• 제목/요약/키워드: Piezoelectric pressure transducer

검색결과 44건 처리시간 0.027초

프로판-공기 예혼합기의 화염전파 과정에 관한 연구 (Flame Propagation Characteristics of Propane-Air Premixed Mixtures)

  • 배충식
    • 한국연소학회지
    • /
    • 제1권2호
    • /
    • pp.21-29
    • /
    • 1996
  • Flame propagation characteristics of propane-air mixtures were experimentally investigated in constant-volume combustion chambers. Flame propagation process was observed as a function of mixture strength, initial mixture temperature and initial mixture pressure in quiescent mixtures. A cylindrical combustion chamber and a spherical combustion chamber contain a pair of parallel windows through which optical access into the chamber can be provided. Laser two beam deflection method was adopted to measure the local flame propagation, which gave information on the flame size and flame propagation speed. Pressure development was also measured by a piezoelectric pressure transducer to characterize combustion in quiescent mixtures. Burning velocity was calculated from flame propagation and pressure measurements. The effect of flow on flame propagation was also investigated under flowing mixture conditions. Laser two beam method was found to be feasible in measuring flame propagation of quiescent mixtures. Flame was observed to propagate faster with higher initial mixture temperature and lower initial pressure. Combustion duration was shortened in the highly turbulent flowing mixtures.

  • PDF

정적연소기에서의 메탄-공기 혼합기의 연소특성(2) : 비균질급기 (Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(2) : Inhomogeneous Charge)

  • 최승환;전충환;장영준
    • 한국자동차공학회논문집
    • /
    • 제11권4호
    • /
    • pp.29-36
    • /
    • 2003
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at spark plug and the combustion characteristics of inhomogeneous charge methane-air mixture under several parameters. The flow characteristics such as mean velocity and turbulence intensity was analyzed by hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer was used to investigate the effect of initial charge pressure, excess air ratio and ignition times on combustion pressure and combustion duration. Mean velocity and turbulence intensity had the maximum value at 200 or 300ms and then decreased to beneath 0.05m/s gradually at 3 seconds. Second mixture is accompanied by an increase in the combustion rate, and that the higher the mass which is added in the second stage injection, the faster the burn rate.

원통형 진동자 내부의 이중관 중심에서의 음압해석 (An analysis of acoustic pressure in the center of double pipe inside of a cylindrical vibrator)

  • 김정순;김무준
    • 한국음향학회지
    • /
    • 제36권3호
    • /
    • pp.165-171
    • /
    • 2017
  • 유체로 채워진 원통형 압전진동자 내부에서 중심축으로 집속되는 음파에 대해 진동자 내부에 삽입된 동심원의 고체튜브가 음장분포에 미치는 영향을 해석하였다. 원통형 압전진동자의 내부로부터 방사된 음파는 유체매질을 지나 고체튜브의 벽면에서 반사 및 투과를 하여 중심축에 집속된다. 이때 고체튜브의 음향임피던스 및 두께 등에 의해 중심에 집속되는 음장 분포가 변한다. 이를 이론적으로 해석하기 위하여 각 매질에 대한 전달행렬을 도출하였고 이를 적용하여 중심축에서의 음압수준을 이론적으로 해석하였다. 여러 가지 두께를 갖는 아크릴 튜브에 대해서 중심축 상에서 측정한 음압수준의 변화는 이론해석의 결과와 잘 일치하였으며 중심에 형성되는 음압은 고체튜브의 두께에 따라 매우 민감하게 변화함을 확인하였다.

A Study for the Measurement of a fluid Density in a ripe Using Elastic Waves

  • Kim, Jin-Oh;Hwang, Kyo-Kwang;Bau, Haim-H.
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.583-593
    • /
    • 2003
  • The effect of liquid confined in a pipe on elastic waves propagating in the pipe wall was studied theoretically and experimentally. The axisymmetric motion of the wave was modeled with the cylindrical membrane shell theory. The liquid pressure satisfying the axisymmetric wave equation was included in the governing equation as a radial load. The phase speed of the wave propagating in the axial direction was calculated, accounting for the apparent mass of the liquid. Experiments were performed in a pipe equipped with ring-shaped, piezoelectric transducers that were used for transmitting and receiving axisymmetric elastic waves in the pipe wall. The measured wave speeds were compared with the analytical ones. This work demonstrates the feasibility of using pipe waves for the determination of the density and, eventually, the flow rate of the liquid in a pipe.

초음파 음장해석 및 가시화를 통한 선형 위상차배열 트랜스듀서의 결함요소 검출 가능성 연구 (Feasibility Study on Detection of Defective Elements in a Linear Phased Array Transducer through Ultrasonic Field Analysis and Visualization)

  • 최광윤;양정원;하강렬;김무준;김정순;이채봉
    • 한국음향학회지
    • /
    • 제28권5호
    • /
    • pp.416-423
    • /
    • 2009
  • 16개 압전요소로 구성된 3 MHz의 선형 위상차배열 초음파 트랜스듀서를 대상으로, 모든 압전요소가 정상일 때와 임의의 요소 하나가 결함으로 인해 동작하지 않을 때의 음장을 이론적으로 시뮬레이션하고, 슈리렌법에 따라 구축한 음장가시화장치를 이용하여 실험적으로 측정하였다. 조향각 $0^{\circ}$$30^{\circ}$일 때 각각에 대한 시뮬레이션의 결과, 임의의 압전요소가 결함으로 인해 동작하지 않을 때의 음장은 모든 요소가 정상적으로 동작할 때의 음장에 비해 부엽 패턴이 크게 다르게 나타나며, 그 형태는 가시화에 의한 측정결과와 잘 일치하였다. 따라서, 가시화 장치에 의해 측정된 2차원 음장에서의 부엽패턴을 시뮬레이션 결과와 비교 분석함으로써 선형 위상차배열 초음파 트랜스듀서의 결함요소 검출이 가능함을 알았다.

