• Title/Summary/Keyword: Picker

Search Result 50, Processing Time 0.02 seconds

Vibration Analysis on the Inspection Equipment Frame of a Semiconductor Test Handler Picker (반도체 테스트 핸들러 픽커 검사장비 프레임에 대한 진동해석)

  • Kim, Young-Choon;Kim, Young-Jin;Kook, Jeong-Han;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4815-4820
    • /
    • 2014
  • As semiconductor chips are on a small scale, large content and high integratation, it is essential to develop the device of pick and place at the system of the semiconductor test handler to ensure its high precision and durability. In this study, inspection equipment frame model of a semiconductor test handler picker was investigated by vibration analysis with the property of the natural frequency and harmonic response. As 3 kinds of analysis case models, the device of pick and place was located at the left side (Case 1), the center (Case 2) and the right side (Case 3) of the upper guideline. The range of natural frequencies until the 6th order on this frame model ranges from 80Hz to 500Hz. As the analysis of the harmonic response when the frame is resonant, Case 2 showed the maximum equivalent stress of 52.802 MPa more than Cases 1 or 3. Case 2 was the most intensive among the three cases. Using the analysis result of this study, the design of the frame model, which can be applied to the safe working environment of the system is believed to be possible.

A Statistical Review on States Relating to Operation of Radiotherapy Equipments in Seoul National University Hospital (서울대학교병원의 방사선치료장비 운용 통계에 관한 고찰)

  • Park, Heung-Deuk;Kim, Wan-Sun;Ahn, Hee-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.21-30
    • /
    • 1994
  • To analyze the states of operation of radiotherapy facilities in the period from 1979 to 1992 and to get the base for efficient operation and maintenance of the radiotherapy facilities. Data on the records of annual number of patients operated by each facility; span of suspension of operation, the cost and span of repairing, and parts of oui-of-order in the period from 1979 to 1992 were analyzed. We made a comparative analysis of average annual number of patients, annual span of the suspension of operation, annual cost ratio of repair, span of repairing per break down, and total number of broken parts. We could get following annual number of patients(day), span of the suspension of span ($\%$)(day). annual cost ratio fo repair($\%$), span of repairing per break down(Min-Max, day), and number of broken parts from this analysis. 1. Cobalt unit (Picker C-9) : 10,389(43), 0.4(0.83) 0.07, 1hr-2, 3 2. Linac(Clinac 6/100) : 11,492(50), 4.0(9.57), 0.98, 1hr-30, 12 3. Linac(Clinac 18) : 9.115(44), 12.7(30.5), 3.54, 1hr-108. 41 4. Simulator(Picker Ther-X) : 2,017(9), 0.51(1.3), 0.24, 1hr-2, 7 5. RTP(Capentec Cap-plan) : 528(2), 0.4(0.93), - hrs, - The conclusion obtained from statistical analysis above are as follows. 1. The rate of operation of Cobalt unit($99.6\%$) was higher that of Linear Accelerators ($87.3\%$). The rates operation of Simulator and RTP computer were very close to that of Cobalt unit. 2. In order to raise up the working ratio of accelerator. it is desirable that we keep our engineer to learn a sufficient technical skill and the equipment agent to stock sufficient spare parts. 3. In order to maintain Linear Accelerator efficiently, it is desirable to have annually $2.3\%$ of the purchase price of equiment for repairing.

  • PDF

Differences in Patient Experience by Arrangement Type of Medical Tourism Facilitators (외국인환자 유치업자 유형별 환자경험의 차이)

  • Cho, Heeran J.;Jin, Ki Nam
    • Korea Journal of Hospital Management
    • /
    • v.26 no.2
    • /
    • pp.27-42
    • /
    • 2021
  • This study investigated the differences in patient experience by arrangement type of medical tourism facilitators(MTF) from the pre-visit to visit stages. Specifically, patient experiences from each stage with different service providers (MTFs and medical institutions) were measured: provision of information and respect for patient preferences as pre-visit experiences with the facilitators, communication and concierge services as visit experiences with the facilitators, and medical services as medical institution experiences. The scale to measure foreign patients' experiences was modified from the 'Picker in-patient questionnaire(PPE)' and the 'Picker patient experience questionnaire(PPE-15)'. Quantitative data were collected by conducting a self-administered questionnaire on 173 patients from China, Russia, Mongolia, and Kazakhstan. Qualitative data were collected by conducting in-depth interviews with 9 patients and 9 service providers. The data were collected between January and October in 2019. Quantitative data was analyzed by SPSS 25 for Chi-squared test and ANOVA, and qualitative data were analyzed based on keywords. The main results are as follows. When foreign patients used only overseas MTFs, they had a relatively positive patient experience in respect of receiving pre-visit information(F=7.47, p<.01) and respect for patient preferences(F=3.11, p<.05). Looking at both domestic and overseas facilitators during the visit, the patient experience was relatively negative for communication(F=3.75, p<.05). Regarding medical institutions, patients had a relatively negative patient experience with regards to medical services when they used both domestic and overseas facilitators(F=6.49, p<.01). The implications of this study are as follows. Patients should have a seamless and high-quality experience regardless of the facilitator arrangement type. This can be prepared through service standardization for the service providers. It would be also necessary to consider each other's features and problems at the institutional level and to improve service coordination by having service providers periodically communicate with each other.

