• 제목/요약/키워드: Pilot Reactor

검색결과 212건 처리시간 0.027초

호흡률 측정기를 이용한 파일럿 스케일 염색폐수처리 장치에서의 생물학적 활성 측정 (Measurement of Biological Activity in Pilot Scale Dyeing Wastewater Process by Using Respirometer)

  • 전현희;최광근;윤인준;이진원
    • KSBB Journal
    • /
    • 제19권5호
    • /
    • pp.390-393
    • /
    • 2004
  • Oxygen uptake rate (OUR) was used as an indicator of microbial activity. In this study OUR at dyeing wastewater in the pilot plant was monitored to examine biological activity. Correlation between inlet COD concentration and maximum OUR showed that maximum OUR was proportional to inlet COD concentration. Changes in the OUR values reflected the changing waste load in the reactor. Consequently, OUR can be used to estimate biological activity of inlet COD concentration. This study showed that biodegradable COD at dyeing wastewater could be calculated from OUR and yield coefficient. Non-biodegradable COD was able to be calculated from a difference between initial COD concentration and biodegradable COD.

석탄연소 배가스 처리용 플라즈마 탈황탈질 시스템의 운전 특성 (Operational Characteristics of Pilot Scale Plasma DeSOx-DeNOx System for Treatment of Coal-Fired Flue Gas)

  • 장길홍;백민수;김태희;정종한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1806-1808
    • /
    • 1998
  • Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.

  • PDF

경수로 제어봉구동장치제어계통의 영점위상탐지기 성능개선에 관한 연구 (Study for improvement of zero-cross detector of control element drive mechanism control system in PWR)

  • 김병문;이병주;한상준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.609-611
    • /
    • 1996
  • Zero-Cross Detector makes pilot signal to control the power to CEDM(Control Element Drive Mechanism). Existing Zero-Cross Detectors has had a problem which can cause unexpected reactor trip resulted from fluctuating frequency of input signal coming from M/G Set. The existing Zero-Cross Detector can't work properly when power frequency is varying because it was designed to work under stable M/G Set operation, and produces wrong pilot signal and output voltage. In this report the Zero-Cross Detector is improved to resolve voltage fluctuating problem by using new devices such as digital noise filtering circuit, variable cycle compensator and alarm circuit. And through the performance verification it shows that new circuit is better than old one. If suggested detector is applied to plant, it is possible to use it under House Load Operation because stable voltage can be generated by new Zero-Cross Detector.

  • PDF

파일럿 규모 빈 퇴비화 시스템에서 연속 및 간헐 통기 돈분 퇴비의 안정도 평가 (Evaluation of Continuously and Intermittently Aerated Hog Manure Compost Stability in a Pilot-scale Bin Composting System)

  • 홍지형
    • 한국농공학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 1998
  • Compost stability represents the state of microbiological activity and measurements of respiration either through $CO_2$ evolution or $O_2$ uptake should provide the best indication of this state. Hog manure amended with sawdust was composted in a pilot-scale reactor vessels using continuous and intermittent aeration for 3 weeks. In this study we evaluated the $CO_2$ respiration rate effect of aeration method on the reduction of $CO_2$ evolution, and investigated the stability of fresh and finished compost for plant growth. The intermittently aerated composting is a practical proposition for a very stable compost making. The $CO_2$ respiration rate in the fresh and finished compost during intermittently aerated composting was maintained from 0.3 to 1.4 and was good for use in horticulture, while the continuously aerated composting was 7 to 23 and needed more time for compost curing.

  • PDF

$TiCl_4$의 산화반응에 대한 파이롯트 규모 실험 (Pilot Scale Experiments on the Oxidation of $TiCl_4$)

  • 박균영;이익형;양현수
    • 한국세라믹학회지
    • /
    • 제27권6호
    • /
    • pp.817-823
    • /
    • 1990
  • Pilot-scale experiments on the oxidation of TiCl4 to produce TiO2 were carried out in a verical reactor of 20cm in inside diameter and 140cm in length ; LPG burning was used as a heating means to maintain the reaciton temperature. The effects of reaction temperature and excess oxygen content on the conversion of TiCl4 and on the particle size of produced TiO2 were investigated. The ranges of operating conditions varied were 900 to TiO2 was 0.45-0.57${\mu}{\textrm}{m}$, TiCl4 conversion was 82-96%, the rutile content was 33-57% and the contents of impurities were 0.03% of Fe, 0.03% of SiO2 and 62ppm of Cl. These experimental results were compared with those of other investigators.

  • PDF

B3 Pliot plant를 이용한 고농도 질소부하에서의 고도처리에 관한 연구 (The study for Biological nutrient removal of High-strength nitrogen loading rate using B3 pilot plant)

  • 엄태규;한동엽;김부길
    • 한국환경과학회지
    • /
    • 제14권8호
    • /
    • pp.771-775
    • /
    • 2005
  • The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT l0hour, IR(Internal Recycle) $150\%$ and used $2.8m^3$ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 $mgNH_4^+-N/gSS/d$ during operation periods and denitrification rate was $3.l2mgNO_3^--N/gSS/d.$ When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.

