• Title/Summary/Keyword: Placement distance

Search Result 145, Processing Time 0.025 seconds

Analysis on Line-Of-Sight (LOS) Vector Projection Errors according to the Baseline Distance of GPS Orbit Errors (GPS 궤도오차의 기저선 거리에 따른 시선각 벡터 투영오차 분석)

  • Jang, JinHyeok;Ahn, JongSun;Bu, Sung-Chun;Lee, Chul-Soo;Sung, SangKyung;Lee, Young Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.310-317
    • /
    • 2017
  • Recently, many nations are operating and developing Global Navigation Satellite System (GNSS). Also, Satellite Based Augmentation System (SBAS), which uses the geostationary orbit, is operated presently in order to improve the performance of GNSS. The most widely-used SBAS is Wide Area Augmentation System (WAAS) of GPS developed by the United States. SBAS uses various algorithms to offer guaranteed accuracy, availability, continuity and integrity to its users. There is algorithm for guarantees the integrity of the satellite. This algorithm calculates the satellite errors, generates the correction and provides it to the users. The satellite orbit errors are calculated in three-dimensional space in this step. The reference placement is crucial for this three-dimensional calculation of satellite orbit errors. The wider the reference placement becomes, the wider LOS vectors spread, so the more the accuracy improves. For the next step, the regional features of the US and Korea need to be analyzed. Korea has a very narrow geographic features compared to the US. Hence, there may be a problem if the three-dimensional space method of satellite orbit error calculation is used without any modification. This paper suggests a method which uses scalar values to calculate satellite orbit errors instead of using three-dimensional space. Also, this paper proposes the feasibility for this method for a narrow area. The suggested method uses the scalar value, which is a projection of orbit errors on the LOS vector between a reference and a satellite. This method confirms the change in errors according to the baseline distance between Korea and America. The difference in the error change is compared to present the feasibility of the proposed method.

Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant (임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.222-231
    • /
    • 2020
  • To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second surgery. The hex abutment is more useful than the non-hex abutment. EXT is particularly useful when the inter-arch space is limited. The tissue level (TL, internal butt connection) implant has a biomechanical advantage of coronal wall thickness and a biological advantage of an inherent transmucosal smooth surface. During TL implant restoration, an abutment can be selected using the abutment and fixture margins with considerations for the inter-arch space. Since no single type of implant can satisfy all the cases, it is necessary to select the appropriate type, considering the occlusal force and the bone condition.

Interspinous Implant with Unilateral Laminotomy for Bilateral Decompression of Degenerative Lumbar Spinal Stenosis in Elderly Patients

  • Ryu, Sung-Joo;Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.338-344
    • /
    • 2010
  • Objective : This study assessed the safety and efficacy of one level unilateral laminotomy bilateral decompression (ULBD) with the placement of a device for intervertebral assisted motion (DIAM) compared with one level ULBD only in elderly patients with degenerative lumbar spinal stenosis (DLSS). Methods : A non randomized prospective analysis was performed on 16 patients who underwent one level ULBD with DIAM (Group A) and 20 patients with one level ULBD only (Group B) between February 2007 and March 2008. Radiographic imaging, visual analog scale (VAS) and MacNab outcome scale were obtained before and after surgery at a mean interval of 21 months (range 17-27 months). Results : The disc height, interpedicular distance, slip distance and segmental lordotic angle were similar between two groups. In the group A, there was no significant difference between the pre- and post-operative imaging in terms of the sagittal balance and disc height. Both groups showed significant improvement in the clinical outcomes. In addition, there was significantly less low-back pain in the group A than in the group B at the last follow up, while the clinical improvement of the leg pain and MacNab outcome scale showed no significant difference in the two groups. There were no major complications or DIAM associated complications. Conclusion : ULBD with DIAM is a safe and efficacious treatment for selective elderly patients with DLSS, particularly for relieving low back pain comparing to ULBD. ULBD with DIAM did not alter the disc height or sagittal alignment at the mean 21 months follow-up interval.

The Morphometric Study for the Rolandic Fissure

  • Choi, Jin-Gu;Bae, Hack-Gun;Sim, Jae-Jun;Park, Heung-Ki;Sim, Ki-Bum;Choi, Soon-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.3
    • /
    • pp.171-176
    • /
    • 2007
  • Objective : The purpose of this study was to characterize the Rolandic fissure[Rf] and was to identify the Rf using the surface bony landmarks which can be usually exposed on craniotomy. Methods : After morphological evaluation of the Rfs using 21 Korean adult formalin fixed cadavers, craniometric measurement was carried out from the surface bony landmarks of nasion, glabella, bregma, and lambda. Results : The Rfs of both hemispheres did not show the mirror image. The Rfs ran forward and downward toward the sylvian fissure keeping the mean angle of $67^{\circ}$ from mid-sagittal line as elongated S-shape in left and the elongated reverse S-shape in right hemisphere. Connections between the Rf and the longitudinal fissure and between the Rf and the sylvian fissure were found in 3 [7.1%] and 2 [4.8%] of 42 hemispheres, respectively. Most Rfs extended superiorly to 2-3mm lateral to the most superomedial surface of hemispheres and extended inferiorly to 3-5mm superior to the sylvian fissures. The mean distances from the nasion, glabella, bregma, and lambda to the most superomedial aspect of the Rf were $18.8{\pm}0.9cm,\;16.6{\pm}0.8cm,\;5.2{\pm}0.6cm$, and $6.9{\pm}1.0cm$, respectively. The mean distance measured between the Rf and the nasion using traditional method was $18.4{\pm}0.6cm$. Conclusion : The distance between the Rf and the nasion roughly correspond within the range of mean 4 mm compared with that measured by the traditional measurement. These data may be more helpful to delineate the Rf after the placement of drapes for craniotomy.

