• Title/Summary/Keyword: Pipette

Search Result 99, Processing Time 0.023 seconds

Development of Polymer Micro-actuator using Segmented Polyurethanes and its Application for the Micro-fluidics (세그먼트화 폴리우레탄을 이용한 고분자 마이크로 액츄에이터의 개발 및 마이크로 플루이딕스에의 적용)

  • 정영대;박한수;조남주;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.285-290
    • /
    • 2004
  • Electro-active polymer, one of smart materials, is a new alternative technology, which can get an ultra precision movements and bio-compatibilty. This paper presents the relationship between elastic modulus and maximum deflection as a key property of maxwell stress effects and also presents the relationship between dielectric constant and maximum deflection as a key property of electro-striction effects in disc-type actuators using segmented PU. To induce equation about distributed load of a disc, we use boundary condition of fully clamped circular plate and to obtain design parameters of a micro-fluidics system, CFD simulation is performed.

  • PDF

The Electric Control Method on the Packaging Technology for Non-Conductive Materials Using the Surface Processing Cavity Pressure Sensor (표면 가공형 캐비티 압력센서를 이용하여 비전도성 물질용 패키지 기술에 전기적 제어방식 연구)

  • Lee, Sun-Jong;Woo, Jong-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.350-354
    • /
    • 2020
  • In this study, a pressure sensor for each displacement was fabricated based on the silicon-based pressure sensor obtained through simulation results. Wires were bonded to the pressure sensor, and a piezoresistive pressure sensor was inserted into the printed circuit board (PCB) base by directly connecting a micro-electro-mechanical system (MEMS) sensor and a readout integrated circuit (ROIC) for signal processing. In addition, to prevent exposure, a non-conductive liquid silicone was injected into the sensor and the entire ROIC using a pipette. The packaging proceeded to block from the outside. Performing such packaging, comparing simple contact with strong contact, and confirming that the measured pulse wavelength appears accurately.

A Scanning Flow Impedance Micrscope (유체역학 현상을 이용한 현미경 검사법 개발)

  • Kim, Tae-Young;Kim, Dong-Kwon;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2670-2675
    • /
    • 2008
  • We introduce a new type of surface microscope using hydrodynamic phenomena. The fluid flow through the opening of the pipette probe is blocked at short distances between the probe and the surface, thus increasing the pressure loss. Therefore, a scanning flow impedance microscope (SFIM) can image the surface topology by scanning the probe with measuring the pressure loss. The SFIM can display the topology regardless of surface hardness, surface electrical conductivity, and surrounding fluid. The present letter contains the first experimental results on surface topography obtained with this novel microscope. The preliminary results in air demonstrate the lateral resolution of the SFIM is very close to the inner diameter of the probe.

  • PDF

Consideration on Domestic Production of Materials and Consumables for Human IVF-ET Program (체외수정 및 배아이식술 관련 재료 및 소모품의 국산화 필요성에 대한 고찰)

  • Cha, Byung-Hun;Jun, Jin-Hyun
    • Development and Reproduction
    • /
    • v.15 no.4
    • /
    • pp.385-391
    • /
    • 2011
  • Human in vitro fertilization and embryo transfer (IVF-ET) program is a general procedure for infertile couples since first successful delivery on 1978 in UK and Korean first on 1985. Recently in Korea, more than 42,000 cases per year of IVF-ET were performed and showed good pregnancy rates compared worldwide data. The human IVF-ET procedure use many consumables, such as ovum pick-up (OPU) needles, centrifuge tubes, culture dish, ICSI pipette, culture media and ET catheters. Major of these materials are supported by the global companies. Thus, Korean IVF-ET program might be placed unstable situation by global economical risks. These uncertain problems could be overcome by the domestic production of IVF-ET materials and consumables. Two times questionnaires for Korean clinicians and researchers about the domestic production were performed and analyzed. Many of them requested domestic OPU needles, ET catheters, culture media and ICSI pipettes under good quality control and quality assurance system. This trial may be contributed to industrialization and to global competence of Korean IVF-ET program. The results of this survey can be provide a fundamental base for development and production of domestic materials and consumables for human IVF-ET program.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

On Board Comparison of Total Hydrogen Ion Concentration (pH) and Total Alkalinity Measurements in Seawater (해수의 총수소이온농도(pH)와 총알칼리도 측정방법에 대한 선상 비교 연구)

  • Kang, Dong-Jin;Tishchenko, Pavel Ya;Kahng, Sung-Hyun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.205-211
    • /
    • 2011
  • On board comparison of pH and total alkalinity measurement in seawater was carried out during the JES expedition on R/V Roger Revelle in the East Sea using 550 real seawater samples from the surface to the bottom. Spectrophotometry and potentiometry without liquid junction were compared for pH measurement. The pH values of two methods are generally in a good agreement. Spectrophotometry with a pipette provides higher value compare with the potentiometry in the deep layer, where pH values are lower. However, spectrophotometry without a pipette shows same values with potentiometry within their precision range. The pipetting procedure may remove of $CO_2$ in the sample, which causes increase of pH. Potentiometric titration methods using a closed-cell and an open-cell were compared for the total alkalinity measurement. Values from open cell method are smaller by about 5~10 ${\mu}mol\;kg^{-1}$ than those from closed cell method. This may be caused by the bubble formed in the closed cell during the experiment. Although any analytical method compared in this study for the pH or TA measurement can be applied, special attentions should be paid for satisfactory results.

