• Title/Summary/Keyword: Placement position and angle

Search Result 27, Processing Time 0.022 seconds

Three Dimensional Measurement of Ideal Trajectory of Pedicle Screws of Subaxial Cervical Spine Using the Algorithm Could Be Applied for Robotic Screw Insertion

  • Huh, Jisoon;Hyun, Jae Hwan;Park, Hyeong Geon;Kwak, Ho-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.376-381
    • /
    • 2019
  • Objective : To define optimal method that calculate the safe direction of cervical pedicle screw placement using computed tomography (CT) image based three dimensional (3D) cortical shell model of human cervical spine. Methods : Cortical shell model of cervical spine from C3 to C6 was made after segmentation of in vivo CT image data of 44 volunteers. Three dimensional Cartesian coordinate of all points constituting surface of whole vertebra, bilateral pedicle and posterior wall were acquired. The ideal trajectory of pedicle screw insertion was defined as viewing direction at which the inner area of pedicle become largest when we see through the biconcave tubular pedicle. The ideal trajectory of 352 pedicles (eight pedicles for each of 44 subjects) were calculated using custom made program and were changed from global coordinate to local coordinate according to the three dimensional position of posterior wall of each vertebral body. The transverse and sagittal angle of trajectory were defined as the angle between ideal trajectory line and perpendicular line of posterior wall in the horizontal and sagittal plane. The averages and standard deviations of all measurements were calculated. Results : The average transverse angles were $50.60^{\circ}{\pm}6.22^{\circ}$ at C3, $51.42^{\circ}{\pm}7.44^{\circ}$ at C4, $47.79^{\circ}{\pm}7.61^{\circ}$ at C5, and $41.24^{\circ}{\pm}7.76^{\circ}$ at C6. The transverse angle becomes more steep from C3 to C6. The mean sagittal angles were $9.72^{\circ}{\pm}6.73^{\circ}$ downward at C3, $5.09^{\circ}{\pm}6.39^{\circ}$ downward at C4, $0.08^{\circ}{\pm}6.06^{\circ}$ downward at C5, and $1.67^{\circ}{\pm}6.06^{\circ}$ upward at C6. The sagittal angle changes from caudad to cephalad from C3 to C6. Conclusion : The absolute values of transverse and sagittal angle in our study were not same but the trend of changes were similar to previous studies. Because we know 3D address of all points constituting cortical shell of cervical vertebrae. we can easily reconstruct 3D model and manage it freely using computer program. More creative measurement of morphological characteristics could be carried out than direct inspection of raw bone. Furthermore this concept of measurement could be used for the computing program of automated robotic screw insertion.

LMI Design of Multi-Objective$ Η_2/Η_\infty$Controllers for an Inverted Pendulum on the Cart Using Polytope Models (폴리토프 모델을 이용한 도립진자의 다목적$ Η_2/Η_\infty$ 제어기의 LMI 설계)

  • 이상철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.6-13
    • /
    • 2002
  • This paper deals with the linear matrix inequality (LMI) design procedures for multi-objective Η$_2$$_{\infty}$ controllers with pole-placement constraints for an inverted pendulum system modeled as convex polytopes to ensure the stabilizing regulator and tracking performances. Polytopic models with multiple linear time-invariant models linearized at some operating points are derived to design controllers overcoming the conservativeness such as a controller may have when it is designed for a model linearized at a single operating point. Multi-objective controllers are designed for polytopic models by the LMT design technique with convex algorithms. It is observed that the inverted pendulum controlled by any controller designed for each polytopic model is stabilizingly restored to the vertical angle position for initial values of larger tilt anlges.

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type (2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석)

  • Byun, Ook;Jung, Da-Un;Han, In-Hae;Kim, Seong-Ryang;Lee, Chang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.259-271
    • /
    • 2013
  • The purpose of this study was to make the stress distribution produced by simulated different load under two types of internal connection implant system (stepped and tapered type) by means of 3D finite element analysis, The finite element model was designed with the parallel placement of the one fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st molar. Two models were loaded with 200 N magnitude in the vertical direction on the central position of the crown, the 1.5 mm and 3 mm buccal offset point from the central position of the fixture. The oblique load was applied at the angle of $30^{\circ}$ on the crown surface. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual dimension. The results were as follows; 1. The loading conditions of two internal connection implant systems (stepped and tapered type) were the main factor affecting the equivalent bone strain, followed by the type of internal connections. 2. The stepped model had more mechanical stability with the reduced max. stress compared to $11^{\circ}$ tapered models under the distributed oblique loading. 3. The more the contact of implant-abutment interface to the inner wall of implant fixture, the less stress concentration was reduced.

