• 제목/요약/키워드: Placement standard

검색결과 177건 처리시간 0.021초

Effect of Electromagnetic Navigated Ventriculoperitoneal Shunt Placement on Failure Rates

  • Jung, Nayoung;Kim, Dongwon
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권3호
    • /
    • pp.150-154
    • /
    • 2013
  • Objective : To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. Methods : All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. Results : A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). Conclusion : The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

임플란트 식립을 위해 블록형 자가골이식을 이용한 퇴축된 치조골의 재건 (Atrophic Alveolar Ridge Augmentation using Autogenous Block Bone Graft for Implant Placement)

  • 지영덕;조진형
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.161-171
    • /
    • 2006
  • Endosseous implants have restored normal function and dental health to many patients. When implants were introduced as an effective treatment modality, their efficacy was limited by the amount of available bone. Today, various grafting procedures can surgically create bone width and volume. Implants can be placed in more ideal locations for successful prosthetic reconstruction. The use of autogenous bone grafts represents the "gold standard" for bone augmentation procedures. Either intraoral or extraoral sites may be considered for donor sites. Alveolar ridge augmentation using autogenous bone block, can be done during implant placement or staged with implant placement, after bone graft healing. In the staged technique, a better implant positioning and the use of wide diameter implants are possible. Alveolar ridge augmentation using autogenous block graft is a predictable way of treatment, for the atrophic alveolar ridge before implant placement. The cases presented in this article clinically demonstrate the efficacy of using a autogenous block graft in generating effective new bone fill for dental implant placement.

믹싱기 추가에 따른 현장가열 재생 아스팔트 혼합물의 물성평가 (Evaluation of the Properties of a Hot In-Placement Recycled Asphalt Mixture as an Adding Mixer)

  • 이강훈;박재영;이화선;김용주;이재준
    • 한국도로학회논문집
    • /
    • 제20권1호
    • /
    • pp.97-105
    • /
    • 2018
  • PURPOSES : Asphalt concrete pavement is damaged by various causes such as traffic and environmental loads. The distressed pavement should be maintained by various methods to provide a comfortable and safe pavement for the driver. This study evaluates the effect of adding a mixing procedure to enhance the mixture quality in the hot in-placement recycled asphalt pavement method, which is an asphalt-pavement maintenance method. METHODS : Various test methods such as Marshall stability and dynamic stability, were employed to estimate the recycled asphalt mixture with and without an additional mixing, using the hot in-placement recycled asphalt pavement method. RESULTS : The mixture samples used in this study were taken before and after the addition of the mixer in the hot in-placement recycled asphalt pavement method (HIR) at field construction sites in GongJu and JinJu in South Korea. The test results of both mixtures satisfied the asphalt-mixture standard specifications. CONCLUSIONS : This study confirmed that adding a mixer in the HIR method results in a well-mixed new asphalt mixture, rejuvenator, and reclaimed asphalt mixture.

다단 그래프 모델을 이용한 빠른 표준셀 배치 알고리즘 (A One-Pass Standard Cell Placement Algorithm Using Multi-Stage Graph Model)

  • 조환규;경종민
    • 대한전자공학회논문지
    • /
    • 제24권6호
    • /
    • pp.1074-1079
    • /
    • 1987
  • We present a fast, constructive algorithm for the automatic placement of standard cells, which consists of two steps. The first step is responsible for cell-row assignment of each cell, and converts the circuit connectivity into a multi-stage graph under to constraint that sum of the cell-widths in each stage of the multi-state graph does not exceed maximum cell-row width. Generatin of feed-through cells in the final layout was shown to be drastically reduced by this step. In the second step, the position of each cell within the row is determined one by one from left to right so that the cost function such as the local channel density is minimized. Our experimental result shows that this algorithm yields near optimal results in terms of the number of feed-through cells and the horizontal tracks, while running about 100 times faster than other iterative procedures such as pairwise interchange and generalized force directed relaxation method.

