Verifications of the Impact-echo Technique for Integrity Evaluations of the Drilled Shaft using Full Scale Tests (현장시험에 의한 충격반향기법의 말뚝 건전도 검사 적용성 평가)

  • Jung, Gyung-Ja;Cho, Sung-Min;Kim, Hong-Jong;Jung, Jong-Hong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.33-40
    • /
    • 2005
  • Impact-echo test, a kind of simple and economical method to evaluate the integrity of drilled piles has some limitations to use because the stress wave can be generated only on the head of a pile and the wave propagation in the pile with surrounding soils are very complicated. Numerical analyses and model tests in the laboratory have shown that both the ratio of length to diameter of a pile and the stiffness ratio of pile to soil have influence on the resolution of testing results. Full scale testing piles which have artificial defects were used to verify the capability of impact-echo technique as a tool for the pile integrity evaluation. Behaviour of the reflected signal of stress wave was investigated according to the type of defects. Elastic modulus of the pile was calculated using the wave velocity in the pile and the unconfined strength of concrete specimen. Influences of the stiffness difference between the pile and the ground on the characteristics of a wave signal were also examined.

  • PDF

Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles (확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구)

  • Kim, Myunghak;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.115-131
    • /
    • 2018
  • Extension plate attached PHC piles and bolts spliced PHC piles were installed in field test site. Pile integrities were checked during installation with dynamic pile test and the actual pile conditions after installation were compared with integrity index (${\beta}$ index) by PDA test. Theoretically the break in near pile end or pile end (especially extension plate itself) was very difficult to access by integrity index (${\beta}$ index) and also require a high level of knowledge and field experience on PDA test. First actual wave equation of bolts spliced PHC piles due to bolts spliced equipment can be different with welding spliced. Second wave length of the stress wave from installing can be longer than the height of bolts spliced equipment (about 100 mm). Third Beta processing in PDA analysis function is very difficult to access without a high level of knowledge and field experience on wave equation. Above-mentioned three reasons can make conclusion that traditional PDA test in domestic site can not access the integrity of bolts spliced equipment in bolts spliced PHC piles.

Development of Non-Destrutive Pile Soundness Test Using HWAW Method (HWAW(Harmonic Wavelet Analysis of Wave) 방법을 사용한 말뚝기초의 비파괴 건전도 평가방법의 개발)

  • Park, Hyung-Choon;Kim, Dong-Soo;Cho, Sung-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.8
    • /
    • pp.13-23
    • /
    • 2008
  • The evaluation of soundness of pile is very important for the safety of super structure. In this paper, the HWAW(Harmonic Wavelet Analysis of Wave) method which is developed to determine phase and group velocities of waves is applied to evaluate integrity of pile non-destructivly. The proposed method can evaluate a soundness of pile and pile end condition which is very important factor for pile behaviour. To verity the applicability of HWAW method in non-destructive test for pile, the numerical simulation test using ABAQUS was performed. And the model pile was made and the proposed non-destructive pile tests were applied to evaluate soundness and end boundary condition of model pile in the air and soil box. Through a numerical simulation and model tests, it is shown that the HWAW method has good potential of applying to the evaluation of pile integrity.

Pile Integrity Test Examples for Displacement in-situ Concrete Piles (소구경 현장타설 콘크리트 말뚝의 건전도 시험사례)

  • 이명환;홍헌성;김성회;전영석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.423-430
    • /
    • 1999
  • PIT collector를 이용한 저변형률 건전도시험(low strain pile integrity test)은 충격에 의해 발생하는 응력파장의 특성을 분석하여 말뚝의 길이와 형상을 추정하는 방법이다. PIT시험(Pile Integrity Test)은 장말뚝인 경우와 지반저항이 큰 경우 선단부의 위치가 분명하게 확인되지 않아 해석이 불가능하다는 단점이 있으며 적용할 수 있는 대상말뚝에도 종류에 따라 제한된다. 그러나 이밖의 경우 간편성과 말뚝의 대략적인 단면형상을 파악할 수 있다는 점에서 다른 방법에 비하여 유리하다. 이 때문에 국내에서도 PIT시험의 적용 빈도가 증가하는 추세이며 지난 3~4년 동안 주로 대형 교량건설 현장의 대구경 현장타설말뚝에 대하여 적용되어 왔다. 최근 국내에서는 대구경 현장타설말뚝이 아닌 소구경 현장타설말뚝에 대하여 PIT시험을 실시하는 경우도 증가하고 있다. 현장 조건상 말뚝길이가 길지 않은 경우 시험분석결과 말뚝의 선단부가 분명하게 확인되었고 말뚝 중간부 및 하부의 necking 또는 bulging, 선단부의 단면이 확대되거나 축소되는 형상 등 다양한 단면형상을 나타내었다. 이 결과로부터 건전도시험의 효과적인 분석방안, 시간(양생)효과 등을 판단할 수 있음을 확인할 수 있었다.

