• 제목/요약/키워드: Pipe Size Design

검색결과 126건 처리시간 0.024초

직경이 작은 원자력배관의 파단전누설 해석에 미치는 노즐의 영향 (Effect of Nozzle on LBB Evaluation for Small Diameter Nuclear Piping)

  • 유영준;김영진
    • 대한기계학회논문집A
    • /
    • 제20권6호
    • /
    • pp.1872-1881
    • /
    • 1996
  • LBB(Leak-Before-Break) analysis is performed for the highest stress location of each different type of mateerials in the nuclear piping line. In most cases, the highest stress occurs in the pipe and nozzle interface location. i.e. terminal end. The current finite element analysis approach utilizes the symmetry condition both for locations near the nozzle and for locationa away from the nozzle to minimize the size of the finite element model and to make analysis simple when calculating the J-integral values at the crack tip. In other words, the nozzle is not included in the finite element model. However, in reality, the symmetric condition is not applicable for the pipe-nozzle interface location. Because the pipe-nozzle interface location is asymmetric due to different stiffenss of the pipe and nozzle(both material and dimensions). The simplified analysis approach for pipe-nozzle interface locaiton is too conservative for a smaller diameter piping. In tlhis paper, various analyses are performed for the range of materials and crack sizes to evaluate the nozzle effect for a LBB anlaysis. This paper presents methodology for developing the piping evaluaiton diagram at the pipe-nozzle interface location.

온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석 (Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design)

  • 신현호;남상운
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.204-211
    • /
    • 2019
  • 본 연구는 국내 온실의 환경설계 기준 설정에 필요한 기초자료 제공을 목적으로 온수난방 방식을 채택하고 있는 상업용 온실 2곳에서 난방 중 열환경 계측 실험을 실시하고, 온수난방 배관의 열전달 특성을 분석하여 난방배관의 단위길이 당 방열량 자료를 제시하였다. 실험 기간동안 두 온실의 평균기온은 각각 $16.3^{\circ}C$$14.6^{\circ}C$로 조절되었으며, 난방배관의 온수 온도는 평균 $52.3^{\circ}C$$45.0^{\circ}C$로 관측되었다. 실험결과 난방배관 표면의 자연대류열전달계수는 $5.71{\sim}7.49W/m^2^{\circ}C$의 범위로 분석되었다. 난방배관 내의 유속이 0.5m/s 이상일 때에는 관내의 수온과 관 외부의 표면온도 차이가 크지 않은 것으로 나타났다. 이를 바탕으로 난방배관의 관류열전달계수를 수평원통에서의 층류 자연대류열전달계수의 형태로 유도하였다. 유도된 관류열전달계수 식을 변형하여 관의 규격과 온수-실내공기의 온도차를 입력 변수로 하는 난방배관의 단위길이 당 방열량 산정식을 개발하였다. 본 연구 결과를 기존에 제공되고 있는 국내외 여러 자료와 비교한 결과 JGHA 자료와 가장 유사한 것으로 나타났다. 국내 온실의 설계에서 적용하고 있는 NAAS 자료와 국외의 BALLS 및 ASHRAE 자료는 값이 너무 큰 것으로 판단된다. 따라서 국내 온실의 환경설계기준을 제정하고, 고시하기 위해서는 추가적인 실험을 통해 이 부분에 대한 충분한 검토가 필요할 것으로 판단된다.

박막 공정을 이용한 초소형 내시경의 MicroWiring System의 개발 (The Development of Micro Wiring System for Micro Active Endoscope)

  • 정석;장준근;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1997
  • In the field of Micro-Mechanics, it has been known diffcult to integrate the micro-machine with sensor and source line for the conventional copper line cnanot be used in compact and small size. We developed a system to make thethin copper film as a connect line on the poyurethane pipe (2mm in diameter) by the evaporation technique. This system consists of an evaporation chamber two long branches, substrate hoider and a Linear-Rotary motion feed feedthrough. The results showed that thin copper film coated polyurethanc pipe could be applied th the small medical devices such as the micro active endoscope.

