• Title/Summary/Keyword: Pipe Installation

Search Result 264, Processing Time 0.028 seconds

A Case Study on Cold Water Damage to Rice by Installation of Underground Drain Pipe at a Mountainous Valley (산간 계곡의 지하배수관 설치에 따른 벼 냉수피해 사례분석)

  • Shim, Kyo-Moon;Jung, Myung-Pyo;Kim, Yong-Seok;Choi, In-Tae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.270-274
    • /
    • 2015
  • The complaint was filed for the cold water damage to rice in accordance with the installation of buried drain pipes in the mountainous areas of the valley. Field research was conducted in order to identify and analyze relevance of cold water damage to rice with underground drain pipe installation. In conclusion, water temperature was analyzed by 0.5 to $4.5^{\circ}C$ lower than before the installation of underground drain pipes, so the cold water damage to rice was likely to occur at the rice paddy field using cold water passing through the underground drain pipe. Therefore, the rice harvest was estimated to be impossible without appropriate measures of water temperature rise such as use of small unshaded warming basins, before water is applied to fields.

A Study for the Corrosion Property of Sprinkler Pipe and the Solution (스프링클러 배관의 부식 특성과 대책에 관한 연구)

  • Kim, Dong-Sung;Cho, Won-Cheol;Kim, Byung-Seon;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.461-464
    • /
    • 2008
  • This study is for the corrosion property of sprinkler pipe and the prevention solution. The main causes of corrosion are the deterioration of pipe and wrong installation of pipe. This study includes the property of stainless pipe that is widely used as sprinkler pipe and other kinds of pipe, the theory of corrosion procedure and the result of test that is performed to ascertain the advance degree of corrosion about "A" factory complex using pipe samples that were collected at designated point of each factory complex.

  • PDF

Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device (아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구)

  • Yum, Kyung-Taek;Choi, Jung-Wook;Yang, Sung-Bong;Shim, Hak-Sup;Yu, Mee-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.465-476
    • /
    • 2021
  • Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of ㎍/L, and in the case of discharging ground or tap water, it was verified to be tens of ㎍/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.

Establishment of Information Interface Technology between Hull and Outfitting Designs (선체설계와 의장설계간의 정보인터페이스 기법 연구)

  • Choi, Yeong-Tae;Suh, Heung-Won;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.6
    • /
    • pp.458-465
    • /
    • 2013
  • Ship design engineering refers to the development and design of shipbuilding architectures in a drawing which reflects all relevant manufacturing processes. This paper provides analysis methods for model-information interfaces between hull structure design and outfitting design, and a technical application for manufacturing phases reflecting the pipe support pad and angle item automatically. The existing information procedure of pipe support pad and angle system processes information using drawing without model specification. Outfitting design team directly distributes drawings to the shop floor then manual-based marking and installation work are conducted refer to the distributed drawings. As a result, this process has become time consuming and causes problems in the productivity and quality improvement due to the rework caused by omitted or incorrect marking. The pipe support pad and angle marking is a method that automatically updates model information to hull structure design using sets of data that analyse the generated model in outfitting design processes. Therefore, this approach provides an efficient solution through design references without manual activities such as a reflection of hull structure design, cutting process, numerical control work, and dimension measurement and marking. The conversion of a method from the existing procedure based on manual marking to the reflective and automatic approach would have enabled to proceed installation work without manual activities for the measurement. Therefore, this research study proposes an efficient approach using pre-data analysis of model information interfaces between design and manufacturing phases to improve productivity during construction for shipbuilding.

Development of an Anti-Freezing Heating Cable Temperature Controller and Its Power Saving Effects Analysis (동파방지 발열선용 온도제어기 개발 및 전기에너지 절감 효과 분석)

  • Lee, Kihong;Lee, Jaejin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.101-106
    • /
    • 2014
  • Although anti-freezing heating cable has been widely installed in most residential boiler pipe, there were excessive energy consumption and fire risk due to inadequate temperature control. In this paper, a new energy saving fire risk-free controller was developed by using microprocessing operation which include detection of not only boiler room temperature but also pipe surface one. Its actual effect has been verified to save more than a half of the energy consumption comparing to conventional controller through temperature and humidity chamber experiment.