  • PDF

Verifications of the Impact-echo Technique for Integrity Evaluations of the Drilled Shaft Using Full Scale Tests (현장시험에 의한 충격반향기법의 말뚝 건전도 검사 적용성 평가)

  • Jung Gyungja;Cho Sung-Min;Kim Hong-Jong;Jung Jong-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.207-214
    • /
    • 2005
  • The reflected signals from the defects of a pile and the boundaries between the pile and soils are analyzed to evaluate the integrity of drilled shafts in the impact-echo test. Signals varied according to both of the stiffness ratio of the pile to defects and that of the pile to surrounding soils. Model tests using the small size pile in the laboratory and numerical analyses have limitations in finding the characteristics of the signals due to different stress wave characteristics and unreliable modelling for the interaction between the pile and soils respectively. Full scale testing piles which have artificial defects are installed by the actual construction method and they were used to investigate the characteristics of reflected signals according to defects and the stiffness ratios of the pile to soils around.

Geotomography Applied for the Integrity Test of Cast-in-place Piles (현장타설콘크리트말뚝의 건전도 평가를 위한 geotomography의 적용 연구)

  • Lee Jae-Kyung;Park Jong-Nam
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.5-12
    • /
    • 2005
  • Recently, geophysical prospecting methods have played very important roles in civil and environmental engineering problems. Technical advances in geophysical instruments and computer system made it possible to get underground images with very high resolution far purposes to resolve those problems. It was possible partly due to ever increasing demand for development of technologies needed to precisely detect polluted areas and prevent ground-related accidents. Based on the same demand, integrity tests of cast-in place piles draw more attention and development of accurate test procedures is required. Ultrasonic methods is one of most advanced non-destructive procedures. In the paper, a geotomography method is employed for the cast-in place pile integrity test using ultrasonic waves. The image of pile interior is scanned and scrutinized far better and more accurate decision in the cast-in place pile integrity. In this study, we firstly examined the accuracy fur tomography program with idealized synthetic models built in water tank: their position and size were changed in the tank and each case was studied. In the next stage, real concrete pile models were fabricated and images of anomaly areas inside the pile were scanned to successfully locate those areas.

Analysis on inclined or rounded tip piles using 3D printing technology and FE analysis

  • Jaehong Kim;Junyoung Ko;Dohyun Kim
    • Geomechanics and Engineering
    • /
    • v.33 no.1
    • /
    • pp.91-99
    • /
    • 2023
  • To test the effect of various pile tip shape series of model scale loading tests were carried out on test piles with special pile tips. Special pile tips were made using the 3D printer and were attached to the bottom end of the test pile for loading tests. The pile tips were made to have 30°, 45°, 60° inclined tips, as well as a rounded tip. The main objective of the test was to observe the effect of various pile tip shapes on settlement and penetrability of the pile. Moreover, a numerical model simulating the pile loading test carried out in this study was established and verified based on the loading test results. From this, the stress concentration around the pile tip was investigated. This will allow us to analyze the decrease of stress concentration around the pile tip which is the main cause of the pile tip damage during pile installation. However, modifying the pile tip shape will eventually increase the settlement of the pile. By estimating the degree of increase in pile settlement, the viability and the efficiency of the pile shape modification was judged. In addition, case studies on the effect of different pile tip shape and ground conditions on pile settlement and stress dispersion was conducted.

A Proposal for the Proper Application of Dynamic Pile Loading Tests (동재하시험의 올바른 적용)

  • 홍헌성;김성회;전영석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.233-240
    • /
    • 1999
  • Locally PDA has been utilized mainly as an alternative way of preforming pile loading tests. More than 30 units of PDA's are believed to be operating in Korea. It is true that PDA can provide useful information regarding bearing capacity, integrity, hammer performance, time effect, etc. However it is also true that inappropriate execution of PDA could result in harmful effects for the safety of the superstructure or causing delay in the construction process. In this paper several cases of inappropriate application of PDA are introduced. Most of the problems seemed to be caused by unqualified personnel who carry out testing and analysis. From the evaluation of the cases a proposal has been made for the proper application of PDA.

  • PDF

The effect of group pile installation (무리말뚝 시공의 영향)

  • Lee, Myung-Whan;Hong, Hun-Sung;Kim, Sung-Hoi;Jun, Young-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1303-1311
    • /
    • 2006
  • Most of the piles are designed as group piles. In certain geotechnical environments, the installation of group piles causes heaving of the already installed piles. The unfavorable effects of pile heaving on pile bearing capacity have been well known to field engineers. However not many engineers pay enough attention to this subject. According to our recent researches, not only the bearing capacity but also the pile material could be seriously damaged due to the installation of nearby piles, especially with the cases of precast concrete piles. When the pull-out force due to installation of neighboring piles acting on the already installed precast concrete pile exceeds the shaft friction, pile heaving occurs. At the same time, if the pull-out force exceeds the allowable tensile strength of the precast concrete pile, tensile failure is inevitable, which is critical for the pile integrity. In other cases the pile material was not damaged but serious relaxation occurred as the results of pile heaving. In this paper, the pull-out mechanism due to the installation of group piles is explained.

  • PDF

A Study on Hammer Performance Evaluation (항타장비의 성능평가 연구)

  • 홍헌성;이명환;조천환;김성회;전영석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.405-412
    • /
    • 2002
  • The performance of a hammer/driving systems is a major factor which affects bearing capacity and integrity of installed piles. Hammer performance can be evaluated from the results of dynamic pile testing using Pile Driving Analyzer(PDA). By comparing the rated energy with measured maximum transferred energy(EMX), the energy transfer ratio(ETR) can be calculated. This paper based on the dynamic measurements of 442 cases in 130 piling projects and evaluated ETR according to the hammer types(hydraulic and drop hammers) and pile types(steel and concrete piles).

  • PDF