• 제목/요약/키워드: Placement methods

검색결과 938건 처리시간 0.027초

교정용 브라켓의 간접 접착법

  • 차봉근
    • 대한치과의사협회지
    • /
    • 제37권7호통권362호
    • /
    • pp.530-535
    • /
    • 1999
  • Detailed finishing of the occlusion is a clinical skill that has become difficult with the development of fixed appliances. Accuracy of bracket placement definitely improves with indirect technique, Several methods for the placement of orthodontic brackets on dental casts are currently used in the indirect bonding technique. These include attachment by means of bonding resins, adhesive tapes or sticky wax. This article presents the indirect procedures of our clinic, which use paste-paste chemically cured composites. Detailed laboratory and clinical procedure for dual tray method and other application of indirect bonding will be presented.

  • PDF

Resorption of bone graft after maxillary sinus grafting and simultaneous implant placement

  • Kim, Young-Kyun;Kim, Su-Gwan;Kim, Bum-Su;Jeong, Kyung-In
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권3호
    • /
    • pp.117-122
    • /
    • 2014
  • Objectives: The purpose of this study was to evaluate the sinus bone graft resorption over 3 years after two-stage implant placement. Materials and Methods: The subjects for this study included 30 patients whose maxillary posterior ridges were too atrophic for implants. Bone-added osteotome sinus floor elevation was used in 15 maxillary sinuses, while the bone graft by lateral approach technique was used in 25 maxillary sinuses. The height from the top of the fixture to the sinus floor was estimated immediately after implant placement and the follow-up period was over 3 years. The surgery was classified with two groups: sinus bone grafting with and without autogenous bone. All implants were placed simultaneously. Results: The mean vertical bone loss was $3.15{\pm}2.95mm$. The survival rate of implants was 94.7%. Conclusion: The amount of bone resorption was not significantly associated with the surgical methods, the type of bone graft materials used, or sinus perforation during surgery.

센서최적배치 기법에 의한 원통형 구조물의 진동장 예측 (Estimation of Vibration Field of a Cylindrical Structure Derived by Optimal Sensor Placement Methods)

  • 정병규;정의봉;조대승;김국현;강명환
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.381-389
    • /
    • 2014
  • This study is concerned with the estimation of vibration-field of a cylindrical structure by modal expansion method(MEM). MEM is a technique that identifies modal participation factors using some of vibration signals and natural modes of the structure: The selection of sensor locations has a big influence on predicted vibration results. Therefore, this paper deals with four optimal sensor placement( OSP) methods, EFI, EFI-DPR, EVP, AutoMAC, for the estimation of vibration field. It also finds optimal sensor locations of the cylindrical structure by each OSP method and then performs MEMs. Predicted vibration results compared with reference ones obtained by forced response analysis. The standard deviations of errors between reference and predicted results were also calculated. It is utilized to select the most suitable OSP method for estimation of vibration field of the cylindrical structure.

유륜절개 근막밑 유방확대술: 근육밑 및 이중평면 유방확대술과 비교 (Periareolar Subfascial Breast Augmentation: Comparison with Submuscular and Dual Plane Breast Augmentation)

  • 심형보;윤상엽
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.99-104
    • /
    • 2007
  • Purpose: Subfascial augmentation mammaplasty was introduced by Dr. Graf in 2000. Subfascial placement of breast implants for augmentation was advocated as an option that has some of the advantages of both the subpectoral and subglandular placement while minimizing the disadvantages of each. The clinical experiences of 23 breast augmentations in the subfascial placement are reported. The indications for this technique are proposed. The incidence of complications is described from clinical experiences and compared with that of other methods. Methods: From January of 2004 through December of 2005, 23 patients underwent periareolar subfascial augmentation mammaplasty. The mean postoperative follow-up time was 8 months. Results: In comparing the results of the subpectoral augmentation group(57 patients) with those of the dual plane(124 patients) and subfascial groups(23 patients), the total rate of complications didn't represented the significant difference. The benefits of this technique include avoiding hematoma(as seen in the dual plane) and muscle action(in the subpectoral), and minimizing postoperative chest pain(inherent to subpectoral), and the ability to correct ptosis. And also this subfascial technique can be used for changing the plane from submuscular to subfascial in case of the reoperations. Conclusion: We're thinking that the periareolar subfascial augmentation mammaplasty would be the very useful tool for the primary and secondary breast augmentations.

