• 제목/요약/키워드: Placements

검색결과 152건 처리시간 0.027초

Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

  • Rosa, Guillermo M.;Elizondo, Maria L.
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.155-160
    • /
    • 2014
  • Purpose: The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods: A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results: For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion: The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

한국형 아파트의 난방에너지 분석 1: 위치의 영향 (Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location)

  • 유호선;현석균;박유원;김용식;홍희기
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.101-110
    • /
    • 2004
  • This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

Silicone Stent Placement for Primary Tracheal Amyloidosis Accompanied by Cartilage Destruction

  • Ryu, Duck Hyun;Eom, Jung Seop;Jeong, Ho Jung;Kim, Jung Hoon;Lee, Ji Eun;Jun, Ji Eun;Song, Dae Hyun;Han, Joungho;Kim, Hojoong
    • Tuberculosis and Respiratory Diseases
    • /
    • 제76권6호
    • /
    • pp.292-294
    • /
    • 2014
  • Primary tracheal amyloidosis (PTA) can lead to airway obstructions, and patients with severe PTA should undergo bronchoscopic interventions in order to maintain airway patency. Focal airway involvements with amyloidosis can only be treated with mechanical dilatation. However, the PTA with diffused airway involvements and concomitant cartilage destructions requires stent placement. Limited information regarding the usefulness of silicone stents in patients with PTA has been released. Therefore, we report a case of diffused PTA with tracheomalacia causing severe cartilage destruction, which is being successfully managed with bronchoscopic interventions and silicone stent placements.

Using Spatial Ontology in the Semantic Integration of Multimodal Object Manipulation in Virtual Reality

  • Irawati, Sylvia;Calderon, Daniela;Ko, Hee-Dong
    • 한국HCI학회논문지
    • /
    • 제1권1호
    • /
    • pp.9-20
    • /
    • 2006
  • This paper describes a framework for multimodal object manipulation in virtual environments. The gist of the proposed framework is the semantic integration of multimodal input using spatial ontology and user context to integrate the interpretation results from the inputs into a single one. The spatial ontology, describing the spatial relationships between objects, is used together with the current user context to solve ambiguities coming from the user's commands. These commands are used to reposition the objects in the virtual environments. We discuss how the spatial ontology is defined and used to assist the user to perform object placements in the virtual environment as it will be in the real world.

  • PDF

30대 남성 슬림 핏 재킷원형 패턴설계 제2보 - 6패널 재킷을 중심으로 - (Patternmaking of Men's Slim-fit Jacket Sloper in Their 30's Part 2 -Focusing on 6-panel jacket-)

  • 김명옥
    • 한국의류산업학회지
    • /
    • 제17권1호
    • /
    • pp.93-101
    • /
    • 2015
  • This study aims to suggest the patternmaking method of men's slim-fit six-panel jacket sloper in their 30's. The researcher collected four kinds of existing slopers and carried out appearance evaluations twice. The researcher's sloper was developed by modifying and supplementing the existing sloper with high scores from the evaluations. The results are as follows: first, when comparing the four kinds of existing slopers, dimensions and patternmaking methods of 18 areas, especially width of back chest and side chest, were varied according to the existing slopers. Second, the researcher's sloper had excellent scores in the appearance evaluations such as placements of side line on the chest, waist, hip line, measurement in dimension from the center back hip line and from waist line, and appearance of neck line. Third, the suggested sloper are as follows: the ease on the chest is 10.5 cm, 8~10 cm extends for the jacket length, the measure in dimension from the back waist is 2.2 cm, dart intake at the back side is 4 cm, dart intake at the front side is 1.5~2 cm, and dart intake at the front waist is 1 cm. This suggested six-panel jacket sloper is expected to be useful for the various slim-fit jacket designs which have the side panels.

