Abstract
Generally, application of steel pipe pile as deep foundation member needs special requirement for the connection method between steel pipe pile and concrete footing. Even though two types of connection method are suggested in the korea highway bridge code, type-B method is prevalent. In this study, vertical, lateral, and tension loading test are done for two types of type B connection to review stress concentration, formation and behavior of imaginary RC column in the footing. Welding type and hook type as the connection method are considered in this study. Test results show that welding type have the more reserve capacity than hook type and the specimens connected by the welding type behave as the imaginary RC column in the footing. However, the specimens connected by the hook type did not behave as the imaginary RC column in the footing but behave as the hinge.
Keywords
Hook type; Imaginary RC column; Reserve capacity; Welding type;
Citations & Related Records
연도 인용수 순위
  • Reference
1 주봉철, 김영진, 김병석, 박성용, 문근호, "U자형 절곡철근을 이용한 강관멀뚝 머리보강 방법", 대한토목학회학술발표대회, 2002. 10, pp. 18-21
2 김영호, "강관말뚝 머릿결합부의 미끄럼 방지턱에 관한 하중전달 메카니즘 연구", 한국구조물진단학회, 제8권, 1호, 2004. 1, pp. 221-229
3 유성근, 박종면, 박대용, 김영호, 강원호, "강관 말뚝 기초 두부 연결부의 합성거동에 대한 연구", 한국콘크리트학회논문집, 제15권, 2호, 2003. 4, pp. 288-296
4 한국지반공학회, "구조물기초설계기준해설", 2003
5 서울대학교 지진공학연구센터, "강관말뚝 합성형 두부보강방법의 구조 안전성 검증", 2001. 1
6 건설교통부, "도로교 설계기준", 2000