• 제목/요약/키워드: Pig-housing

검색결과 55건 처리시간 0.036초

돈방의 구조가 자동급이기를 활용한 임신돈의 섭식행동에 미치는 영향 (The Effects of Housing Design on the Feeding Behaviors of Group Housed Pregnant Sow with Electronic Sow Feeder)

  • 송준익;김지향;전중환;이준엽
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.167-172
    • /
    • 2014
  • This study was conducted to evaluate the housing design on the feeding behaviors of group housed pregnant sows. A total of 65 sows (Landrace ${\times}$ Yorkshire) were employed into 2 experimental sow housing with different housing design. Lying area of one of sow housing was designed with concrete fence to give the shelter for weak sows. The other was floor type without any obstacles. Group housed sows were fed using electronic sow feeder (ESF) during gestation. Daily feeding pattern of sows was automatically recorded in ESF feeder program. Most sows ate all feed during night. Daily visiting frequency to ESF of sows in pig pen with the shelter was significantly lowered than sows in floor type pen. This study showed that the housing design of group housed sow pen could fairly impact ESF utilization of sow.

Better Housing for Effective Pig Production - Review -

  • Choi, H.L.;Song, J.I.;An, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권8호
    • /
    • pp.1310-1315
    • /
    • 1999
  • Air quality in confinement pig houses is important to production and health. Mechanical ventilation and confinement is known to be the most practical tool for maintaining adequate air quality in pig houses through extensive researches since Millier (1950) invented the 'slotted inlet' ventilation system. A variety of mechanical ventilation systems have been applied to confined nursery pig houses in Korea without scientific verification of their ventilation effectiveness. Ventilation systems with three feasible combinations (NA, NB, and NC) of inlets and outlets in a confined nursery pig house were tested to evaluate their ventilation efficiency, of which the one with the performance was supposed to be taken as a standard ventilation system for nursery pig houses in Korea. Field data of air velocity and temperature fields, and ammonia concentration with three ventilation systems were taken and compared to determine the best system. The air velocity and temperature fields predicted by the PHOENICS computer program were also validated against the available experimental data to investigate the feasibility of computer simulation of air and temperature distribution with an acceptable accuracy in a confined house. NC system with duct-induced in-coming air, performed best among the three different ventilation systems, which created higher velocity field and evener distribution ($2.5m/s{\pm}0.3m/s$) over the space with a Reynolds number of $10^4$. The experimental data obtained also fitted well with the simulated values using the modified PHOENICS, which suggested a viable tool for the prediction of air and temperature field with given calculation geometries.

돈사내 암모니아가스 계측시스템 개발 (Development of a Measurement System for Ammonia Gas in Swine Housing)

  • 방승훈;장동일;장홍희;임영일
    • Journal of Biosystems Engineering
    • /
    • 제23권4호
    • /
    • pp.359-364
    • /
    • 1998
  • A PC based measurement system was developed and it consisted of ammonia sensor(TS-1000), AMP & MUX Board, A/D Converter, and personal computer. The results obtained from the study are summarized as follows : 1. The relationship of outputs(V) of ammonia sensor(AS) and concentrations(ppm) of ammonia gas was analyzed by the linear regression analysis and the output values were very accurate when compared with standard ammonia gas. 2. The test results showed that the performance of ammonia gas sensor was not 31B3c1e4 by temperatures and humidities 3. The developed ammonia gas measurement system was proved to be practically uesful for measuring concentrations of ammonia gas in pig housing.

  • PDF

국내 양돈장의 사육 온도와 밀사율이 구강액 채취율에 미치는 영향 (The effect of temperature and breeding density of piggery on the collection of oral fluid in Korea)

  • 변현섭;김미화;권성애;한미나;한성태;장래훈;정윤수;김석현;전보영
    • 한국동물위생학회지
    • /
    • 제44권4호
    • /
    • pp.217-225
    • /
    • 2021
  • We investigated the effect of temperature and stock density on the collection efficiency of oral fluid in the pig farm in Korea. Three pig farms with similar breeding environmental conditions were selected and four pens of each farm (total 12 pens) were tested for the collection efficiency of oral fluid from pigs. Collection rate was considered as significant when oral fluid was collected from 70% of pigs within a pen. In the case of growing pigs, when internal temperature of pig barn increased by one designated degree (5℃), the oral fluid collection rate significantly decreased by 24.7% (P<0.05). The collection rate of oral fluid also decreased by 7.1% (P<0.05) as the density rate increase by one designated degree (12.5%). It was estimated that the collection efficiency of oral fluid decreased when the internal temperature of pig barn was 30℃ or higher, or barn density is higher 25% or high. On the other hand, in the case of stall-housing sows, unlike growing pigs, there was no significant differences according to the temperature, so oral fluid collection was considered to be efficient even in hot season.

