$) in wafer size as well as in nano scale positioning.The mover is composed with 2-D Halbach permanent magnet array and the stator is composed with $10{\times}10$ coil arrays.It was composed in laboratory and tested with short stroke (4 [mm]) and long stroke (160 [mm])movements. The errors of short movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}3urad$, ${\pm}2urad$, ${\pm}1urad$]The errors of long stroke movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}1.5urad$, ${\pm}2urad$, ${\pm}0.5urad$].

Study the Properties of Silicon Nitride Films prepared by High Density Plasma Chemical Vapor Deposition

  • Gangopadhyay, Utpal;Kim, Do-Young;Parm, Igor Oskarovich.;Chakrabarty, Kaustuv;Kim, Chi-Hyung;Shim, Myung-Suk;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1127-1130
    • /
    • 2003
  • The characteristics of silicon nitride films deposited in a planar coil reactor using a simple high-density inductively coupled plasma chemical vapor deposition technique have been investigated. The process gases used during silicon nitride deposition cycle were pure nitrogen and a mixture of silane and helium. It has been pointed out that the strong H-atom released from the growing SiN film and Si-N bond healing are responsible for the improved electrical and passivation properties of SiN.

  • PDF

태양광 발전에 의한 비접촉 방식 저 전력 에너지 전송회로에 관한 연구 (A Study on Low Power Energy Transfer Circuits of the Non Contact Method by means of Solar Generation)

  • 황락훈;나승권;김종래;최기호;김진선
    • 한국항행학회논문지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2014
  • 본 논문은 무선 전력 전송에 관한 이론을 토대로 송신부와 수신부의 두 개의 평면 코일 사이의 자기 유도 원리의 다양한 조건 변화에 따른 무 접촉 무선 전력 전송에 관한 연구이다. 실험은 무 접촉 방식으로 전력을 전송 할 수 있는 송신부인 1차 측 코일과 수신부인 2차 측 코일 및 하프브리지 직렬 공진 컨버터를 적용한 무선 전원 장치의 송신부 회로와 수신부회로의 출력 전압 및 전원을 계산할 수 있는 환경을 마련해 주었다. 송신부의 유도 결합 공진 컨버터의 주 전원은 태양광 전지 모듈과 대체 광원으로서 인공 광원(할로겐 램프)을 이용하여 전기 에너지로 변환 시켜 사용하였으며 태양광 발전으로부터 공급받은 24 V 전원을 무선 전력 전송 장치를 위한 입력 전원으로 사용하였다. 실험 결과, 전달 받은 전력은 수신부 회로에서 조명을 밝히거나 배터리를 충전하는데 사용된다. 그리고 송신부의 출력 측에서 측정을 통해 수신부의 입력 전력과 비교하여 무선 전력 전송 효율은 약 70~89%로 나타났다. 또한 이 논문을 위해서, 무선 전력 전송 시 이물질이 간섭하였을 때, ID 검증 방식과 전압의 위상차 비교 방법을 통해 효율성 실험을 하였다.

유도방식 무선충전기용 송수신 장치간 정렬상태 검출기법 (The method of alignment detection between Tx and Rx set in wireless inductive charger)

  • 이상곤;김재명
    • 한국위성정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.90-96
    • /
    • 2014
  • 본 논문은 무선충전기에 있어서 효율 증대 기법에 관한 것으로, 송수신 장치간 정렬상태를 수신 장치인 스마트폰에 표시할 수 있는 방법을 제시한다. 구현된 무선충전기는 세계 표준인 WPC( Wireless Power Consortium ) 방식을 기반으로 되어 있어 수 100kHz 이하의 주파수로 동작하고 누설 자속을 최소화할 수 있도록 자기장 차폐제를 사용한 송수신 코일 구조를 갖는다. 송수신 장치의 정렬 상태를 확인할 수 있는 종래 방식은 수신단 코일의 수신 레벨만을 표시하는 단순 방식이지만 본 방식은 수신 장치의 위치까지 알 수 있어 보다 진보된 방식이라 할 수 있다. 무선 충전기 송수신 장치의 정렬상태 검출을 위하여 수신 코일의 위치변화와 자기장 세기가 서로 선형관계에 있음을 확인하고 삼각측량법을 이용하여 이 선형관계가 위치 정보로 변환될 수 있음을 보였다. 실험을 통하여 선형관계에 영향을 미칠 수 있는 요소들을 분석하고 이 요소들을 최적화한 상태에서의 선형 특성을 가질 수 있음을 보였다.