미세 압전 캔틸러버를 이용한 마이크로 폰 및 마이크로 스피커

  • 이승섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.347-351
    • /
    • 1997
  • A micromachined piezoelectic cantilever transducer,which works both as a microphone and as a microspeaker,has been fabricated and tested. The 2000*2000*3.mu.m .sap2. cantilever has oxide(ZnO)piezoelectric thin film on a supporting layer of low-pressure chemical-vapor-deposited(LPCVD)low-stress siliconnitride. A highlight of the fabrication process which may also be relevant for other micromachined stuctures is the technique for producing a flat,multilayer cantilever. The measured microphone sensitivity is fairly constant at 2 mV/.mu.bar in the low frequency range and rise to 20 mV/.mu.bar at the lowest resonant frequency of 890 Hz. The 2 mV/.mu.bar sensitivity is the highest report to data for a microphone with a micromachined diaphragm. When measured into a 2 cm/sap3 coupler with 4V (zero-park)drive,the microspeaker output sound pressure level(SPL) is 75 dB at 890 Hz. It increases to approximately 100dB SPL at 4.8kHz with 6V(zero-park)drive. The measured microphone frequency response agrees well with the results of an ABAQUS simulation.

액체의 과열한계 측정과 과열한계에 달한 액적의 거동 (Measurement of the Superheat Limit of Liquids and Droplet Behavior at this Limit)

  • 박홍철;변기택;곽호영
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1317-1326
    • /
    • 2003
  • The maximum temperature limit at which liquid boils explosively is called the superheat limit of liquids. The superheat limits of hydrocarbon liquids and their mixtures were measured by the droplet explosion technique. Also the fully evaporated droplet at the superheat limit and subsequent bubble evolution from the fully evaporated droplet were visualized. The pressure wave emanating from the evaporating droplet and subsequent bubble evolution process were measured by a piezoelectric transducer.

Giant Piezoelectric Nanocomposites Integrated in Physically Responsive Field-effect Transistors for Pressure Sensing Applications

  • Tien, Nguyen Thanh;Trung, Tran Quang;Kim, Do-Il;Lee, Nae-Eung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.550-551
    • /
    • 2012
  • Physically responsive field-effect transistors (physi-FETs), which are sensitive to physical stimuli, have been studied for decades. However, the primary issue of separating responses by sensing materials from interferences by other subcomponents in a FET transducer under global physical stimuli has not been completely resolved. Recent challenges of structural design and employing smart materials with a large electro-physical coupling effect for flexible physi-FETs still remain. In this article, we propose directly integrating nanocomposites of barium titanate (BT) nanoparticles (NPs) and highly crystalline poly(vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)) as gate dielectrics into flexible organic FETs to precisely separate and quantify tiny variations of remnant polarization caused by mechanical stimuli. Investigations under static stimuli resulted in first-reported giant-positive piezoelectric coefficients of d33 up to 960 pC/N, presumably due to significant contribution of the intrinsic piezoelectricity of BT NPs and P(VDF-TrFE) crystallites. This approach provides a general research direction, and not limited to physic-FETs.

  • PDF

압축착화 디젤엔진의 모사 EGR 시스템에 의한 소음 특성 변화 분석 (Study on Noise Generation Characteristics of Simulated EGR System for Compression Ignition Diesel Engine)

  • 박범;윤성준;박성욱;박준홍
    • 한국분무공학회지
    • /
    • 제19권4호
    • /
    • pp.204-210
    • /
    • 2014
  • Experimental study was conducted to investigate the effect of EGR(exhaust gas recirculation) on engine noise using single cylinder combustion ignition engine. Under constant engine rotary speed of 1200 RPM, 8 mg fuel quantity was injected with 15, 18 and 21% of oxygen ratio and 1400 bar of injection pressure. Using the in-cylinder pressure data acquired by a piezoelectric transducer, the engine performance parameters were calculated. Radiated engine noise measured for 10 seconds was analyzed using spectral characteristics and sound quality metrics such as loudness, sharpness, roughness. From the obtained engine performance parameters and sound quality metrics, effect of oxygen ratio of the premixed air, start of injection timing on frequency characteristic and sound quality metrics were analyzed. Correlation analysis was conducted between MPRR(maximum pressure rise rate), RI(ringing intensity) and sound quality metrics. RI was identified as the most important factor having influence on the sound quality metrics.

Dynamic Characteristics of an Unsteady Flow Through a Vortex Tube

  • Kim, Chang-Soo;Sohn, Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2209-2217
    • /
    • 2006
  • Dynamic flow characteristics of a counter-flow vortex tube is investigated using hot-wire and piezoelectric transducer (PZT) measurements. The experimental study is conducted over a range of cold air outlet ratios (Y=0.3, 0.5, 0.7, and 1.0) and inlet pressure 0.15 MPa. Temperatures are measured at the cold air outlet and along the vortex tube wall. Hot-wire is located at cold outlet and PZT is installed at inner vortex tube by mounting at throttle valve. The cold outlet temperature results show that the swirl flow of vortex tube is not axisymmetric. The hot-wire and PZT results show that there exist two distinct kinds of frequency, low frequency periodic fluctuations and high frequency periodic fluctuations. It is found that the low frequency fluctuation is consistent with the Helmholtz frequency and the high frequency fluctuation is strongly related with precession oscillation.