New Technical Tip for Anterior Cervical Plating : Make Hole First and Choose the Proper Plate Size Later

  • Park, Jeong-Yoon;Zhang, Ho-Yeol;Oh, Min-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.212-216
    • /
    • 2011
  • Objective : It is well known that plate-to-disc distance (POD) is closely related to adjacent-level ossification following anterior cervical plate placement. The study was undertaken to compare the outcomes of two different anterior cervical plating methods for degenerative cervical condition. Specifically, the new method involves making holes for plate screws first with an air drill and then choosing a plate size. The other method was standard, that is, decide on the plate size first, locate the plate on the anterior vertebral body, and then drilling the screw holes. Our hypothesis was that the new technical tip may increase POD as compared with the standard anterior cervical plating procedure. Methods : We retrospectively reviewed 49 patients who had a solid fusion after anterior cervical arthrodesis with a plate for the treatment of cervical disc degeneration. Twenty-three patients underwent the new anterior cervical plating technique (Group A) and 26 patients underwent the standard technique (Group B). POD and ratios between POD to anterior body heights (ABH) were measured using postoperative lateral radiographs. In addition, operating times and clinical results were reviewed in all cases. Results : The mean durations of follow-up were $16.42{\pm}5.99$ (Group A) and $19.83{\pm}6.71$ (Group B) months, range 12 to 35 months. Of these parameters mentioned above, cephalad POD (5.43 versus 3.46 mm, p=0.005) and cephalad POD/ABH (0.36 versus 0.23, p=0.004) were significantly greater in the Group A, whereas operation time for two segment arthrodesis (141.9 versus 170.6 minutes, p=0.047) was significantly lower in the Group A. There were no significant difference between the two groups in caudal POD (5.92 versus 5.06 mm), caudal POO/ABH (0.37 versus 0.32) and clinical results. Conclusion : The new anterior cervical plating method represents an improvement over the standard method in terms of cephalad plate-to-disc distance and operating time.

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity

  • Oh, Hyun-Ju;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.283-291
    • /
    • 2018
  • Objective: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. Methods: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone-implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. Results: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. Conclusions: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root.

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

  • Park, Ji-Man;Kim, Hyun-Joo;Park, Eun-Jin;Kim, Myung-Rae;Kim, Sun-Jong
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and $30^{\circ}$ oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at $30^{\circ}$, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the $30^{\circ}$ oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.

Range-free Localization Based on Residual Force-vector with Kalman Filter in Wireless Sensor Networks (무선 센서 네트워크에서 칼만 필터를 이용한 잔여 힘-벡터 기반 Range-free 위치인식 알고리즘)

  • Lee, Sang-Woo;Lee, Chae-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4B
    • /
    • pp.647-658
    • /
    • 2010
  • Many localization schemes estimate the locations of radio nodes based on the physical locations of anchors and the connectivity from the anchors. Since they only consider the knowledge of the anchors without else other nodes, they are likely to have enormous error in location estimate unless the range information from the anchors is accurate or there are sufficiently many anchors. In this paper, we propose a novel localization algorithm with the location knowledge of anchors and even one-hop neighbors to localize unknown nodes in the uniform distance from all the one-hop neighbors without the range information. The node in the uniform distance to its all neighbors reduces the location error relative to the neighbors. It further alleviates the location error between its actual and estimated locations. We evaluate our algorithm through extensive simulations under a variety of node densities and anchor placement methods.

Phylogenetic Relationships Using ITS2 Sequence and RAPD-PCR Data from Four Species of Korean Pseudo-nitzschia (Bacillariophyceae) (ITS2 부위의 염기서열 및 RAPC-PCR에 의한 Pseudo-nitzschia 4종의 유연관계)

  • Cho, Eun-Seob;Lee, Young-Sik
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.32-37
    • /
    • 2004
  • A portion of ribosomal internal transcribed spacer (ITS) 2 was sequenced from the samples of Pseudo nitzschia (P. deticatissima, P. multiseries, P. pungens and P. subfraudulenta) to investigate the genetic characteristics by measuring tile magnitude of genetic diversity and the degree of similarity coefficient using random amplified polymorphic DNAs (RAPD)-PCR patterns. The phylogenetic trees inferred from the genetic distance analyses showed the placement of P. delicatissima formed a quite long distance from p. P. multiseries, P. pungens, and even P. subfraudulenta. The phylogenetic tree from RAPD patterns showed that P. multiseries and P. pungens had dissimilarity coefficient of 0.31, while P. delicatissima and three species of Pseudo-nitzschia had that of 0.81. It is likely thought that the genetic position of P. delicatissima formed far from P. multiseries, P. punges, and P. subfraudulenta. These results imply that ITS2 region is expected to support a useful molecular characters for recognizing at the species level and for even discriminating P. multiseries from P. pungens. RAPD method also will be used to differentiate the species of Pseudo-nitzschia in a short time.