• Title/Summary/Keyword: Plan Variation

Search Result 323, Processing Time 0.034 seconds

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Estimation and evaluation of irrigation water need using net water consumption concept in Jeju Island (순물소모량 개념에 의한 제주도 농업용수 수요량 산정 및 평가)

  • Kim, Chul Gyum;Kim, Nam Won
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.503-511
    • /
    • 2017
  • In order to estimate the demand for water resources planning and operation, methodology for determining the size of water supply facilities has been mainly applied to agricultural water, unlike living and industrial water, which reflects actual usage trends. This inevitably leads to an overestimation of agricultural water and can lead to an imbalance in the supply and demand of each use in terms of the total water resources plan. In this study, the difference of approaches of concept of net consumption was examined in comparison with the existing methodology and the characteristics of agricultural water demand were analyzed by applying it to whole Jeju Island. SWAT model was applied to estimate the amount of evapotranspiration, which is a key factor in estimating demand, and watershed modeling was performed to reflect geographical features, weather, runoff and water use characteristics of Jeju Island. For the past period (1992~2013), demand of Jeju Island as a whole was analyzed as 427 mm per year, and it showed a relatively high demand around the eastern and western coastal regions. Annual demand and seasonal variation characteristics of 10 river basins with watershed area of $30km^2$ or more were also analyzed. In addition, by applying the cultivated area of each crop in 2020 in the future, it is estimated that the demand corresponding to the 10-year frequency drought is 54% of the amount demanded in the previous research. This is due to the difference in approach depending on the purpose of the demand calculation. From the viewpoint of water resource management and operation, additional demand is expected as much as the net consumption. However, from the actual supply perspective, it can be judged that a facility plan that meets the existing demand amount is necessary. In order to utilize the methodologies and results presented in this study in practice, it is necessary to make a reasonable discussion in terms of policy and institutional as well as engineering verification.

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.

A Study on the Successful Case of Brand Renewal through American National Brand 'C' Company's Marketing Strategy (미국(美國) 내셔널브랜드 C사(社)의 마케팅전략(戰略)을 통한 브랜드리뉴얼 성공사례(成功事例) 연구(硏究))

  • Koh, Hee-Sook
    • Journal of Fashion Business
    • /
    • v.6 no.1
    • /
    • pp.137-154
    • /
    • 2002
  • It's not easy to renew old brand of over 50 years history to the tastes of new consumer of our time. Most of national brands that has a history of some 20 years in Korea have strove for continuation and growth of brand to no avails, which can be taken as a good example of current situation. For instance, C company, one of the National brand of US which has a history of 51 years, has made its position secure as a fashion group and based itself on a sound foundation by establishing new marketing strategy and completing successful brand renewal in the process of strategic M&A with Italian company. Those successful marketing strategies are as follows. 1) they regarded both market and consumer oriented marketing activity as company's highest priority strategy and put great emphasis upon concentration on target market and reestablishment of brand image of business casual wear. 2) Setting up and operating planning team composed of merchandizer alone in Milano, they set the direction of plan on the basis of concentrated research on potential item in market according to thorough market research done by buying office in Korea, branch office in Hong Kong and buyer in US prior to blueprint planning for season. 3) Great emphasis was placed on business which focused on intensive presentation of basic key item for apparel career women who are main consumer group in the midium-low prices market in US and on supplementation of size and color. they named this line 'collectibles' and helped their customer develop their own clothes plan without worrying about the change of color and fabric by supporting same fabric and color throughout the year and enabled them to add variation easily by supplementing new trend item. 4) Company set black as a main color that lots of apparel career women find easy to care and to express their own image and presented them with pebble which belongs to navy and beige and added fashion color such as wine and brown etc as season goes by. They constructed basic line in order for their customers to coordinate purchased item with new one or to add them to present collection, and to achieve efficient sale by setting up strategy which allows this cross coordination and changing pattern occasionally. 5) Though basic jacket for 99$, short slim skirt for 49$ are products within midium-low prices range, in the material planning stage aiming at production of item that has both resonable function appealing to consumer and is fashionable, synthetic material had to be used as a main source due to price competitiveness. Despite this situation, considering comfortable sense of fit and refined drape of silhouette that has no sign of cheap material, whole collectible line was divided into two items, which contributed to reduction of cost. In case of material that is composed of triacetate and polyester in 70 to 30 ratio, was used up to 4 million yard, which allowed drastic curtailment of cost accompanied by concentration. In case of 'collectibles' line, using Korean material mainly, C company chose to have their product sewed in Southeast Asian countries where transportation is well developed and both productivity and quality verified by operating global production system which aiming at cutdown of cost through outsourcing production from the country where labor cost is low and getting finished product. Polarization between present consumers telling us that consumers with the mind of middle classes in the past no longer exists between consumers who seek after only fine article of highest quality and wise consumers who are sensible enough to judge bubble on correlation between price and quality. To cope with this change in new consumer mind, apparel makes changing their policy so as to produce item that has reasonable quality and falls within affordable price range anywhere in the world. and they're striving to get out of difficult situation by operating global marketing strategy which stresses separation of planning, production and sale and sensibility of fashion shared worldwide. The marketing strategy of C company can be exemplified as a successful one.

