• Title/Summary/Keyword: Pipe Connection

Search Result 122, Processing Time 0.027 seconds

배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석 (Analysis of hydraulic system for seawater desalination plant through piping analysis program)

  • 최지혁;최용준;양흥식;이상호;최준석
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

강관 말뚝 기초 두부 연결부의 합성거동에 대한 연구 (The Study on Local Composite Behavior of Connection Member between Steel Pipe Pile and Concrete Footing)

  • 유성근;박종면;박대용;김영호;강원호
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.288-296
    • /
    • 2003
  • 최근 말뚝기초 공법으로서 강관말뚝의 활용이 토목 및 건축 분야에서 증대됨에 따라 이종의 재질을 가진 강관 말뚝과 콘크리트 확대 기초의 연결방법에 대한 기술개발 및 실제거동 파악에 대한 관심이 매우 높아지고 있다. 연결부에 대한 국내 시방서는 두 가지(A, B-type) 연결방법을 제시하고 있지만 실제적으로는 B-type 방법이 주로 활용되고 있는 상황이다. 본 논문에서는 강관 말뚝의 B-type 연결방법의 구조거동을 파악하기 위하여 말뚝에 작용하는 대표적인 하중인 연직하중에 대하여 3종류와 수평 하중에 대하여 두 종류의 실험체에 대한 재하시험을 실시하였다. 또한 재하실험 결과값에 대한 비교 분석을 위하여 3차원 유한 요소해석을 수행하였다. 실험과 수치해석 결과를 비교 분석한 바 현재 강관 말뚝 연결부의 설계법으로 적용되고 있는 가상 철근 콘크리트 기둥의 거동을 확인하였다. 또한 콘크리트 확대기초에 작용하는 하중을 강관으로 전달하기 위하여 사용되는 미끌림 방지턱의 역할과 이러한 방지턱이 강관과 콘크리트의 합성거동에 미치는 영향을 확인하였다. 본 연구를 통하여 향후 합리적인 강관 말뚝 연결부에 대한 설계 방법 및 기준을 정립함에 있어 기초 연구자료와 강관 말뚝 연결부의 구조거동을 파악하기 위한 실험방법을 제시하였다.

표준품셈 관부설 및 접합공사 품 개정 요인 분석 (Analysis on the Factor of Revision of Pipe Laying Down Material and Connection Work Material)

  • 오재훈;안방율
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.302-303
    • /
    • 2018
  • This study analyzed the major revision factors and revision contents for 'Construction-Standard-Production-Rate for Construction Works in 2018. Part 16. Pipe Laying Down and Connection" which was revised by the construction expense estimation standard's middle and long-term plans. The main reasons for the revision was analyzed to be unclear construction scope, limitations in applicable pipe material based on the facility type, labor force mainly composed of ordinary workers, limitations of labor force, and incomplete appropriation standard for the tool rent fee and equipment expenses. Through revision of factors, common items were newly established, organization was revised, the labor force was mainly composed of the technicians, and basis for appropriation of equipment expenses was arranged. In addition, through periodic revision, the appropriation standard for bend and special pipes was set. Consequently, more practical construction cost estimate standard is arranged through revision.

  • PDF

CSJ 개발을 위한 캐리어 파이프의 변형해석 (Deformation Analysis of Carrier Pipe for Cold Shrinkable Joint)

  • 이양창;이준성;이호정;류정현
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.314-319
    • /
    • 2010
  • 본 논문은 초고압 전력케이블의 접속재 개발을 위한 연구결과로써, 접속시스템의 핵심기술인 고절연 고무슬리브의 현장 접속 작업의 용이성을 위한 Carrier Pipe의 구조해석과 주요부의 전기적 특성과 전계의 집중을 완화하기 위한 수치해석 등을 실시하여 구조적 안정성을 평가하려 한다. 절연설계 및 전계완화 해석에 의한 검증과 접속재의 수축거동 해석에 의한 Carrier Pipe의 최적화된 형상으로 두께가 최소 9mm이상을 갖는 Carrier Pipe가 필요하며, 전기적 전계완화 해석결과 고절연 고무슬리브의 중앙매립전극 경계면으로써, 접속재 수축거동 해석 결과와도 일치함을 검증할 수 있었다.

Integrated Expansion Analysis of Pipe-In-Pipe Systems

  • 최한석
    • 한국해양공학회지
    • /
    • 제20권5호
    • /
    • pp.9-14
    • /
    • 2006
  • This paper presents an analytical method, application of expansion, mechanical design, and integrated expansion design of subsea insulated pipe-in-pipe (PIP) systems. PIP system consists of a flowline and a casing pipe for the transport of high temperature and high pressure product from the subsea wells. To prevent heat lass from the fiowline, insulation material is applied between the pipes. The fiawline pipe and the casing pipe have mechanical connections through steel ring plate (water stops) and bulkheads. Pipeline expansion is defined by temperature, internal pressure, soil resistance, and interaction force between the flowline and the casing pipe. The results of the expansion analysis, the mechanical design of connection system of the two pipes and tie-in spool design are integrated for the whole PIP system.

