• Title/Summary/Keyword: Pin to pin

Search Result 2,318, Processing Time 0.026 seconds

Metal/ceramic Interface Mechanical Property Analysis (금속/세라믹 계면 물성 분석)

  • Kim, Song-Hee;Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.9-15
    • /
    • 2004
  • The flexural strength from 3-point bend test and fatigue properties were measured to evaluate mechanical properties of metal/ceramic interface of the multilayer ceramic package produced through tape casting. From the results, the specimens with three electrode layers showed the highest strength. The temperature distribution with time during thermal cycle and thermal stresses with the change of electrode's shape have been estimated by mathematical modelling. Specimen affected by thermal shock, produced microcracks by the difference of thermal expansion coefficient. The results of tensile test and fatigue test showed the rupture at pin. The fact that the pin brazed specimens were always fractured at the pin proved the good bonding condition between pin and electrode.

  • PDF

A study on the chucking system in coaxial grinding of ferrule (페룰 동축 연삭시 척킹 시스템에 관한 연구)

  • Kim, Dong-Kil;Lee, Sang-Jo;Ahn, Geon-Jun;Kwak, Chol-Hun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.987-991
    • /
    • 2003
  • Ferrule is widely used as fiber optic connecters. In fiber-optic communications, the shape accuracy such as coaxiality and cylindricity of ferrule affects insertion loss. When coaxial grinding of ferrule supported by two pin, pin alignment and chucking accuracy are very important. In this research, the kinematic behavior of the ferrule center is investigated in the case where cone-shaped center pins and round circle holes which make contact with each other near the edge of the holes, using homeogenous coordinate transformation and numerical analysis. The obtained results are as follows: The alignment errors between center holes cause a sinusoidal displacement of ferrule. And the maximum displacement of ferrule centers increase in proportion to the center pin angle. The relationship between center pins displacement in coaxial grinding and grinding accuracy was explained.

  • PDF

Stress Analysis of MWK Composite Laminate with Multi-pin Loaded Holes (다중 핀 하중을 받는 MWK 복합재료의 응력 해석)

  • 조민규;김병구;전흥재;변준형
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.74-78
    • /
    • 2003
  • Stress analysis was conducted with finite element method to study the stress distributions in both single-pin and multi-pin loaded composite laminates. The various parameters involved in the design of the joint method were considered. The stress distributions in the vicinity of the holes were predicted considering the effects of various parameters such as the lay-ups, number of pins, number of rows, row spacing, and hole patterns. The results show that the performance of joint is greatly affected by these parameters.

  • PDF

A Study on the Development of Electronic Personal Dosimeter with Silicon PIN Photodiode (실리콘 핀 포토다이오드를 이용한 전자 선량계의 설계 및 구현)

  • Yi, Un-Kun;Kwon, Seok-Geon;Kim, Jung-Seon;Sohn, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2285-2288
    • /
    • 2002
  • Recently, electronic personal dosimeters based upon silicon PIN photodiode or miniature GM tube were developed and have attracted a lot of attention because of the advantages of their nature such as indication of dose rate and the cumulative dose, and facilitation of record keeping. In this paper, we have developed a high-sensitivity electronic personal dosimeter with silicon PIN photodiode. The electronic personal dosimeter is constructed with silicon PIN photodiode, preamplifier, and shaping amplifier. To show the effectiveness of electronic personal dosimeter, we conducted nuclear radiation experiments using $\gamma$-ray Ba-133, Cs-137, and Co-60. The electronic personal dosimeter have a good linearity on $\gamma$-ray energy and activity.

  • PDF

Application of heterogeneous RNA probes labeled immuno-fluorescent agent DIG for the screening a noble gene in cucumber

  • Kim, Dai-Hee;Kim, Byung-Oh;Park, Gyu-Hwan;Takahashi, Hideyuki;Kim, Kyung-Min
    • Plant Resources
    • /
    • v.7 no.2
    • /
    • pp.116-122
    • /
    • 2004
  • We tried to isolating a noble gene from cucumber library with heterogeneouse RNA probe labeled DIG of Arabidopsis PIN3 gene. Two kinds of RNA probes which had no significant homology each others, were designed from the 5'- and 3'- prime nucleotides of the AtPIN3 gene. In the first and second screenings of the cDNA library of cucumber with the probes, two positive clones were identified with specific duplicate signals. However, we isolated cDNA fragments homologous with putative nucleases from Nicotiana, Arabidopsis, Cordialis, and Oryza sativa, there was no significant homology with any other PIN family genes.