A Study on Vulnerability Assessment and Prioritizing Sectors to Support Adaptation Strategy to Climate Change - Case Study of Gangwon Province - (기후변화 적응대책 수립 지원을 위한 취약성 평가 및 부문별 우선순위 선정 방안 연구 - 강원도 사례를 중심으로 -)

  • Oh, Suhyun;Lee, Woo-Kyun;Yoo, Seongjin;Byun, Jungyeon;Park, Sunmin;Kwak, Hanbin;Cui, Guishan;Kim, Moonil;Jung, Raesun;Nam, Kijun;Shin, Donghee
    • Journal of Climate Change Research
    • /
    • v.3 no.4
    • /
    • pp.245-257
    • /
    • 2012
  • Vulnerability assessment has been required for establish climate adaptation plan to prevent damage from climate change. In this study we assessed vulnerability with 1 km resolution and determined which sectors have the highest priority in each municipality of Gangwon province based on the result of vulnerability assessment. All sectors of vulnerability assessment are composed of three criteria; sensitivity, exposure and adaptation capacity. And suitable indicators of each sector were selected and spatial data set was prepared using GIS. Priority of vulnerability was classified with the degree of vulnerability in present and variation in vulnerability between present and future. The results of vulnerability assessment were different among municipalities due to the contribution of indicators. Present and future trends in vulnerability showed similar results but high vulnerable area was predicted to expand in the future. In addition increase in temperature led whole area to be more vulnerable generally. The result of prioritizing sectors of vulnerability indicated the most considerable sectors within a municipality. Also, the municipalities which have similar geographic, climatic and social conditions tended to be classified as the same priority class. The method of vulnerability assessment and determining priorities suggested in this study could be used to support decision makers to establish adaptation plan of local area.

Microbiological Hazard Analysis for HACCP System Application to Vinegared Pickle Radishes (식초절임 무의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • This study has been performed for 150 days from February 1 - June 31, 2012 aiming at analyzing biologically hazardous factors in order to develop HACCP system for the vinegared pickle radishes. A process chart was prepared as shown on Fig. 1 by referring to manufacturing process of manufacturer of general vinegared pickle radishes regarding process of raw agricultural products of vinegared pickle radishes, used water, warehousing of additives and packing material, storage, careful selection, washing, peeling off, cutting, sorting out, stuffing (filling), internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, E. coli O157:H7, Clostridium perfringens, Yeast and Mold before and after washing raw radishes, Bacillus cereus was $5.00{\times}10$ CFU/g before washing but it was not detected after washing and Yeast and Mold was $3.80{\times}10^2$ CFU/g before washing but it was reduced to 10 CFU/g after washing and other pathogenic bacteria was not detected. As a result of testing microorganism variation depending on pH (2-5) of seasoning fluid (condiment), pH 3-4 was determined as pH of seasoning fluid as all the bacteria was not detected in pH3-4. As a result of testing air-borne bacteria (number of general bacteria, colon bacillus, fungus) depending on each workplace, number of microorganism of internal packing room, seasoning fluid processing room, washing room and storage room was detected to be 10 CFU/Plate, 2 CFU/Plate, 60 CFU/Plate and 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of general bacteria and colon bacillus was represented to be high as 346 $CFU/Cm^2$ and 23 $CFU/Cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, colon bacillus was not detected in all the specimen but general bacteria was most dominantly detected in PP Packing machine and Siuping machine (PE Bulk) as $4.2{\times}10^3CFU/Cm^2$, $2.6{\times}10^3CFU/Cm^2$, respectively. As a result of analyzing above hazardous factors, processing process of seasoning fluid where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and threshold level (critical control point) was set at pH 3-4. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

The Concepts of Weight Control and Dietary Behavior in High School Seniors (고등학교 3학년생의 체중조절에 대한 인식과 관련 식행동 분석)

  • Chung, Hye-Kyung;Lee, Hae-Young
    • Journal of Nutrition and Health
    • /
    • v.43 no.6
    • /
    • pp.607-619
    • /
    • 2010
  • The purpose of this study was to identify the concepts of body image, weight control and food behavior in 520 Korean high school seniors from Seoul and Gyeonggi Province. A questionnaire survey was conducted to investigate body image, concern of weight control, experience of weight control, the first time to try weight control, plan for weight control, reasons of weight control and food behaviors related with weight control. Anthropometric parameters such as weight and height were measured. Finally, data from 497 high school seniors were used for statistical analysis. The results were as follows. Many subjects had misperceptions. Among the subjects who perceived themselves as 'fat', 57.8% were normal weight and 0.5% underweight. Among the subjects who perceived themselves as 'thin', 59.5% were normal weight, 0.9% overweight and 0.9% obese. Girls were more concerned about weight control than boys (4.20 vs. 3.66). Weight loss had been experienced by 61.5% of the subjects and weight gain by 12.8%. First weight control was attempted by 71.3% of the subject at high school and by 28.7% at middle school. The majority of subjects planned for weight control before their freshman year. The boys choose 'health' as the primary reason for weight control, whereas the girls chose 'good appearance'. The total score of food behaviors varied significantly according to BMI. Overweight and obese subjects had more desirable food behaviors than normal weight and underweight subjects (24.00, 24.06 vs. 21.92, 21.52). However, total scores of food behaviors showed no variation according to sex, weight control attempt and body image. In conclusion, the high school seniors had misconceptions about body image and weight control. They were exposed to a high risk of inappropriate weight control and food behaviors. Therefore, proper nutritional education programs need to be developed for high school seniors to prevent nutrition problems related to weight control and to maintain desirable food behaviors.