평면형 마이크로인덕터의 시작에 관한 연구 (Trial Maunfacture of Planar Type Micro Inductors)

  • 김종오;강희우;김영학;김동연;오호영
    • 한국자기학회지
    • /
    • 제6권6호
    • /
    • pp.367-374
    • /
    • 1996
  • 자기소자중 가장 기본이 되는 박막인덕터의 제작에 관한 연구를 수행하기 위하여, photolitho-graphy와 에칭공정을 도입하고, 도체간격 및 도체폭이 수십 $\mu\textrm{m}$, 도체코일 턴수가 각각 13회와 20회, 크기가 $4\;mm{\times}4\;mm$인 공심형 박막인덕터를 제작하였다. 이것을 마이크로스트립선로에 정착하고, network analyzer로 주파수 1 MHz ~ 1 GHz에서 신호의 반사계수법을 이용하여 간편하고 비교적 정확한 측정을 하였다. 특히, 공정이 간단한 습식 에칭공정을 도입하여, 안정된 에칭기술을 통해 양호한 미세패턴구조를 얻었다. 박막인덕터의 특성은, 크기가 같을때, L 및 Q값은 spiral형이 meander형 보다 큰 값을 갖는 반면, 공진주파수는 인덕턴스의 증가에 의한 영향으로 spiral형이 meander형보다 감소하였다.

  • PDF

슬리브 구조를 갖는 모노폴 안테나의 활용분야에 따른 설계와 동향분석 (Design and Trend Analysis According to the Application Field of Monopole Antenna with Sleeve Structure)

  • 강상원;변미경;이신희;최광제
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권5호
    • /
    • pp.135-141
    • /
    • 2020
  • 본 논문은 다양하게 적용 가능한 슬리브 구조를 갖는 모노폴 안테나 자료를 정리한 것이다. 슬리브 모노폴 안테나는 광대역 특성을 갖고 다주파수용으로 사용된다. 슬리브 모노폴 안테나는 복사기(radiator)인 수직 도체부분과 동축 케이블과 같은 구조를 갖는 슬리브(sleeve)로 구성되어져 있다. 슬리브는 복사기와 개방 스터브 동작을 한다. 슬리브 길이는 안테나 전체 길이의 1/3~2/3로 되어야 한다. 슬리브 구조를 갖는 모노폴 안테나는 차량용 와이퍼 안테나에 적용 가능하다. 더불어, 로딩 코일을 이용한 광대역 슬리브 안테나, ISM 밴드용 광대역 프린티드 슬리브 모노폴 안테나, 갭 슬리브와 이중 슬리브, 하프 커팅을 이용한 UWB 평면형 모노폴 안테나에 적용한 사례를 구조와 광대역 측면에서 정리 분석하였다.

스크린 프린팅 공정에 의해 제조된 비데용 Ag-Pd 봉형 발열체의 내구성 및 물성 평가 (Durability and Characteristics of Ag-Pd Rod Heater for Bidet Fabricated by Screen Printing Process )

