• Title/Summary/Keyword: Pickup Device

Search Result 42, Processing Time 0.02 seconds

Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices (SQUID를 이용한 뇌 청각유발 자장의 측정)

  • 이용호;권혁찬;김진목;박용기
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.421-428
    • /
    • 1997
  • Magnetic field sensors made from superconducting quantum interference device (SQUID) are the most sensitive low-frequency sensors available, enabling measurements of extremely weak magnetic fields from the brain. Neuromagnetic measurements allow superior spatial resolution, compared with the present electric measurements, and superior temporal resolution, compared with the fMRl and PET, providing useful informations for the functional diagnoses of the brain. We developed a 4-channel SQUID system for neuromagnetic applications. The main features of the system are its simple readout electronics and compact pickup coil structure. A magnetically shielded room has been constructed for the reduction of environmental magnetic noises. The developed SQUID system has noise level lower than the magnetic noise from the brain. Magnetic field signals of the spontaneous r-rhythm activity and auditory evoked magnetic fields have been measured.

  • PDF

A Study on the Behavior of a Spinning Flexible Disk near a Curved Wall (곡률이 있는 벽면근처에서 고속회전하는 유연디스크의 거동 해석)

  • Lee, Ho-Ryul;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.201-207
    • /
    • 2006
  • Information storage devices have been studied to increase the storage capacity and the data transfer rate as well as to decrease the access time and their physical sizes. Optical information storage devices have been achieved high-capacity by reducing optical spot size remarkably due to the development of Blue-ray technology. Optical information storage devices usually use 1.2mm-thick polycarbonate(PC) media to get high enough stiffness. However, it would be better if we can decrease the thickness of a disk for achieving thinner device while keeping the capacity as large as possible. Decreasing the thickness of the storage media makes it difficult to read and write data because it increases the transverse vibration of the rotating disk due to the interaction with surrounding air and the vibration characteristics of thin flexible disk itself, Therefore, a special design based on the fluid mechanics is required to suppress the transverse vibration of the disk in non-contact manner so that the optical pickup can read/write data successfully. In this study, a curved wall is proposed as a stabilizer to suppress the transverse vibration of a $95{\mu}m$-thick PC disk. The characteristics of disk vibration due to a curved wall have been studied through numerical and experimental analysis from the fluid mechanics point of view. The proposed shapes are possible candidates as stabilizers to suppress the transverse vibration of a flexible disk which rotates at high speed.

  • PDF

The analysis design and operating characteristics of VCM actuator for auto focusing (자동초점 조절용 VCM 액추에이터 구동특성 분석)

  • Park, J.M.;Lim, H.W.;Chae, B.;Kim, D.G.;Kim, P.H.;Cho, G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.447-448
    • /
    • 2007
  • Product development is consisting by trend that accommodate almost function digital cam in camera phone that can speak of Mobile appliance, and competition about number of elemental area of image sensor is consisting for market prior occupation between these. Propose in this research and small size camera phone self-focusing adjustment actuator that do city manufacture is similar with general storehouse pickup actuator drive way, but selected in cylindrical to reduce space that lens holder occupies because there is restriction loading of lens and space enemy. Target number of research established that execute drive displacement more than $600{\mu}m$ in 2.75V that is house voltage that is used in Mobile device that is general. Also, described about maximum transfer displacement characteristic, displacement response characteristic, hysteresis, response characteristic, smallest transfer step characteristic, actuator's drive characteristic that is manufactured to examination item of maximum consumption electric power by special quality estimation system that apply laser displacement sensor that produce itself to evaluate city manufactured actuator's special quality.

  • PDF

Taguchi Robust Design of Tracked Vehicle for Manganese Nodule Test Miner in Collecting Operation Considering Deep-sea Noise Factors (심해 잡음인자를 고려한 망간단괴 시험집광기의 채집운용시 주행장치 다구치 강건설계)

  • Cho, Su-Gil;Lee, Min-Uk;Lim, Woo-Chul;Choi, Jong-Su;Kim, Hyung-Woo;Lee, Chang-Ho;Hong, Sup;Lee, Tae-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • A deep-sea manganese nodule miner consists of 4 parts: the pickup device, crusher, disposal device, and tracked vehicle. The tracked vehicle is an essential component to keep the self-propelled miner moving across deep-sea soil. The performances of the tracked vehicle are influenced by noise factors: the shear strength of the seafloor, bottom current, seafloor slope, track speed, reaction forces of flexible hose, etc. It is necessary to adopt a robust design method that improves the performances and minimizes the variation caused by noise factors. Taguchi's method, the most widely known robust design method, searches for the robust optimum using an orthogonal array composed of the product of the inner array and outer array. In this paper, we propose a new screening technique to reduce the number of input factors and apply the MRSN (Multi-Response Signal to Noise) ratio to convert multiple performances into single one in order to overcome the difficulties and limitations of using Taguchi's method in a case with many input factors and multiple performances. A test miner was already designed and tested. It has about 1/10 the capacity of a commercial one and was successfully operated at an in-shore area. Taguchi's robust design was applied to the tracked vehicle of the test miner, and design improvements were implemented for the vehicle.