Minimizing the Environmental Pollution of Pig Husbandry and Waste Management

  • Mszros, Gy;Kuli, B.;Fenyvesi, L.;Mtys, L.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1395-1404
    • /
    • 1993
  • Application of water-saving self-feeders can reduce water consumption of pigs by more than 50% . so the feeding-watering system one of the most important way of the reduction of the slurry. Bioactive deep litter housing can eliminate slurry. Matured urine, faeces and litter can use for the purposes of soil conditioning and fertilizing . Water-saving slurry handling technology can halve manure dilution so it can double the nutrient content of the slurry. By using of straw bale biofilter for reducing emissions of pig houses makes fattening of pigs possible close to populated area. Developed rate control system for slurry application make avoiding over-fertilization possible , can fulfill better the demand of nutrient of plants. By means of computer aided manure utilization system area distribution of soil characteristics can determinate . The system is suitable for planning the utilization of manure and slurry in environment -friendly way.

  • PDF

Antimicrobial resistance in fecal Escherichia coli from different pig production systems

  • Mitchaothai, Jamlong;Srikijkasemwat, Kanokrat
    • Animal Bioscience
    • /
    • 제35권1호
    • /
    • pp.138-146
    • /
    • 2022
  • Objective: The objective of the current study was to investigate the influences of conventional (CO) and deep litter (DE) systems on antimicrobial resistance in fecal Escherichia coli (E. coli). Methods: A cross-sectional study was carried out to detect antimicrobial resistance to E. coli in swine fecal samples in CO and DE systems located in western and northeastern Thailand. Individual rectal swab samples were taken only from healthy pigs. A total of 215 individual and healthy pigs were randomly selected for isolation and antimicrobial susceptibility test of E. coli by the disc diffusion method. The test panel included amoxicillin (AMX), colistin, doxycycline (DOX), enrofloxacin, gentamicin (GEN), kanamycin, neomycin (NEO), and trimethoprim-sulfamethoxazole (SXT). Results: There were significant (p<0.05) lower resistance levels for GEN, NEO, and SXT in the DE farms compared to those in the CO farms. There was a lower number of antimicrobial resistance agents (p<0.001) in the DE farms compared to those in the CO farms. This result was consistent with those in western (p<0.01) and northeastern (p<0.01) Thailand. Overall, antibiograms of AMX-SXT and AMX-DOX-SXT were found in the CO (19.09% and 20.91%, respectively) and the DE (16.19% and 24.76%, respectively) farms. No antimicrobial resistance (5.71%) was found and AMX (13.33%) resistant pigs in the DE farms, whereas the pattern of AMX-GEN-SXT (6.36%) and AMX-DOX-GEN-SXT (11.82%) resistant pigs was found in the CO farms. Conclusion: The DE system for pig farming was superior to conventional pig farming by lowering the resistance level of fecal E. coli to GEN, NEO, and SXT, with decreasing the number of antimicrobial resistance agents and inducing a small proportion of pigs to be free from antimicrobial resistance.

돈사환경 개선을 위한 생육단계별 돈사내 악취물질 농도 및 유해가스의 1일 변화추세 분석 (Analysis of Changing Pattern of Noxious Gas Levels with Malodorous Substance Concentrations in Individual Stage of Pig Pens for 24 hrs to Improve Piggery Environment)

  • 유원균;김초롱;이명규;김동균
    • 한국축산시설환경학회지
    • /
    • 제18권1호
    • /
    • pp.25-34
    • /
    • 2012
  • 1. 돈사의 유형별 시간대에 따른 공기품질의 변화패턴을 알아본 결과 돈사 실내의 온 습도, 먼지농도, 실내기체의 조성 등이 주간과 야간의 편차가 크게 나타났으며, 대부분의 돈사는 주간시간대인 12:00경의 실내 환경조건이 가장 양호하였고 00:00~06:00 사이의 공기조성이 가장 불량한 것으로 나타났다. 2. 돈사의 유형별 공기품질이 양호한 곳은 임신돈사와 분만돈사였으며, 불량한 돈사는 육성돈사와 비육돈사 이었다. 공기의 품질이 양호하였던 임신돈사의 경우, 슬러리 형태로서 분과 뇨의 분리가 잘 이루어진 결과였으며, 분만돈사의 경우는 돈사당 사육두수에 비하여 포유자돈의 배설량이 적었기 때문이었다. 반면, 공기품질이 불량한 육성돈사 및 비육돈사는 분뇨배설량이 많을 뿐 아니라 분뇨의 적체시간이 긴 구조적 특성이 작용한 결과였다. 또한 분만돈사의 경우, 심야시간대인 00:00 부터 06:00 사이에 일산화탄소와 이산화탄소의 함량이 크게 증가하는 현상을 보였는데 이것은 이 시간대의 공기품질이 자돈폐사율의 증가요인이 될 수 있음을 시사한다. 3. 그러므로 돈사의 환경을 개선하려면, 실내 악취발생을 최소화할 수 있는 시설구조, 적합한 사육밀도의 조절 및 자동감지 환기 시설 등이 매우 중요한 요소라고 하겠다.