  • PDF

Implementation of Popular Radon Detector Using Pin Photodiode (핀 포토다이오드를 이용한 보급형 라돈 검출기의 구현)

  • Yun, Sung-Ha;Kim, Jae-Hak;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.99-106
    • /
    • 2016
  • When radon is staying at alveoli and bronchial tubes, the collapse of radon creates progeny nuclides (alpha ray, beta ray, gamma ray, etc.). They emit radiation causing a mutation in the chromosome of the cell, resulting in lung cancer. In other words, the main cause of lung cancer is radiation emitting as the result of radon collapse rather than radon gas. The 82% of radiation exposed to people is the natural radiation. Most of the natural radiation is radon. If we properly control the concentration of radon indoors, the probability of occurrence of lung cancer could be decreases to be 70%. Until now, to measure the indoor radon concentration, imported radon sensors are needed. So, DB construction of indoor radon emission and popular radon measuring apparatus should be developed. In this paper, we propose the radon detecting method using PIN photodiode. Also, we confirmed the PIN photodiode could be used as radon sensor module through some experimental studies.

Characteristics Analysis of 2-pin Sensor Composited Fuel Heater using the Low Temperature Fluidity (저온유동성시험기를 이용한 2-핀용 센서통합연료히터의 특성연구)

  • Xiang, Zhao;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1230-1235
    • /
    • 2019
  • In this paper, we have developed sensor composited heater of 2-pin, and unified the fuel filter. In order to evaluate the performance of the 2-pin sensor composited fuel heater, we have make of the low temperature fluidity system. The one measure and analysis the electrical and oil flow quantity characteristics at an input and out port of 2-pin sensor composited fuel heater. Especially, in the characteristics verification elements of the proposed goods, we use the test chamber for the temperature variable and oil flow quantity test, and designed an embedded system for interfacing an engine. By interfacing both user and the system, it support an experimental and date gathering function in 2-pin sensor composited fuel filter. And then test the temperature, oil pressure, electrical characteristics and oil flow quantity in variable status from - 30 ℃ to + 80 ℃. These can help us to determine the quality and performance of elementary goods.

Shape Optimization of a Rotating Cooling Channel with Pin-Fins (핀휜이 부착된 회전하는 냉각유로의 최적설계)

  • Moon, Mi-Ae;Husain, Afzal;Kim, Kwang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.703-714
    • /
    • 2010
  • This paper describes the design optimization of a rotating rectangular channel with staggered arrays of pin-fins by Kriging metamodeling technique. Two non-dimensional variables, the ratio of the height to the diameter of the pin-fins and the ratio of the spacing between the pin-fins to the diameter of the pin-fins are chosen as the design variables. The objective function that is a linear combination of heat transfer and friction loss related terms with a weighting factor is selected for the optimization. To construct the Kriging model, objective function values at 20 training points generated by Latin hypercube sampling are evaluated by a three-dimensional Reynolds-averaged Navier-Stokes (RANS) analysis method with the SST turbulence model. The Kriging model predicts the objective function value that agrees well with the value calculated by the RANS analysis at the optimum point. The objective function is reduced by 11% by the optimization of the channel.

Development of Prototype Electronic Dosimeter using the Silicon PIN Diode Detector (실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.197-205
    • /
    • 2000
  • A prototype electronic dosimeter(PED) adopting a silicon PIN diode detector as a radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this PED has been performance-tested by using a reference photon radiation field. As a result in a electronic performance test, radiation signals from a detector were well observed in the signal processing circuit. The radiation detection sensitivity of this PED after several test-irradiations to $^{137}Cs$ gamma radiation source appeared to be 1.85 cps/$Gy{\cdot}h^{-1}$ with 19.3% of the coefficient of variation, which satisfied the performance criteria for the active personnel radiation monitor. Further improvement of the electronic circuit and operating program will enable the PED to be used in personal monitoring purpose.

  • PDF

Failure of Cross-Pin Femoral Fixation after Anterior Cruciate Ligament Reconstruction - A Case Report - (전방십자인대 재건술후 대퇴골 경골핀 고정의 실패 - 증례보고 -)

  • Lee Kee-Byoung;Kwon Duck-Joo;Ji Yong-Nam
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.1
    • /
    • pp.92-95
    • /
    • 2003
  • A 34-year-old man with ACL total rupture due to slip down injury, had received ACL reconstruction using autogenous hamstrings tendon with cross-pin femoral fixation. Postoperative course was as usual. But postoperative 3 months later, he complained posterolateral knee pain, recurrent effusion and mild instability. He was managed repeatitive aspiration and nonsteroid antiinflammatory drugs but was failed to relieve symptoms & signs. In CT scans, perforation of posteromedial femoral cortex of lateral femoral condyle was found. In second look arthroscopy, two pieces of broken femoral cross pin were found in between tibiofemoral Joint which was badly injured cartilage. We considered malposition of pins was the main cause of failure. We propose that femoral tunnel must be made more acute angle and femoral cross-pin guide must be positioned more external rotation 10-20 degree than transepicondylar axis made confirm the cross-pin tunnel position in order to avoid posterior cortex perforation and early failure.

  • PDF