  • PDF

히트 파이프가 장착된 정지궤도 위성 패널 열해석 프로그램 개발 (DEVELOPMENT OF THERMAL ANALYSIS PROGRAM FOR HEAT PIPE INSTALLED PANEL OF GEOSTATIONARY SATELLITE)

  • 전형열;기정훈;한조영;채종원
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.416-421
    • /
    • 2010
  • The north and south panel of a geostationary satellite are used for radiator panels to reject internal heat dissipation of electronics units and utilize several heat pipe networks to control the temperatures of units and the satellite within proper ranges. The design of these panels is very important and essential at the conceptual design and preliminary design stage so several thousands of nodes of more are utilized in order to perform thermal analysis of panel. Generating a large number of nodes(meshes) of the panel takes time and is tedious work because the mesh can be easily changed and updated by locations of units and heat pipes. Also the detailed panel model can not be integrated into spacecraft thermal model due to its node size and limitation of commercial satellite thermal analysis program. Thus development of a program was required in order to generate detailed panel model, to perform thermal analysis and to make a reduced panel model for the integration to the satellite thermal model. This paper describes the development and the verification of panel thermal analysis program with ist main modules and its main functions.

  • PDF

해저터널용 복합신소재 배수복합관 부재의 정적거동에 관한 실험적 연구 (An experimental study on the static behavior of advanced composite materials drainage pipe member for an undersea tunnel)

  • 신종호;김강현;김두래;지효선
    • 한국터널지하공간학회 논문집
    • /
    • 제17권2호
    • /
    • pp.65-74
    • /
    • 2015
  • 해저터널용 복합신소재 배수관구조를 설계하기 위해서는 복합신소재 구조부재의 적층형태별 역학적 성질을 결정하는 것이 필수적이다. 복합신소재는 일반적으로 등방성 재료와 달리 치수효과가 매우 큰 것으로 알려져 있다. 본 연구에서는 복합신소재 부재의 적층형태별 인장시험을 상온($20^{\circ}C$)과 해수온도($0^{\circ}C$)에서 각각 수행하였다. 또한, 이론적 해석방법인 혼합물의 법칙과 탄성해법을 적용하여 재료의 역학적 성질을 추정하고 시험결과와 비교를 하였다. 해저터널 복합신소재 배수관 구조부재를 설계할 때 사용되는 역학적 성질의 값은 상온에서 얻어진 값을 보정하여 적용하여야 된다. 이러한 자료는 향후 해저터널용 복합신소재 배수관구조의 설계의 기초자료로 제공하고자 하였다.

Seismic Fragility of Steel Piping System Based on Pipe Size, Coupling Type, and Wall Thickness

  • Ju, Bu Seog;Gupta, Abhinav;Ryu, Yonghee
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1200-1209
    • /
    • 2018
  • In this study, a probabilistic framework of the damage assessment of pipelines subjected to extreme hazard scenario was developed to mitigate the risk and enhance design reliability. Nonlinear 3D finite element models of T-joint systems were developed based on experimental tests with respect to leakage detection of black iron piping systems, and a damage assessment analysis of the vulnerability of their components according to nominal pipe size, coupling type, and wall thickness under seismic wave propagations was performed. The analysis results showed the 2-inch schedule 40 threaded T-joint system to be more fragile than the others with respect to the nominal pipe sizes. As for the coupling types, the data indicated that the probability of failure of the threaded T-joint coupling was significantly higher than that of the grooved type. Finally, the seismic capacity of the schedule 40 wall thickness was weaker than that of schedule 10 in the 4-inch grooved coupling, due to the difference in the prohibition of energy dissipation. Therefore, this assessment can contribute to the damage detection and financial losses due to failure of the joint piping system in a liquid pipeline, prior to the decision-making.

쓰레기 관로운송 시스템의 운송에너지 손실에 관한 수치해석적 연구 (Computational Study of Energy Loss in a Pipe of Refuse Collecting System)

  • 이종길;변재기;최영돈;최윤;홍기철
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes energy loss in a pipe line of refuse collecting system. Analysis of energy loss in a pipe line is the decisive factor in a design of refuse collecting system. Using the results of energy loss analysis, we can determine the power of turbo-blower. The flow characteristics of the pipe line with refuse bags were analyzed by three-dimensional CFD. The refuse bag is modeled by using the shape obtained from profile measurement. Friction factors were calculated with changing the refuse bag size, mixing ratio and Reynolds number. And drag coefficients were calculated using the CFD results. From the results we can calculate energy loss in a pipe line of refuse collecting system and predict the capacity of turbo-blower.