돈사용 환기팬을 위한 돈사 내 온도 분포 특성 (Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System)

  • 김현태;김웅
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

돼지 생육 단계에 따른 계절별 암모니아와 황화수소의 돈사 내 농도 비교 (Comparison of Seasonal Concentration of Ammonia and Hydrogen Sulfide in Swine House according to Pig's Growth Stage)

  • 김기연;고한종;김현태
    • 농업생명과학연구
    • /
    • 제46권2호
    • /
    • pp.163-168
    • /
    • 2012
  • 본 연구의 목적은 강제환기가 적용되는 슬러리 돈사를 대상으로 돼지 생육 단계별 돈방 유형 측면과 계절적 조건에 따른 암모니아와 황화수소의 실내 농도를 측정 분석하여 정량화하는 데 있다. 임신/분만 돈방의 경우 봄철은 5.60(${\pm}2.48$) ppm과 178.4(${\pm}204.8$) ppb, 여름철은 2.51(${\pm}3.08$) ppm과 86.6(${\pm}112.5$) ppb, 가을철은 4.96(${\pm}2.84$) ppm과 182.3(${\pm}242.6$) ppb, 겨울철은 6.82(${\pm}3.42$) ppm과 206.3(${\pm}356.8$) ppb로, 자돈방의 경우 봄철은 7.18(${\pm}3.26$) ppm과 486.0(${\pm}190.2$) ppb, 여름철은 4.23(${\pm}2.95$) ppm과 206.4(${\pm}186.9$) ppb, 가을철은 7.02(${\pm}2.65$) ppm과 465.4(${\pm}156.8$) ppb, 겨울철은 9.25(${\pm}3.68$) ppm과 618.4(${\pm}298.3$) ppb로, 육성/비육 돈방의 경우 봄철은 9.26(${\pm}3.02$) ppm과 604.4(${\pm}186.8$) ppb, 여름철은 6.78(${\pm}3.88$) ppm과 312.5(${\pm}215.4$) ppb, 가을철은 9.34(${\pm}2.14$) ppm과 578.2(${\pm}248.1$) ppb, 겨울철은 14.65(${\pm}3.15$) ppm과 825.3(${\pm}316.9$) ppb로 분석되었다. 측정 결과 암모니아와 황화수소 모두 돼지 생육 단계별 돈사 유형 측면에서는 육성/비육 돈사>자돈사>임신/분만 돈사의 순서로 나타났고(p<0.05), 계절적 측면에서는 겨울>봄>가을>여름 순서로 조사되었으나 봄철과 가을철 데이터 간의 차이는 통계적으로 입증되지 않았다(p>0.05).

돈사 작업장 유형에 따른 입자상 오염물질의 실내농도 및 발생량에 관한 현장 조사 (Field Study of Concentrations and Emissions of Particulate Contaminants by Types of Swine Houses in Korea)

  • 김기연;박재범;김치년;이경종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권2호
    • /
    • pp.141-146
    • /
    • 2005
  • Objectives: Particulate contaminants, such as total and respirable dusts, can harm the health of farm workers via several routes. The principal aims of this field study were to determine the concentrations and emissions of particulate contaminants: total and respirable dusts, in the different types of swine houses used in Korea, and allow objective comparison between Korea and the other countries in terms of swine housing types. Methods: The swine houses investigated in this research were selected with respect to three criteria: the manure removal system, ventilation mode and growth stage of pigs. Measurements of total and respirable dust concentrations and emissions in the swine houses were carried out on 5 housing types at 15 different farm sites per housing type. The swine houses investigated were randomly selected from farms situated within the central districts in Korea: province of Kyung-gi, Chung-buk and Chung-nam. Results: The total and respirable dust concentrations in the swine houses averaged $1.88\;and\;0.64mg/m^3$, ranging from $0.53\;to\;4.37mg/m^3$ and from $0.18\;to\;1.68mg/m^3$, respectively. The highest concentrations of total and respirable dusts were found in the swine houses with deep-litter bed systems: $2.94mg/m^3\;and\;1.14 mg/m^3$, while the lowest concentrations were found in the naturally ventilated buildings with slats: $0.83mg/m^3\;and\;0.24mg/m^3$, respectively (p<0.05). All the swine houses investigated did not exceed the threshold limit values (TLVs) for total ($10mg/m^3$) and respirable ($2.5mg/m^3$) dusts. The mean emissions of total and respirable dusts, per pig (75 kg in terms of live weight) and area ($m^2$), from the swine houses were 97.33 and 9.55 mg/h/pig and $37.14\;and\;12.83mg/h/m^2$, respectively. The swine houses with deep-litter bed systems showed the highest emissions of total and respirable dusts (p<0.05). However, the emissions of total and respirable dusts from the other swine houses were not significantly different (p>0.05). Conclusion: The concentrations and emissions of total and respirable dusts were relatively higher in the swine houses managed with deep-litter bed systems and ventilated naturally of the different swine housing types tested. In further research, more farms than the number used in this research should be investigated, which will present objective and accurate data on the concentrations and emissions of total and respirable dusts in Korean swine houses. In addition, personal sampling should be performed to objectively assess the exposure level of farm workers to particulate contaminants.