  • PDF

최적배근그룹 선정방법을 적용한 전단벽체의 자동배근 시스템 개발에 관한 연구 (The Study on the Development of Automatic Rebar Placement System Applying Selection Method of Optimum Reinforcing Bar Group on Shear Wall)

  • 조영상;김동은;진현아;장현석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.81-89
    • /
    • 2015
  • 본 연구에서는 철근콘크리트구조에서 전단벽체를 대상으로 설계단계에서부터 Set-Based Design과 계층화분석기법을 통하여 선정된 최적배근그룹을 적용한 S-BIM기반 자동철근배근시스템 제안을 목적으로 한다. 복합적인 기준에 대한 쌍대비교 분석을 통해 최적 철근배근그룹을 선정하고 BIM 소프트웨어 벤더 (Vendor)에서 제공하는 Open API를 이용하여 구조설계 알고리즘을 통한 부재의 생성 및 철근배근이 자동으로 수행될 수 있도록 하였다. 결과적으로 가중치가 가장 높은 ALT1 (0.142)의 최적철근배근그룹이 선정되었고, 이를 TS상에 생성하였다.

Enhancement of Processing Capabilities of Hippocampus Lobe: A P300 Based Event Related Potential Study

  • Benet, Neelesh;Krishna, Rajalakshmi;Kumar, Vijay
    • 대한청각학회지
    • /
    • 제25권3호
    • /
    • pp.119-123
    • /
    • 2021
  • Background and Objectives: The influence of music training on different areas of the brain has been extensively researched, but the underlying neurobehavioral mechanisms remain unknown. In the present study, the effects of training for more than three years in Carnatic music (an Indian form of music) on the discrimination ability of different areas of the brain were tested using P300 analysis at three electrode placement sites. Subjects and Methods: A total of 27 individuals, including 13 singers aged 16-30 years (mean±standard deviation, 23±3.2 years) and 14 non-singers aged 16-30 years (mean age, 24±2.9 years), participated in this study. The singers had 3-5 years of formal training experience in Carnatic music. Cortical activities in areas corresponding to attention, discrimination, and memory were tested using P300 analysis, and the tests were performed using the Intelligent Hearing System. Results: The mean P300 amplitude of the singers at the Fz electrode placement site (5.64±1.81) was significantly higher than that of the non-singers (3.85±1.60; t(25)=3.3, p<0.05). The amplitude at the Cz electrode placement site in singers (5.90±2.18) was significantly higher than that in non-singers (3.46±1.40; t(25)=3.3, p<0.05). The amplitude at the Pz electrode placement site in singers (4.94±1.89) was significantly higher than that in non-singers (3.57±1.50; t(25)=3.3, p<0.05). Among singers, the mean P300 amplitude was significantly higher in the Cz site than the other placement sites, and among non-singers, the mean P300 amplitude was significantly higher in the Fz site than the other placement sites, i.e., music training facilitated enhancement of the P300 amplitude at the Cz site. Conclusions: The findings of this study suggest that more than three years of training in Carnatic singing can enhance neural coding to discriminate subtle differences, leading to enhanced discrimination abilities of the brain, mainly in the generation site corresponding to Cz electrode placement.

Enhancement of Processing Capabilities of Hippocampus Lobe: A P300 Based Event Related Potential Study

  • Benet, Neelesh;Krishna, Rajalakshmi;Kumar, Vijay
    • Journal of Audiology & Otology
    • /
    • 제25권3호
    • /
    • pp.119-123
    • /
    • 2021
  • Background and Objectives: The influence of music training on different areas of the brain has been extensively researched, but the underlying neurobehavioral mechanisms remain unknown. In the present study, the effects of training for more than three years in Carnatic music (an Indian form of music) on the discrimination ability of different areas of the brain were tested using P300 analysis at three electrode placement sites. Subjects and Methods: A total of 27 individuals, including 13 singers aged 16-30 years (mean±standard deviation, 23±3.2 years) and 14 non-singers aged 16-30 years (mean age, 24±2.9 years), participated in this study. The singers had 3-5 years of formal training experience in Carnatic music. Cortical activities in areas corresponding to attention, discrimination, and memory were tested using P300 analysis, and the tests were performed using the Intelligent Hearing System. Results: The mean P300 amplitude of the singers at the Fz electrode placement site (5.64±1.81) was significantly higher than that of the non-singers (3.85±1.60; t(25)=3.3, p<0.05). The amplitude at the Cz electrode placement site in singers (5.90±2.18) was significantly higher than that in non-singers (3.46±1.40; t(25)=3.3, p<0.05). The amplitude at the Pz electrode placement site in singers (4.94±1.89) was significantly higher than that in non-singers (3.57±1.50; t(25)=3.3, p<0.05). Among singers, the mean P300 amplitude was significantly higher in the Cz site than the other placement sites, and among non-singers, the mean P300 amplitude was significantly higher in the Fz site than the other placement sites, i.e., music training facilitated enhancement of the P300 amplitude at the Cz site. Conclusions: The findings of this study suggest that more than three years of training in Carnatic singing can enhance neural coding to discriminate subtle differences, leading to enhanced discrimination abilities of the brain, mainly in the generation site corresponding to Cz electrode placement.