  • 박태웅;현다은;김익수;이성철;이연숙;김용남;이동원;오종민
    • 한국전기전자재료학회논문지
    • /
    • 제36권1호
    • /
    • pp.81-87
    • /
    • 2023
  • Heaters using the resistance heating principle are used in various industrial fields that require heat and are also essentially used in bidet among small home appliances. A planar heater and a coil-inserted heater mounted on a conventional commercially used bidet have disadvantages and limitations of complicated manufacturing process and local heating. In this study, silver-palladium (Ag-Pd) powder material was used for a screen-printing process that is more advantageous in achieving simplification than the existing process, and a rod-type heater for bidet was manufactured. The on-off cycle test under actual conditions was conducted to confirm the durability and the capability of the fabricated heater, and the fabricated heater operated more than 2,600 on-off cycles, which means it could be applied for a commercial product. In addition, through the on-off cycles under harsh conditions, the cause of failure was identified after the test that the durability limit temperature of the heater was 850℃. Through Ag-Pd rod heater in this study, it is expected to contribute to the efficient development of electrode materials for heaters and the improvement of the durability of heaters in the future.

몰드변압기의 보이드 결함 크기 판별 (Identification of Void Diameters for Cast-Resin Transformers)

  • 정기우;김성욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.570-573
    • /
    • 2022
  • 본 논문에서는 신경망 모델을 적용한 몰드변압기의 보이드 결함 크기 판별에 관한 연구를 수행하였다. PCB 기반의 로고우스키 코일형 부분방전 센서를 제작하여 부분방전 신호를 측정하였고, 보이드에 의한 부분방전 결함을 모의하기 위한 PD 전극계를 제작하였다. 또한 보이드는 원통형 모양의 알루미늄 틀을 제작하여 에폭시가 경화되는 과정에서 실린지를 삽입하고 공기를 주입하여 서로다른 직경을 가지는 4개의 시편을 제작하였다. 보이드 결함 크기 판별을 위해 부분방전 전하량, 방전 펄스 수, 위상 분포의 부분방전 특성 파라미터를 추출하여 Labview 기반의 VI (Virtual Instrument)로 역전파 알고리즘을 설계하였다. 실험 결과로부터 제작된 알고리즘은 90%이상의 판별률로 결함의 직경크기를 구분할 수 있었다. 본 연구의 결과는 현장에서 PD 측정 시 몰드변압기의 유지보수 및 절연물 교체의 근거 자료로 활용될 수 있을 것으로 판단된다.

  • PDF

Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해 (Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases)

  • 류영환;구은회;정재은;동경래;최성현;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선 (Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination)

  • 이재흔;김현진;임인철
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.307-314
    • /
    • 2015
  • 유방 자기공명영상검사 시 확산강조영상에서 발생하는 심장과 폐에 의한 불수의적 움직임 인공물과 감소된 영상영역 에코평면영상기법으로 발생하는 둘러겹침 인공물을 추가적인 사전포화기법을 사용하여 이를 저감화시키고자 하였다. 2014년 08월 1일부터 11월 30일까지 여성 환자 38명을 대상으로 하였으며 사용 장비로는 유방 검사에 최적화된 3.0T와 유방 전용 코일을 사용하였다. 영상의 평가와 분석은 정량적, 정성적 분석을 하였으며 통계적 유의성은 Paired T-test와 Wilcoxon rank test를 하였다. 결과적으로 추가적인 사전포화펄스의 사용으로 정량적인 평가에서는 병변에서 15.69%, 병변 근접 부위에서 13.72%, 지방에서 20.63%의 증가를 보였으며, 대조도 대 잡음비의 경우는 병변과 병변 근접 부위에서 10.58%, 병변과 지방 부위에서 12.03%의 증가로 나타났다. 정성적인 평가에서는 확산경사계수 0에서 22.05%, 1000에서 21.42%, 현성확산계수에서 16.10%의 증가로 나타났으며, 통계적 평가에서는 신호 대 잡음비와 대조도 잡음비, 확산경사계수와 현성확산계수에서 모두 유의한 결과로 나타났다(p<0.05). 따라서 사전포화펄스의 추가적인 사용으로 유방 자기공명영상 검사에서 확산강조영상 획득 시 위상 부호화 방향으로 발생하는 불수의적 움직임 인공물과 둘러겹침 인공물이 감소가 되어 최적의 영상을 얻을 수 있을 것으로 판단된다.