전력계통의 페이저 측정기 최적배치 (Optimal Placement of the Phasor Measurement Units in Power System)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

Effects of Intramuscular Electrical Stimulation Using Inversely Placed Electrodes on Myofascial Pain Syndrome in the Shoulder - A Case Series

  • Shanmugam, Sukumar;Mathias, Lawrence;Thakur, Ajay;Kumar, Dhanesh
    • The Korean Journal of Pain
    • /
    • 제29권2호
    • /
    • pp.136-140
    • /
    • 2016
  • Myofascial pain syndrome (MPS) is one of the common musculoskeletal conditions of the shoulder which may develop sensory-motor and autonomic dysfunctions at the various level of the neuromuscular system. The pain and dysfunction caused by MPS were primarily treated with physical therapy and pharmacological agents in order to achieve painfree movements. However, in recent years intramuscular electrical stimulation (IMES) with conventional electrode placement was used by researchers to maximise therapeutic values. But, in this study an inverse electrode placement was used to deliver electrical impulses intramuscularly to achieve neuro-modulation at the various level of the nervous system. Nine patients with MPS were treated with intramuscular electrode stimulation using inversely placed electrodes for a period of three weeks. All nine subjects recovered from their shoulder pain and disability within the few weeks of intervention. So, this inverse electrode placement may be more appropriate for chronic pain management.

Efficient Idle Virtual Machine Management for Heterogeneous Cloud using Common Deployment Model

  • Saravanakumar, C.;Arun, C.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권4호
    • /
    • pp.1501-1518
    • /
    • 2016
  • This paper presents an effective management of VM (Virtual Machine) for heterogeneous cloud using Common Deployment Model (CDM) brokering mechanism. The effective utilization of VM is achieved by means of task scheduling with VM placement technique. The placements of VM for the physical machine are analyzed with respect to execution time of the task. The idle time of the VMis utilized productively in order to improve the performance. The VMs are also scheduled to maintain the state of the current VM after the task completion. CDM based algorithm maintains two directories namely Active Directory (AD) and Passive Directory (PD). These directories maintain VM with proper configuration mapping of the physical machines to perform two operations namely VM migration and VM roll back. VM migration operation is performed from AD to PD whereas VM roll back operation is performed from PD to AD. The main objectives of the proposed algorithm is to manage the VM's idle time effectively and to maximize the utilization of resources at the data center. The VM placement and VM scheduling algorithms are analyzed in various dimensions of the cloud and the results are compared with iCanCloud model.

상세배치를 위한 확장된 인터리빙 기법 (An Extended Interleaving Technique for Detailed Placement)

  • 오은경;허성우
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제33권8호
    • /
    • pp.514-523
    • /
    • 2006
  • 본 논문에서는 상세배치를 개선할 수 있는 확장된 인터리빙 기법을 제안한다. 기존의 행 -기반 인터리빙 기법은 한 행 내에서만 셀의 위치를 이동할 수 있는 제약이 있으며, 모든 셀이 여백 없이 인접해 있다는 가정 하에 적용 가능하였다. 본 논문에서 제안한 확장된 인터리빙 기법은 그런 제약을 극복하여 셀이 다른 행간에도 이동할 수 있도록 하였고, 또한 셀들 사이에 여백이 있는 경우에도 인터리빙 기법을 적용할 수 있도록 하였다. 반도체 설계 회사에서 사용 중인 CAD 툴에 의해 수렴된 상세배치를 제안된 인터리빙 기법을 이용하여 추가로 개선시킨 결과 HP(half perimeter)가 평균 9.5% 가 개선되었다.

Alveolar ridge preservation of an extraction socket using autogenous tooth bone graft material for implant site development: prospective case series

  • Kim, Young-Kyun;Yun, Pil-Young;Um, In-Woong;Lee, Hyo-Jung;Yi, Yang-Jin;Bae, Ji-Hyun;Lee, Junho
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.521-527
    • /
    • 2014
  • This case series evaluated the clinical efficacy of autogenous tooth bone graft material (AutoBT) in alveolar ridge preservation of an extraction socket. Thirteen patients who received extraction socket graft using AutoBT followed by delayed implant placements from Nov. 2008 to Aug. 2010 were evaluated. A total of fifteen implants were placed. The primary and secondary stability of the placed implants were an average of 58 ISQ and 77.9 ISQ, respectively. The average amount of crestal bone loss around the implant was 0.05 mm during an average of 22.5 months (from 12 to 34 months) of functional loading. Newly formed tissues were evident from the 3-month specimen. Within the limitations of this case, autogenous tooth bone graft material can be a favorable bone substitute for extraction socket graft due to its good bone remodeling and osteoconductivity.