비상시 용수공급을 위한 상수도 연계관로의 수리적 적정성 평가 (Hydraulic Adequacy of Connection Pipes in Water Supply Systems for Contingencies)

  • 한완섭;정관수;김주환
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.679-687
    • /
    • 2013
  • Although stable and safe drinking water supply to the customers is a basic function of multi-regional water supply systems in Korea, most systems have their vulnerabilities in emergency time due to the branch-type. Application of connections from the other water supply system can provide a solutions for these tentative problems. This paper describes reduction planning of water supply accidents that can minimize a service interruption to customers in multi-regional water supply system by connecting pipe lines between local water supply systems in Mokpo city areas. The result of this study shows that Juam dam multi-regional water supply systems can cover all of the water shortage in southern parts of Jeonnam multi-regional water supply systems by transmitting water through connected pipes between local networks. This can be effective to supply water interactively in various contingencies, when a pipe line accident occurs in southern area of Jeonnam multi-regional water supply systems. On the contrary, southern area of Jeonnam multi-regional water supply systems can cover 99.5 %($62,500m^3/day$) of the water shortage of Juam dam multi-regional water supply systems when service interruptions caused by various pipe accidents occur in the system.

원자로냉각재계통 3" 분기관 용접부 위상배열초음파탐상검사(PAUT)기법 개발 (Development of the Phased Array Ultrasonic Test Technique for the Weld Inspection of Reactor Coolant System 3" Branch Connection Lines in Nuclear Power Plants)

  • 이승표;문용식;정남두;조용배;김창수
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.40-45
    • /
    • 2008
  • There exist many types of pipe and component fatigue through vibrations, thermal fatigues or shifting. In some cases of thermal stratification/thermal fatigue, pipes & components are receiving thermal stress by means of material expansion and shrinkage by continuous thermal repetitive variation. Small cracks initially occur on the inside surface by thermal stress. These cracks grow in depth the pipe wall and finally come to a rupture. Pipe parts of susceptibility to thermal stratification and thermal fatigue are now being examined by conventional UT(ultrasonic test) as volumetric examination. It is difficult to fully satisfy the code & standards requirements because 3" weldolet weldments of RCS 16" pipe to 3" branch connection lines have complex structural shape. To solve the problems of conventional UT examination, we made a realistic mock-up and UT calibration block. We performed a simulation of phased array UT utilizing CIVA as NDE(Non-Destructive Examination) simulation software. Also we designed phased array UT transducer and wedge, optimal frequency by using simulation data. We performed phased array UT experiment through mock-up including artificial flaws(notch). The phased array UT technique is finally developed to improve the reliability of ultrasonic test at RCS 16" pipe to 3" branch connection weld.

  • PDF

새로운 강관말뚝 머리 보강 공법 개발 (A New Way of Connecting Method Between Steel Pipe Pile and Concrete Footing)

  • 박영호;김낙영;박종면;유성근;김영호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.413-420
    • /
    • 2002
  • Recent experimental research results of connection method between steel pipe pile and concrete footing are provided based on various experimental observations. It gives a shedding light toward developing better and concrete connection method for steel pipe pile at the field application. In this study, the newly developed method is tested for compressive, pull put and combination load including moment with carefully designed monitoring system. The measured data show that new method have at least equivalent or better load resistant capacities compared with those of specified method in Korea Highway Corporation design code. It is also tried to define and investigate the load transfer mechanism for new method.

  • PDF

효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구 (A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities)

  • 손개성;최지훈;최돈묵
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

Type-B방식의 강관말뚝과 확대기초 연결부 상세에 따른 보유내력의 실험적 평가 (Experimental Evaluation of Reserve Capacities for Connection Details between Steel Pipe Pile and Concrete Footing of Type-B)

  • 한상훈;홍기남;권용길
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.183-192
    • /
    • 2008
  • 본 연구에서는 강관 말뚝 두부보강 방법으로 사용되고 있는 용접방법과 훅형방법의 성능평가를 위한 실험적 연구를 수행하였다. 실험은 강관 말뚝 두부 연결부에 작용하는 대표적 하중인 압축과 수평하중에 대한 정적 재하실험과 인장실험으로 구분하여 수행하였다. 압축하중은 강관말뚝이 부담하는 주된 하중이며, 수평력은 지진하중을 고려하여 설계할 때 필수적으로 검토하여야 한다. 또한, 강관 파일 두부연결부의 인장내력은 안전성 검토에 있어서 중요한 요인으로 고려되고 있다.강관 말뚝 두부보강 성능평가 실험에서 고려된 실험변수는 Table 1과 같이 두부보강방법인 훅형과 용접형을 고려하였다. Table 1에 실험체 일람을 나타내었다.