임프란트 식립오류가 최종 보철물의 성공에 미치는 영향: 구강악안면외과의사에 의해 식립된 치과임프란트에 대한 보철의사의 주관적 평가 (Influence of implant misplacement on the success of the final prosthesis: Subjective evaluation by a prosthodontist of dental implants placed by an oral and maxillofacial surgeon)

  • 김영균;황정원;이효정;여인성;윤필영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.437-441
    • /
    • 2009
  • Purpose: In many cases, the erroneous placement of a dental implant brings about undesirable results. Here, the effect of dental implant placement on the success of the final prosthesis was evaluated from the point of view of the prosthodontist. Materials and Methods: All surgical operations were performed by the same oral surgeon with the same surgical protocol and all prosthodontic procedures were performed by the same prosthodontist. The problems faced by the prosthodontist, their causes, and their effect on prosthesis success were identified. The success of the final prostheses was evaluated by the same prosthodontist. Results: Only 53% (238 implants in 105 patients) of dental implants were not associated with prosthodontic problems. Multiple implant placement (more than three implants) was associated more frequently with prosthodontic problems. Conclusions: The data indicate that the satisfactory construction of a prosthesis is highly dependent on the placement of the dental implant in the best possible position. It is strongly recommended that the oral surgeon and the prosthodontist engage in pre-operative discussions to establish a top-down treatment plan, as this will improve implant placement and ultimately the success of the prosthesis.

치조골신장 부위에 식립된 임프란트 주위의 골형성에 관한 연구 (A HISTOMORPHOMETRIC STUDY OF BONE FORMATION AROUND IMPLANTS PLACED AFTER VERTICAL ALVEOLAR DISTRACTION IN THE DOG MEDEL)

  • 박종오;류동목
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.312-321
    • /
    • 2007
  • Purpose: Distraction osteogenesis has been applied to the maxillofacial implantology and good experimental and clinical results have been reported. However, histologic studies of implants placement on distraction osteogenesis of atrophic alveolar ridges are scarce. In this study, we compare the bone formation between in the transport part and in the distraction part by histomorphometric analysis. Materials & methods: Three adult beagle dogs were served as experimental subjects. The 2 premolars and 1st molar were extracted on the Lt. side of mandible in each beagle dog. After one month later, osteotomy was performed and distraction device was adapted. Distraction was performed with gradual incremental separation of two bone pieces at a rate of 1.0mm per day for 5 days. During consolidation phase, new bone was formed in the distraction zone between the separated bone pieces. 5 weeks after distraction phase, 3 implants were placed in each beagle dog. The implants were inserted through transport part and distraction part and inferior basal bone. The animals were sacrificed at 2 weeks, 4 weeks, and 12 weeks after implant placement. BIC and BA of implants on distraction part and transport part were measured histomorphometrically. Results: BIC, BA increased after implant placement as time goes by passes and new bone formation was slightly higher in transport part than in distraction part at 2 weeks, 4 weeks after implant placement. At 12 weeks after implant placement, BIC, BA of were 74%, 61% in transport part and 77%, 59% in distraction part, therefore there were no difference in BIC and BA between transport part and distraction part at 12 weeks after implant placement.

치근단 병소를 갖는 발치와에 즉시 임플란트 식립 시 비흡수성 차폐막이 치조골의 흡수에 미치는 영향에 관한 연구 (The effect of non-resorbable barrier membrane on the change of buccal and lingual alveolar bone in immediate implant placement into periapically infected extraction sockets)

  • 신승윤;양승민;계승범
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.71-76
    • /
    • 2009
  • Purpose: Many researches showed loss of alveolar bone in fresh extraction socket and even in case of immediate implant placement. The aim of this study was to evaluate the effect of non-resorbable barrier membrane on the change of buccal and lingual alveolar bone in immediate implant placement into periapically infected extraction sockets. Materials and methods: Immediate implants were placed into artificially induced periapical lesion of mandibular premolars after complete debridement using buccal bone defect made by a 6mm trephine bur in 4 mongrel dogs. Before flap repositioning, a non-resorbable barrier membrane was placed on the buccal defect in the experimental group. No membrane was placed in the control group. In 12 weeks after placement, the dogs were sacrificed and undecalcified histologic specimens were prepared. The vertical distance from the smooth-rough surface interface(SRI) to gingiva, 1st bone contact and bone crest were measured in buccal and lingual side. The horizontal thicknesses of gingiva and bone at 0, 1, 2 and 3mm below SRI were measured. Results: The buccal bone was resorbed more than lingual bone in both groups and there was statistical significance(p<0.05). The distances from SRI to 1st bone contact were $2.45{\pm}2.35\;mm$ in experimental group and $4.49{\pm}3.10\;mm$ in control group. In all vertical level, lingual bone was thicker than buccal bone(p<0.05). Conclusion: Buccal bone was reduced more than lingual bone in immediate implant placement into periapically infected extraction sockets. Placement of non-resorbable barrier membrane reduced the buccal bone resorption. However there was no statistical significance.