고세장비 미세채널 기반의 마이크로 히트파이프 설계 및 제조 (Design and Fabrication of a Micro-Heat Pipe with High-Aspect-Ratio Microchannels)

  • 오광환;이민규;정성호
    • 한국정밀공학회지
    • /
    • 제23권9호
    • /
    • pp.164-173
    • /
    • 2006
  • The cooling capacity of a micro-heat pipe is mainly governed by the magnitude of capillary pressure induced in the wick structure. For microchannel wicks, a higher capillary pressure is achievable for narrower and deeper channels. In this study, a metallic micro-heat pipe adopting high-aspect-ratio microchannel wicks is fabricated. Micromachining of high-aspect-ratio microchannels is done using the laser-induced wet etching technique in which a focused laser beam irradiates the workpiece placed in a liquid etchant along a desired channel pattern. Because of the direct writing characteristic of the laser-induced wet etching method, no mask is necessary and the fabrication procedure is relatively simple. Deep microchannels of an aspect ratio close to 10 can be readily fabricated with little heat damage of the workpiece. The laser-induced wet etching process for the fabrication of high-aspect-ratio microchannels in 0.5mm thick stainless steel foil is presented in detail. The shape and size variations of microchannels with respect to the process variables, such as laser power, scanning speed, number of scans, and etchant concentration are closely examined. Also, the fabrication of a flat micro-heat pipe based on the high-aspect-ratio microchannels is demonstrated.

연소효율 향상을 위한 공기-미분탄 수송배관장치의 최적화 설계 프로그램 개발 (Development of Optimal Design Program of Air-Coal Pneumatic Conveying System to Enhance Combustion Efficiency)

  • 구재현
    • 한국가스학회지
    • /
    • 제13권5호
    • /
    • pp.7-14
    • /
    • 2009
  • 본 연구는 석탄화력발전소 노의 연소효율 향상을 위하여 미분탄 수송배관의 공기-입자 유동장의 압력손실 특성을 분석하여 미분탄 수송장치 내에 설치되어 유량을 제어하는 오리피스의 설계에 적용하고자 하는 것이다. 통상의 미분탄 수송배관장치는 관의 형태에 따라 직선관, 곡선관 및 엘보우로 구성된다. 본 연구에서는 공기유동과 입자운동의 상호작용 해석을 통하여 직선관과 곡선관을 갖는 미분탄 수송배관장치 내의 압력손실을 분석하였다. 총 압력손실은 공기-미분탄 입자의 마찰 손실 증가와 배관의 길이, 곡선관 각도의 증가에 따라 증가하는 것으로 확인되었다. 연구결과로 압력손실과 유량제어를 위한 최적화된 오리피스 설계 프로그램이 개발되었으며 그 계산 결과를 기존의 실험결과와 비교, 분석하였다.

  • PDF

Siphon을 이용한 Cherepnov 送水機의 揚程 決定 (A Determination of Discharge Head of the Cherepnov Water Lifter with Siphon)

  • 이관수;이경훈
    • 물과 미래
    • /
    • 제29권1호
    • /
    • pp.213-220
    • /
    • 1996
  • 본 연구는 siphon의 수리학적 현상을 이용하여 배수를 제어하는 Cherepnov 송수기의 효율적인 양정(유입수조의 수면과 송수관 출구의 위치차)을 결정하기 위한 실험적 연구이다. 본 송수기는 물 자체가 가지고 있는 위치에너지에 의하여 작동되어지며, 송수기의 구조는 상단 개구부를 갖는 1개의 수조와 밀폐된 2개의 수조, 5개의 관 그리고 2개의 역지변이 상호 연결되어 있다. 양정과 낙하고 비(H$$/H$$)의 변화에 대한 본 송수기의 수리학적 거동과 작동특성을 조사 연구하기 위하여 각 수조내의 수위와 압력변화를 측정하였으며, 송수기의 수조와 연결관의 직경이 송수기의 양정과 낙하고 비(H$$/H$$)에 미치는 영향을 분석하였다. 본 실험에 의하여 송수기의 효율을 높일 수 있는 효율적인 양정은 낙하고의 약 1/2배 정도이었다. 따라서 효율적인 Cherepnov 송수기를 제작하기 위하여는 낙하고를 양정의 2배정도로 설계해야 할 것으로 판단된다. 수조크기가 효율에 미치는 영향은 5% 이하인 반면 관의 크기가 효율에 미치는 영향은 관크기에 따라 증가되었다.

  • PDF