Development of Outdoor 50W-LED Module using Heat-pipe and Stack-fin (히트파이프 및 스택핀을 이용한 50W급 옥외용 LED 모듈개발)

  • Hong, Seok-Gi;Jeong, Hee-Suk;Ryeom, Jeong-duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.15-21
    • /
    • 2015
  • We proposed 50W-LED modules of using Heat-pipe and Stack-fin and produced LED modules was evaluated heat dissipation characteristics with comparison of the conventional die-casting type. It verified the application of products by applying it to 150W-LED road luminaires through simulation. The LED module was measures aimed design temperature of the Stack-fin and showed 26% upward heat dissipation effect than a conventional die-casting type. The luminous efficacy of 150W-LED road luminaires using this LED module reached over 112lm/W, and the simulation results showed average of horizontal luminance, overall luminance uniformity($U_O$) and lane luminance uniformity($U_I$) that is suitable for five-lane road with the KS standards.

An Application of Overlap Avoidance to Augment the Production Data in Pipe Installation Drawings (배관설치도 내 생산정보 증강을 위한 겹침 회피 알고리즘의 적용)

  • Hwang, InHyuck;Ruy, WonSun;Park, InHa;Park, JungSeo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.5
    • /
    • pp.428-434
    • /
    • 2016
  • A lot of drawings for pipe construction and installation are needed to construct plant process system on the offshore plant structures. Depending on their scale or complexity, the required number of drawings related pipes sometimes amounts to several hundreds of thousands. Most major shipyards, therefore, have their own system which can automatically depict pipes’ geometric, manufacturing, and BOM(Bill of Material) information on the drawings. However, as the complexity and absolute quantity in the isometric region on the drawings is increased, the information extraction from the customized DB and positioning at the typical locations does not get to be enough to avoid the overlap between geometric contours, labels, and symbols. For this reason, the novel methods to arrange additional annotations without overlaps are presented in the paper. This approach is expected to increase the readability and legibility of the drawing and prevent the human error, and finally decrease the time-consuming and tedious jobs which are unnecessarily required to designers.

Optimal Pipe Replacement Analysis with a New Pipe Break Prediction Model (새로운 파괴예측 모델을 이용한 상수도 관의 최적 교체)

  • Park, Suwan;Loganathan, G.V.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.16 no.6
    • /
    • pp.710-716
    • /
    • 2002
  • A General Pipe Break Prediction Model that incorporates linear and exponential models in its form is developed. The model is capable of fitting pipe break trends that have linear, exponential or in between of linear and exponential trend by using a weighting factor. The weighting factor is adjusted to obtain a best model that minimizes the sum of squared errors of the model. The model essentially plots a best curve (or a line) passing through "cumulative number of pipe breaks" versus "break times since installation of a pipe" data points. Therefore, it prevents over-predicting future number of pipe breaks compared to the conventional exponential model. The optimal replacement time equation is derived by using the Threshold Break Rate equation by Loganathan et al. (2002).

Development of Automatic Pipe ISO-Drawing and BOM Generation System (배관 제작, 설치 ISO 도면 및 BOM 정보 자동 생성 시스템 개발)

  • Woo IlGuk;Kim ShinHyung;Heo CheoIEun;Cho YongNam;Gu JaMin;Kim Daejin
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.127-133
    • /
    • 2005
  • DSME has successfully developed the unified CAD system (DACOS) for the commercial ship based on its design know-how accumulated for several years. Currently, DSME is expanding the unified CAD system to plant and special ship design. In this paper, the development of pipe design, especially, isometric drawing and BOM(Bill of Material) generation will be introduced isometric drawing and BOM generation are major activities of pipe design in shipbuilding. The drawing is used for pipe construction and installation while the BOM is used for purchasing and manufacturing pipe line. These activities are time-consuming and tedious jobs done by designers because the drawing should be generated as a non-scaled symbolized drawing that can be easily understood and the BOM information should be extracted without mistake. Therefore, we implemented automatic isometric drawing and 80M generation system for pipe design. In this paper, the developed system and the used technology will as well be introduced and a design output in a plant project as an applied example will be illustrated.

  • PDF

Research for KGS FS551 Amendment Using Abroad Code and Structure Simulation (해외규격과 구조해석을 이용한 KGS FS551 개정안 연구)

  • Kang, Byung-Ik;Kim, Byung-Gi;Kim, Byung-Duk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.7-16
    • /
    • 2019
  • According to KGS FS551, the safety of an exposure pipe system should be calculated quantitatively by calculating the stress of exposed piping for thermal expansion. However, many pipe system designs and installation sites are not equipped for this. Therefore, KGS FS551 suggested the use of safe gas by presenting the recommended pipe shape. The shapes of various pipe systems have been derived. However, the recommended shape could not be an absolute evaluation standard. Furthermore, the ongoing debate over standards between a plumbing installer and an inspector is an obstacle to the efficient and safe use of gas. Therefore, the correct pipe system evaluation method is examined in this study, and the safety of the existing exposed pipe system is verified.