Outcomes of Portosystemic Shunts in Children with and without Liver Transplantation

  • Hamza Hassan Khan;Stuart S. Kaufman;Nada A. Yazigi;Khalid M. Khan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제27권1호
    • /
    • pp.37-42
    • /
    • 2024
  • Purpose: Limited data exist regarding outcome and morbidity associated with portosystemic shunts in the pediatric transplant population. Our study assesses the outcomes of pediatric patients who underwent a portosystemic shunt procedure, both with and without liver transplantation (LT). Methods: This study retrospectively reviewed the medical records of pediatric patients aged 0-19 years who underwent shunt placement between 2003 and 2017 at a tertiary care center. The analysis included cases of shunt placement with or without LT. Results: A total of 13 pediatric patients were included in the study with median age of 8.8 years. Among the cases, 11 out of 13 (84.6%) underwent splenorenal shunt, 1 (7.7%) underwent a mesocaval shunt, and another 1 (7.7%) underwent a Modified Rex (mesoportal) shunt. Additionally, 5 out of 13 (38.5%) patients had LT, with 4 out of 5 (80.0%) receiving the transplant before shunt placement, and 1 out of 5 (20.0%) receiving it after shunt placement. Gastrointestinal bleeding resulting from portal hypertension was the indication in all cases. A total of 10 complications were reported in 5 patients; the most common complication was anemia in 3 (23.1%) patients. At the most recent follow-up visit, the shunts were functional without encephalopathy, and no deaths were reported. Conclusion: Shunt placement plays a crucial role in the management of patients with portal hypertension. Our study demonstrates favorable long-term outcomes in pediatric patients who underwent shunt placement. Long term shunt outcomes were similar and unremarkable in patients with LT and without LT.

ESGA를 이용한 불평형 배전계통의 커패시터 설치에 관한 연구 (A Study on Capacitor Placement Using ESGA Hybrid Approach in Unbalanced Distribution Systems)

  • 김규호;이유정;이상봉;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.316-324
    • /
    • 2003
  • This paper applied Elite-based Simplex-GA hybrid approach combined with Muptipop-GA (ESGA) to determining the location, size and number of capacitors to improve voltage profile and minimize power losses in unbalanced distribution systems. One of the main obstacles in applying GA to complex problems has been the high computational cost due to their slow convergence rate. To alleviate this difficulty, ESGA approach was developed that combines Elite-based Simplex-GA hybrid approach with Muptipop-GA. The objective function formulated consists of two terms: cost for energy losses and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as a step function due to banks of standard discrete capacities. Its efficiency was proved through the application in IEEE 13 bus and 34 bus test systems and was compared with several methods using GA.

Adaptive and optimized agent placement scheme for parallel agent-based simulation

  • Jin, Ki-Sung;Lee, Sang-Min;Kim, Young-Chul
    • ETRI Journal
    • /
    • 제44권2호
    • /
    • pp.313-326
    • /
    • 2022
  • This study presents a noble scheme for distributed and parallel simulations with optimized agent placement for simulation instances. The traditional parallel simulation has some limitations in that it does not provide sufficient performance even though using multiple resources. The main reason for this discrepancy is that supporting parallelism inevitably requires additional costs in addition to the base simulation cost. We present a comprehensive study of parallel simulation architectures, execution flows, and characteristics. Then, we identify critical challenges for optimizing large simulations for parallel instances. Based on our cost-benefit analysis, we propose a novel approach to overcome the performance constraints of agent-based parallel simulations. We also propose a solution for eliminating the synchronizing cost among local instances. Our method ensures balanced performance through optimal deployment of agents to local instances and an adaptive agent placement scheme according to the simulation load. Additionally, our empirical evaluation reveals that the proposed model achieves better performance than conventional methods under several conditions.