• Title/Summary/Keyword: Plain concrete

Search Result 623, Processing Time 0.025 seconds

Tensile Properties of Fiber Reinforced Concrete

  • Cho, Baik-Soon;Back, Sung-Yong;Park, Hyun-Jung
    • KCI Concrete Journal
    • /
    • v.12 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Potentially significant mechanical improvements in tension can be achieved by the incorporation of randomly distributed, short discrete fibers in concrete. The improvements due to the incorporation fibers significantly influence the composite stress - strain ($\sigma$-$\varepsilon$) characteristics. In general incorporating fibers in a plain concrete has relatively small effect on its precracking behavior. It, however, alters its post-cracking behavior quite significantly, resulting in greatly improved ductility, crack controls, and energy absorption capacity (or toughness). Therefore, a thorough understanding the complete tensile stress - strain ($\sigma$-$\varepsilon$) response of fiber reinforced concrete is necessary for proper analysis while using structural components made with fiber reinforced concrete. Direct tensile stress applied to a specimen is in principle the simplest configuration for determining the tensile response of concrete. However, problems associated with testing brittle materials in tension include (i) the problem related to gripping of the specimen and (ii) the problem of ensuring centric loading. Routinely, indirect tension tests for plain concrete, flexural and split-cylinder tests, have been used as simpler alternatives to direct uniaxial tension test. They are assumed to suitable for fiber reinforced concrete since typically such composites comprise 98% by volume of plain concrete. Clearly since the post-cracking characteristics are significantly influenced by the reinforcing parameters and interface characteristics, it would be fundamentally incorrect to use indirect tensile tests for determining the tensile properties of fiber reinforced concrete. The present investigation represents a systematic look at the failure and toughening mechanisms and macroscopic stress - strain ($\sigma$-$\varepsilon$) characteristics of fiber reinforced concrete in the uniaxial tension test. Results from an experimental parametric study involving used fiber quantity, type, and mechanical properties in the uniaxial tension test are presented and discussed.

  • PDF

Evaluation of Concrete Cone Breakout Strength of Expansion Anchors (익스팬션 앵커의 콘크리트 콘 파괴강도 평가)

  • Kim, Sung Yong;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.649-660
    • /
    • 2003
  • The paper presents an evaluation of the tensile strength of the expansion anchor that can cause failure in the concrete based on the design of the anchorage. Tests of the heavy-duty anchor and the wedge anchor that are domestically manufactured and installed in plain concrete members are conducted to probe the effects of the embedded depth, concrete strength, and anchors spacing. The design of post-installed steel anchors is presented using the Concrete Capacity Design (CCD) approach. The CCD method is applied to predict the concrete failure load of the expansion anchor in plain concrete under monotonic loading for important applications. The concrete tension capacity of the fastenings with heavy-duty anchors and wedge anchors in plain concrete predicted using the CCD method is compared with the test results. For the CCD method, a normalization coefficient of 9.94 is appropriale for the nominal concrete breakout strength of an anchor or a group of wedge anchors in tension. On the other hand, a normalization coefficient of 11.50 is appropriate for the nominal concrete breakout strength of an anchor or a group of heavy-duty anchors in tension.

Strengthening method against Overturn of Plain Concrete Gravity Pier for Open-Steel-Plate-Girder Railway Bridges (철도판형교 무근콘크리트 교각의 전도 보강기법)

  • Lee, Jun-S.;Choi, Eun-Soo;Rhee, In-Kuy;Lee, Joo-B.
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1165-1173
    • /
    • 2007
  • Open-Steel-Plate-Girder railway bridges, in general, have plain concrete gravity pier without piles at foundations. Such piers are vulnerable to be overturned against braking forces and ground shakings during an earthquake. Thus, this study suggests a strengthening method using earth anchors to improve the resistance of plain concrete gravity piers to the overturn of themselves. Also, a filed test was performed for the as-built and the strengthened pier and the test results were compared to assess the strengthening effect. The earth anchors increased the ultimated capacity for the pier's overturn. Finally, a FE analysis was conducted using nonlinear elements for soil to understand the distribution of the soil stresses for the as-built and the strengthened pier.

  • PDF

Qualities of Concrete Using Recycling Water with the Kinds and Contents of Saccaric Based Stabilizing Agent (당류계 안정화제 종류 및 혼입률 변화에 따른 회수수사용 콘크리트의 품질특성)

  • Jin, Hu-Lin;Kim, Kyung-Min;Woo, Jong-Wan;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.660-663
    • /
    • 2004
  • This paper investigate the qualities variety of concrete using recycling water under various kinds and contents of saccaric based stabilizing agent(SSA). Fluidity had little changes with the kinds and contents of SSA. Air contents of concrete with recycled water only shows the tendency. With an increase in SSA contents, air content recovered. For bleeding properties, bleeding shows to be decreased with an increase in SSA contents. The use of recycled water accelerated the setting time. However, with an increase in SSA, setting time showed the similar level of plain concrete. SSA (Btype) had better performance in enhancing compressive strength owing to loss of air content. Although the use of recycled water increased the drying shrinkage compared with that of plain concrete, it tended to decrease with an increase in SSA.