광합성세균의 파이롯트 단위 생산을 위한 고순도 배양 (Highly Pure Culture of Photosynthetic Bacteria for Pilot-scale Production)

  • 조경숙;임태빈;정해윤;조정섭;김중균
    • 한국해양바이오학회지
    • /
    • 제1권4호
    • /
    • pp.292-297
    • /
    • 2006
  • 오염된 양식 해수의 수질정화능력이 뛰어난 광합성세균의 고순도 대량배양을 위한 실험을 실험실 단위 및 파이롯트 단위에서 수행했다. Gas pack 반응기, flask 반응기 및 N-source로서 질소 가스를 사용한 실험 결과, 광합성세균은 현미경상 약 90%이상의 순도를 나타내었고, CFU 측정 결과에서도 붉은색을 띄는 광합성세균 colony만을 관찰 할 수 있었다. 배지의 교차에 의한 배양실험에서 기초배지를 이용한 배양이 광합성세균의 성장에 가장 효과적임을 알 수 있었다. 이러한 배양조건하에서의 5L bioreactor 배양에서 비증식속도가 $0.18h^{-1}$로 나타났고, 실험실 단위의 결과를 이용한 pilot 단위에서의 배양결과, 실험실 단위의 비증식속도와 동일한 값을 얻을 수 있었다.

  • PDF

소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가 (Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment)

  • 안진영;권중천;김윤학;정유훈;김두언;유선호;김병우
    • 청정기술
    • /
    • 제12권2호
    • /
    • pp.67-77
    • /
    • 2006
  • 본 연구에서 소규모 하수고도처리를 위한 이중슬러지(Dual sludge) $KNR^{(R)}$ (Kwon's nutrient removal) 시스템이 개발되었다. $KNR^{(R)}$ 시스템은 부유성장식 탈질미생물과 부착성장식 질산화미생물을 분리시킨 이중슬러지 공정으로 최초침전조, 혐기조, 무산소조, 농축조의 복합기능을 수행하는 UMBR (Upflow multi-layer bioreactor)과 펠렛형 담체가 충진된 호기성 담체조로 구성되어 있다. 소규모 하수처리시 본 개발공정의 안정성과 처리성능을 평가하기 위해 처리용량 $50m^3/d$ 규모의 파일럿 플랜트를 고도처리 공정으로 개선공사 중인 처리용량 $50m^3/d$ 규모의 실제 소규모 마을하수처리장에 적용하였다. UMBR과 담체조의 체류시간은 각각 4.7 h와 7.2h이었으며, 반응조 수온은 $18.1{\sim}28.1^{\circ}C$이었다. 유입 하수량과 유입수의 BOD/N의 변동폭이 컸음에도 불구하고 파일럿 플랜트는 안정된 처리성능을 보였다. 전체 실험기간 중 처리수의 $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, TP의 평균 농도는 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, 0.87/0.17 mg/L (poly aluminium chloride(PAC) 투입/미투입)이었으며, 제거율을 각각 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, 55.4/90.3% 이었다. 잉여슬러지 발생량은 $A_2O$와 Bardenpho 등과 같은 단일슬러지를 이용하는 고도처리공정과 비교시 약 1.9~3.8배 낮은 $0.026kg-DS/m^3$ and 0.220 kg-DS/kg-BOD로 나타났다.

  • PDF

발전용 역청탄 및 아역청탄의 파일롯 연소특성 평가 (Combustion Characteristics of Imported Bituminous & Subbituminous Coal in a Pilot Scale Test Facility)

  • 김현희;박호영;임현수;백세현;김태형;김영주;공지선;이정은
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.207-214
    • /
    • 2014
  • 고급탄의 고갈에 따라 석탄화력발전소에서의 저급탄 혼소가 필수불가결하게 되었다. 본 연구에서는 국내에서 수입되는 석탄 중에서 대표적으로 사용되는 역청탄과 아역청탄에 대한 연소특성을 0.7MWth 파일롯 연소실험장치를 사용하여 측정, 분석하였다. 과잉공기비가 1.2인 상태에서 축방향 및 반경방향의 노내 가스온도 및 주요 가스농도를 측정하였으며, 역청탄 연소시 반응로 내의 입자 샘플링을 수행하였다. 두 탄종의 주반응영역은 노 상부의 스월버너로부터 약 1m 근방에서 형성되었으며, 노 하류에서는 완전 확립된 온도와 농도분포를 나타내었다. 포집된 역청탄의 고체입자 분석으로부터 주반응영역 이후에 완전한 탄소전환이 이루어진 것을 확인하였다.

펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구 (A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor)

  • 최민;박소진;위영호
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.