Estimation of the Original Location of Haechi (Haetae) Statues in Front of Gwanghwamun Gate Using Archival Photos from Early 1900s and Newly Taken Photos by Image Analysis (1900년대 초반의 기록사진과 디지털 카메라 사진분석을 활용한 광화문 앞 해치상의 원위치 추정)

  • Oh, Hyundok;Nam, Ho Hyun;Yoo, Yeongsik;Kim, Jung Gon;Kang, Kitaek;Yoo, Woo Sik
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.491-504
    • /
    • 2021
  • Gwanghwamun Gate of Gyeongbokgung Palace was dismantled and relocated during the Japanese colonial period, destroyed during the Korean War, reconstructed with reinforced concrete in 1968, and finally erected at its present location in 2010. A pair of Haechi statues located in front of Gwanghwamun was dismantled and relocated several times, and the statues have yet to be returned precisely to their original positions. This study assesses the historical accuracy of their current placement under the Gwanghwamun Square Restructuring Project of the Seoul Metropolitan Government and the Cultural Heritage Administration based on archival photos from the early 1900s, and proposes a method to estimate the original positions of the Haechi through image analysis of contemporary photographs and recent digital camera photos. We estimated the original position of the Haechi before the Japanese colonial period by identifying the shooting location of the archival photo and reproducing contemporary photographs by calculating the angle and distance to the Haechi from the shooting location. The leftmost and rightmost Haechi were originally located about 9.6 m to the east and 7.4 m to the north and about 1.9 m to the west and 8.0 m to the north, respectively, of their current location indicators. As the first attempt to determine the original location of a building and its accessories using archival photos, this study launches a new scientific methodology for the restoration of cultural properties.

A STUDY ON THE FRACTURE RESISTANCE AND CHARACTERISTICS OF TEETH IN CLASS II CAVITY RESTORATIONS (2급(級) 와동(窩洞) 수복시(修復時) 치아파괴(齒牙破壞) 저항성(抵抗性) 및 귀열양상(龜裂樣相)에 관(關)한 연구(硏究))

  • Joo, Ik-Nam;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.337-348
    • /
    • 1988
  • The purpose of this study was to examine the fracture strength and characteristics of teeth with MOD cavity preparation. Freshly extracted sound maxillary premolars were cleaned and stored in normal saline solution $37^{\circ}C$ for 72 hours before experiments. The roots of teeth were embedded in a self-curing resin, and the exposed crown were maintained in a vertical position by a modelling wax in a brass ring. The MOD cavities were prepared with No. 57 carbide bur under high speed to a depth of 2.0mm and a width of 2.0mm(Fig.1). All the prepared teeth specimens were divided into 7 groups according to the mode of cavity form and restorative materials (Table 1, 2): Group I, unpreapred, intact teeth as control Group II, prepared cavity without restoration Group III, prepared teeth restored with amalgam Group IV, prepared teeth restored with composite resin (P-10) Group V, prepared teeth with beveled enamel margins restored with composite resin (P-10) Group VI, prepared teeth restored with light-cured composite resin (P-30) Group VII, prepard teeth with beveled enamel margins restored with light-cured composite resin (P-30) After placement of restorations, all of the specimens were stored in water at $37^{\circ}C$ for 72 hours before testing. All of the specimens were tested on the Instron Universal Testing machine (No. 6025) in order to evaluate the strength of fracture. One metal ball 5.0mm in diameter contacting the specimens parallel to the occlusal surface was used to in this study (Fig. 1). The fracture characteristics of the specimens were examined with naked eye and in the scanning electron microscope (JSM-20). The results obtained from this study were as follows: 1. The mean fracture strength was the highest in group VI and that in group II was the lowest. 2. The progress of crack of teeth propagated into the pulp cavity. 3. In case of the group of the restored teeth, the crack occurred to be accompanied with cuspal fracture. 4. The crack of restored teeth was initiated along the pulpo-axial line angle of the cavity.

  • PDF