  • PDF

Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test (고성능 RC 기둥의 재하가열시험에 의한 내화 특성)

  • Kim Kyung Min;Kim Ki Hoon;Hwang Yin Seong;Lee Jae Sam;Lee Seong-Yeun;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.57-60
    • /
    • 2005
  • This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

  • PDF

Validation of 3D crack propagation in plain concrete -Part II: Computational modeling and predictions of the PCT3D test

  • Gasser, T.Christian
    • Computers and Concrete
    • /
    • v.4 no.1
    • /
    • pp.67-82
    • /
    • 2007
  • The discrete crack-concept is applied to study the 3D propagation of tensile-dominated failure in plain concrete. To this end the Partition of Unity Finite Element Method (PUFEM) is utilized and the strong discontinuity approach is followed. A consistent linearized implementation of the PUFEM is combined with a predictor-corrector algorithm to track the crack path, which leads to a robust numerical description of concrete cracking. The proposed concept is applied to study concrete failure during the PCT3D test and the predicted numerical results are compared to experimental data. The proposed numerical concept provides a clear interface for constitutive models and allows an investigation of their impact on concrete cracking under 3D conditions, which is of significant scientific interests to interpret results from 3D experiments.

Study for Curling Control of Plain Concrete in Underground Parking Lot (지하주차장 무근콘크리트 컬링제어를 위한 연구)

  • Seo, Tae-Seok;Choi, Hoon-Jae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.243-249
    • /
    • 2018
  • The study for curling control of plain concrete in underground parking lot was conducted in this study. The shrinkage reducing agent(SRA) was used to minimize the curling deformation of plain concrete in underground parking lot. For the quantitative curling control, the simplified prediction method applying the deflection theory of cantilever beam was proposed too, and the validity of prediction method was examined through the comparison between the experimental values and predictive values. In result, the curling of SRA 1.0% concrete was about 30% less than that of SRA 0.0% concrete, and the possibility of curling estimation by the simplified prediction method was confirmed through the comparison between the experimental values and predictive values.

An Application of Shrinkage Compensation Mortar in Construction Field (수축 보상 모르타르의 현장 적용 연구)

  • 김기동;정성철;송명신;이경희
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.3-10
    • /
    • 2000
  • In this study, we compared a plain mortar with the CAS-system shrinkage compensation mortar for Ondol that is Korean traditional heating system. The Ondol mortar is necessary to have properties as non-crack, fine flatness and stability for thermal changes. especially, mortar'crack prevention is to be most important property in Ondol mortar. To develope the stable material on the crack-prevention, we used to calcium-sulfo-aluminate(CSA)system in shrinkage compensation mortar. And so, we confirmed the effects of calcium-sulfo-aluminate(CSA) system for mortar's physical properties such as setting time, compressive strength and expansion ratio for crack prevention. The initial and final setting time of the CSA mortar is faster than plain mortar about 2hours. And, Compressive strength increased about 20% that plain mortar. The crack length per unit area, plain mortar is 0.426∼0.481m/m2. The Results of apartment construction field test, the shrinkage compensation mortar is excellent about the crack-reduce effect.

Prediction of chloride diffusion coefficient of concrete under flexural cyclic load

  • Tran, Van Mien;Stitmannaithum, Boonchai;Nawa, Toyoharu
    • Computers and Concrete
    • /
    • v.8 no.3
    • /
    • pp.343-355
    • /
    • 2011
  • This paper presented the model to predict the chloride diffusion coefficient in tension zone of plain concrete under flexural cyclic load. The fictitious crack based analytical model was used together with the stress degradation law in cracked zone to predict crack growth of plain concrete beams under flexural cyclic load. Then, under cyclic load, the chloride diffusion, in the steady state and one dimensional regime, through the tension zone of the plain concrete beam, in which microcracks were formed by a large number of cycles, was simulated with assumptions of continuously straight crack and uniform-size crack. The numerical analysis in terms of the chloride diffusion coefficient, $D_{tot}$, normalized $D_{tot}$, crack width and crack length was issued as a function of the load cycle, N, and load level, SR. The nonlinear model as regarding with the chloride diffusion coefficient in tension zone and the load level was proposed. According to this model, the chloride diffusion increases with increasing load level. The predictions using model fit well with experimental data when we adopted suitable crack density and tortuosity parameter.

A Study on the Properties of Concrete with the Kinds of Stabilizing Agent and Solid Content (회수수 안정화제 종류 및 고형분량 변화에 따른 콘크리트의 특성에 관한 연구)

  • Kim, Ki-Jeong;Kim, Guang-Hua;Lee, Mun-Hwan;Lee, Sea-Hyun;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.113-117
    • /
    • 2003
  • In this study is investigated the various properties of concrete with the kinds of stabilizing agent of recycling water and solid content in order to suggest a practical use of recycling water. According to the results, fluidity and air content varies slightly with the kinds of stabilizing agent and solid content, but does not make a big difference. Setting time does not differ remarkably from plain concrete at 20℃, but is shortened with an increase of solid content. Bleeding is reduced more largely in the case of S than in the case of R, and is not influenced by solid content. Compressive strength is equal or decreases in comparison with plain concrete at solid content of I and 50%, and shows the highest value at solid content of 3%. Length change by drying shrinkage is larger than plain concrete at solid content of 5%, and decreases at solid content of I and 3%. Therefore, it proves that the influence of the kinds of stabilizing agent is minute, and solid content is most effective at 3%.

  • PDF