Fabrication of λ/2 Phase Plates for Optical Pickup Using a Proton Exchanged LiNbO$_{3}$ (양자 교환된 리튬나오베이트를 이용한 광 픽업용 λ/2 파장판 제작)

  • Son, Gyeong-Rak;Kim, Gwang-Taek;Kim, Yeong-Jo;Song, Jae-Won;Park, Gyeong-Chan;Kim, Jin-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.4
    • /
    • pp.38-44
    • /
    • 2000
  • In this paper, we have been fabricated λ/2 phase plates lot an optical pick-up using a blue violet laser diode by employing proton exchange and wet etching in LiNbO$_{3}$. Their functions and fabrication processes are described in detail. It is established the optimal fabrication conditions through the experimental results. The device characteristics are measured by the Mach-zender interferometer which is composed of the optical components and 632.8nm He-Ne laser. The measured phase error was +5$^{\circ}$~ -6$^{\circ}$(within 3%). This phase plate could be applied an useful device to improve the resolution and the stability of the optical pick-up which has a blue violet laser diode as an optical source.

  • PDF

Construction and Operation of a 37-channel Hemispherical Magnetoencephalogram System (37채널 반구형 뇌자도 측정장치 제작 및 동작)

  • 이용호;김진목;권혁찬;김기웅;박용기;강찬석;이순걸
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.159-165
    • /
    • 2003
  • We developed a 37-channel magnetoencephalogram (MEG) measurement system based on low-noise superconducting quantum interference device (SQUID) magnetometets, and operated the system to measure MEG signals. By using double relaxation oscillation SQUIDs with high flux-4o-voltage transfers, the SQUID outputs could be measured directly by room temperature preamplifiers and compact readout circuits were used for SQUID operation. The average field noise level of the magnetometers is about 3 fT/√Hz in the white region, low enough for MEG measurements when operated inside a magnetically shielded room. The 37 magnetometers were distributed on a hemispherical surface haying a radius of 125 mm. In addition to the 37 sensing channels. 11 reference channels were installed to pickup external noise and to form software gradiometers. A low-noise liquid helium dewar was fabricated with a liquid capacity of 30 L and boil-off rate of 4 L/d. The signal processing software consists of digital filtering, software gradiometer, isofield mapping and source localization. By using the developed system, we measured auditory-evoked fields and localized the current dipoles, demonstrating the effectiveness of the system.

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

Measurement and Assessment on the Shaft Power Measurement of Diesel Engine using Strain Gauge in Marine Vessel (선박에서 스트레인 게이지를 이용한 디젤엔진의 축 동력 측정과 평가)

  • Lee, Don-Chool;Song, Myong-Ho;Kim, Sang-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1152-1161
    • /
    • 2009
  • The power measurement of main propulsion system on the new vessels can be classified with the direct method acquired from the shaft's strain using strain gauge and the indirect method converted and summed from all of cylinders combustion pressure using mechanical or electrical pickup device during the sea trial. This power is fluctuated by external factors which was influenced by various sea motions with long time interval and by internal factors which was influenced by varying torques of torsional vibration and bending moment, due to mis-aligned shaft and whirling vibration with short time interval. In this paper, the statistical analysis method for the shaft power measurement and assessment using strain gauge in marine vessels are introduced. And these are identified by the low speed two stroke diesel engine model and four stroke medium speed diesel engine model including reduction gear.

Measurement of fMCG Signals using an Axial Type First-Order SQUID Gradiometer System (권선형 1차 미분계를 이용한 태아심자도 신호 측정)

  • Yu, K.K.;Kim, K.;Kang, C.S.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.139-143
    • /
    • 2009
  • We have fabricated a low-noise 61-channel axial-type first-order gradiometer system for measuring fetal magnetocardiography(MCG) signals. Superconducting quantum interference device(SQUID) sensor was based on double relaxation oscillation SQUID(DROS) for detecting biomagnetic signal, such as MCG, magnetoencphalogram(MEG) and fetal-MCG. The SQUID sensor detected axial component of fetal MCG signal. The pickup coil of SQUID sensor was wound with 120 ${\mu}m$ NbTi wire on bobbin(20 mm diameter) and was a first-order gradiometer to reject the environment noise. The sensors have low white noise of 3 $fT/Hz^{1/2}$ at 100 Hz on average. The fetal MCG was measured from $24{\sim}36$ weeks fetus in a magnetically shielded room(MSR) with shielding factor of 35 dB at 0.1 Hz and 80 dB at 100 Hz(comparatively mild shielding). The MCG signal contained maternal and fetal MCG. Fetal MCG could be distinguished relatively easily from maternal MCG by using independent component analysis(ICA) filter. In addition, we could observe T peak as well as QRS wave, respectively. It will be useful in detecting fetal cardiac diseases.

  • PDF

Review of Magnetocardiography Technology based on SQUIDs (SQUID를 이용한 심자도 기술의 개발동향)

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Kim, K.;Yu, K.K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.