Effect of Phorbol ester on $K^+$channel in an G292 osteoblast-like cell (G292 세포에서 $K^+$통로에 대한 phorbol ester의 효과)

  • Kim, Mi-Kyung;Park, Su-Byung
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.227-234
    • /
    • 2002
  • In order to investigate the action mechanism of protein kinase C on $K^+$ channel in osteoblastic cell, effects of phorbol 12, 13-dibutyrate on human osteoblast-like cells (G292) were studied by patch clamp technique with cell-attacked configuration. 111 this experiment, 45pS ion channel was dominant in G292 cell line according to their approximate conductances in symmetrical 140mM KCl saline at holding potential of 60mV. In torrent-voltage relationship, reversal potential was 5.5mV at the condition of potassium enriched saline in the pipette and -27 mV at the condition of standard extracellular saline In the pipette. Phorbol 12, 13-dibutyrate 10nM increased the open probability of 45pS channel and staurosporine, an inhibitor of protein kinase C, suppressed this effect. Phorbol 12,13-dibutyrate moved the reversal potential of 45pS channel to more negative potential and increased the single channel current at the same membrame potential. In order to check the activation of protein kinase C in G292 cell by phorbol 12,13-dibutyrate, western blot of protein kinase C was performed. Phorbol 12,13-dibutyrate $0.1{\mu}M$ translocated protein kinase C from cellular compartment to membrane compartment of the cell. These findings suggest that phorbol 12,13-dibutyrate, one of phorbol esters, activate 45pS channel In G292 cell and affect cell membrane potential, that regulate cellular function.

Modified CTAB DNA Methods for efficient DNA extraction from Rice (Oryza sativa L.) (벼 분자육종을 위한 CTAB DNA 추출 시스템 개량)

  • Lee, Jong-Hee;Kwak, Do-Yeon;Yeo, Un-Sang;Kim, Choon-Song;Jeon, Myeong-Gi;Kang, Jong-Rae;Park, Dong-Soo;Shin, Mun-Sik;Oh, Byeong-Geun;Hwang, Hung-goo
    • Korean Journal of Breeding Science
    • /
    • v.40 no.3
    • /
    • pp.286-290
    • /
    • 2008
  • Many important traits have been tagged allowing plant breeders to apply marker assisted selection (MAS) in rice. PCR itself is simple to set up, and requires little hands-on time. However, a crucial limiting step of MAS programs is the reliable and efficient extraction of DNA which can be performed on thousands of individuals. In this study, We describe a modification of the DNA extraction method, in which cetyltrimethylammonium bromide (CTAB) is used to extract DNA from leaf tissues for suitable MAS in rice. We followed the standard 2% CTAB extraction method in all the procedure. In addition we used the 1.2 ml 8-strip tube instead of 1.5 ml E-tubes to fit the 8-multichannel pipette and employ the 96 well plate to use the swing bucket centrifuge. Our modified CTAB DNA extraction method offers several advantages with respect to traditional and simple methods. 1) adult leaf samples collected in paddy field are applicable. 2) 96 leaf samples can be homogenized only one-time by using tungsten carbonate bead and 96well block. 3) semiautomatic loading method using 8-multichannel pipette from DNA extraction to electrophoresis of PCR products. 4) our system can extract about 400 leaf samples per day by only one technicion. Therefore, this method could be useful for marker assisted breeding in rice.

Potassium Currents in Isolated Deiters' Cells of Guinea Pig

  • Chung, Jong Woo;Nam, Eui Chol;Kim, Won Tae;Youm, Jae Boum;Leem, Chae Hun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.6
    • /
    • pp.537-546
    • /
    • 2013
  • Deiters' cells are the supporting cells in organ of Corti and are suggested to play an important role in biochemical and mechanical modulation of outer hair cells. We successfully isolated functionally different $K^+$ currents from Deiters' cells of guinea pig using whole cell patch clamp technique. With high $K^+$ pipette solution, depolarizing step pulses activated strongly outward rectifying currents which were dose-dependently blocked by clofilium, a class III anti-arrhythmic $K^+$ channel blocker. The remaining outward current was transient in time course whereas the clofilium-sensitive outward current showed slow inactivation and delayed rectification. Addition of 5 mM tetraethylammonium (TEA) further blocked the remaining current leaving a very fast inactivating transient outward current. Therefore, at least three different types of $K^+$ current were identified in Deiters' cells, such as fast activating and fast inactivating current, fast activating slow inactivating current, and very fast inactivating transient outward current. Physiological role of them needs to be established.

PREGNANCY IN CATTLE AFTER TRANSFER OF BISECTED BLASTOCYSTS OBTAINED FROM IN-VITRO FERTILIZATION OF OOCYTES MATURED IN-VITRO

  • Goto, K.;Kajihara, Y.;Koba, M.;Nakanishi, Y.;Ogawa, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.1 no.3
    • /
    • pp.153-156
    • /
    • 1988
  • Bovine blastocysts were obtained by in-vitro culture of embryos derived from in-vitro fertilization of oocytes matured in-vitro. These blastocysts and blastocysts from inseminated donors were bisected by a simple method (without a holding pipette) using a microblade operated by a micromanipulator. A pair of demi-embryos was transferred nonsurgically into each uterine horn of a recipient cow 6 or 8 days after estrus. Pregnancy resulted from the third transfer. Ultrasound examination done 52 days after estrus (46 days after transfer) confirmed the presence of at least one fetus in the each uterine horn. This is the first report to show the viability of bisected bovine blastocysts obtained from in-vitro culture of embryos derived from in-vitro fertilization of oocytes matured in-vitro. In addition, a simple method to bisect bovine embryos is described.