표준 치아 크기 및 배열 정보를 이용한 다중 치아 임플란트 식립계획 방안 (Planning of Multiple Tooth Implant Placement Using the Standardized Data in Teeth Size and Position)

  • 박형욱;박상진;박형준
    • 한국CDE학회논문집
    • /
    • 제20권4호
    • /
    • pp.348-356
    • /
    • 2015
  • It is important to devise methods for assisting dentists to consistently determine implant positions and directions and to accurately perform drilling tasks during dental implant surgery. In this paper, we propose a novel approach to tooth implant placement planning which deals with the determination of the positions and directions of multiple implant fixtures for a set of missing mandibular teeth and suggests the selection of the sizes and types of the implant fixtures. We combine Korean standard data in the sizes and positions of human teeth with the patient specific 3D models of mandibular jawbones, nerve curves, and neighboring teeth around the missing teeth in order to determine the positions and directions of the implant fixtures for the missing teeth. Using the geometric and spatial information of the jawbones, the teeth and the implant fixtures, we can construct the 3D models of surgical guide stents which are crucial to perform drilling tasks with ease and accuracy. Adopted in 3D simulation of dental implant placement, the approach can provide surgeon students with good educational contents. We also expect that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

ESGA를 이용한 불평형 배전계통의 커패시터 설치에 관한 연구 (A Study on Capacitor Placement Using ESGA Hybrid Approach in Unbalanced Distribution Systems)

  • 김규호;이유정;이상봉;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.316-324
    • /
    • 2003
  • This paper applied Elite-based Simplex-GA hybrid approach combined with Muptipop-GA (ESGA) to determining the location, size and number of capacitors to improve voltage profile and minimize power losses in unbalanced distribution systems. One of the main obstacles in applying GA to complex problems has been the high computational cost due to their slow convergence rate. To alleviate this difficulty, ESGA approach was developed that combines Elite-based Simplex-GA hybrid approach with Muptipop-GA. The objective function formulated consists of two terms: cost for energy losses and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as a step function due to banks of standard discrete capacities. Its efficiency was proved through the application in IEEE 13 bus and 34 bus test systems and was compared with several methods using GA.

발치 후 즉시 식립을 위한 임상적 고찰 (Clinical consideration of Immediate implant placement)

  • 오상윤
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.716-724
    • /
    • 2017
  • Past literatures stressed that when a gap occurred between smooth surface implant and alveolar bone, osseointegration was unsatisfactory at histologic examination regardless of clinical findings. Accordingly, standard surgical approach in the early days of implant surgery was to place the implant after all gap was healed. However, Botticelli et al.(2004) reported high degree of osseointegration at the gap with SLA surface implant. From then, the era of immediate implantation has begun because SLA surface implant make gap healing possible. There are two main disadvantages of immediate implantation: (1) surgical technique is sensitive for primary implant stability, (2) Implant placement at the accurate position that predicts external change of extraction wound is required. Immediate implantation has outstanding advantages in all perspectives except for the above-mentioned disadvantages. Therefore, it would be unwise to abandon the option of immediate implantation simply due to surgical difficulties. The purpose of this paper is to describe the necessity of immediate implantation and to present scientific evidence for immediate implantation and accurate implant position by literature review.

  • PDF