DIAGNOSTIC ULTRASONOGRAPHY IN HEAD AND NECK REGION (두경부영역에서의 초음파촬영을 이용한 진단)

  • Cho, Byoung-Ouck;Lee, Yong-Chan;Koh, Back-Jin;Choi, Chang-Wan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.1
    • /
    • pp.96-102
    • /
    • 1990
  • Diagnostic ultrasound has the advantages of being noninvasive without any known deleterious biologic effect, rapid, painless, inexpensive and easily reproducible. The author used a real time sector scanner (Picker, Artis USA:5-7.5 MHz) for examing of lipoma, abscess, hematoma, lymphnode enlargement etc. and evaluated ultrasonograph as a diagnostic aid in head and neck region.

  • PDF

Pareto-Based Multi-Objective Optimization for Two-Block Class-Based Storage Warehouse Design

  • Sooksaksun, Natanaree
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.4
    • /
    • pp.331-338
    • /
    • 2012
  • This research proposes a Pareto-based multi-objective optimization approach to class-based storage warehouse design, considering a two-block warehouse that operates under the class-based storage policy in a low-level, picker-to-part and narrow aisle warehousing system. A mathematical model is formulated to determine the number of aisles, the length of aisle and the partial length of each pick aisle to allocate to each product class that minimizes the travel distance and maximizes the usable storage space. A solution approach based on multiple objective particle swarm optimization is proposed to find the Pareto front of the problems. Numerical examples are given to show how to apply the proposed algorithm. The results from the examples show that the proposed algorithm can provide design alternatives to conflicting warehouse design decisions.

Implementation of a Real-time SIFT Pitch Detector (실시간 SIFT 기본주파수 검출기의 구현)

  • Lee, Jong Seok;Lee, Sang Uk
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.101-113
    • /
    • 1986
  • In this paper, a real-time pitch detector LPC vocoder as implemented on a high speed digital signal processor, NEC 7720, is described. The pitch detector was based mainly on the SIFT algorithm. The SIFT pitch detector consists primarily of a digital low pass filter, inverse filter, computation of autocorrelation, a peak picker, interpolation, V/UV defcision and a final pitch smoother. In our approach, modification, mainly on the V/UV decision and a final pitch smoother, was made to estimate more accurate pitches. An 16-bit fixed-point aithmatic was employed for all necessary computation and the simulated results were compared with the eye detected pitches obtained from real speech data. The pitch detector occupies 98.8% of the instruction ROM, 37% of the data ROM, and 94% of internal RAM and takes 15.2ms to estimate a pitch when an analysis frame is consisted of 128 sampled speech data. It is observed that the tested results were well agreed with the computer simulation results.

  • PDF

Application of the Onsite EEW Technology Using the P-Wave of Seismic Records in Korea (국내 지진관측기록의 P파를 이용한 지진현장경보기술 적용)

  • Lee, HoJun;Jeon, Inchan;Seo, JeongBeom;Lee, JinKoo
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.133-143
    • /
    • 2020
  • Purpose: This study aims to derive a predictive empirical equation for PGV prediction from P-wave using earthquake records in Korea and to verify the reliability of Onsite EEW. Method: The noise of P wave is removed from the observations of 627 seismic events in Korea to derive an empirical equation with PGV on the base rock, and reliability of Onsite alarms is verified from comparing PGV's predictions and observations through simulation using the empirical equation. Result: P-waves were extracted using the Filter Picker from earthquake observation records that eliminated noises, a linear regression with PGV was used to derive a predictive empirical equation for Onsite EEW. Through the on-site warning simulation we could get a success rate of 80% within the MMI±1 error range above MMI IV or higher. Conclusion: Through this study, the design feasibility and performance of Onsite EEWS using domestic earthquake records were verified. In order to increase validity, additional medium-sized seismic observations from abroad are required, the mis-detection of P waves is controlled, and the effect of seismic amplification on the surface is required.

Evaluation of Chest Density in Insight Film (Insight film을 이용한 농도측정 평가)

  • Kwon, Lee-Seon;Park, Jang-Hwan;Lim, Oh-Soo;Jung, Kyong-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.17-23
    • /
    • 1992
  • Simple chest radiography is the most frequently performed examination in radiologic practice. However, with transmitted dose through chest which has the problem of wide variations in absorption, conventional Film/Screen Combinations Method make it difficult to delineate lung field mediastinum & cardia portion and subdiaphragmatic structures. In order to overcome this problem, we have been tried several methods as follows. High Kilovoltage Technique, Rare Earth Screen/Wide Lattitude Film, Use of Compensating Filter and Digital Beam Attenuator and recently Insigh System has been developed. In this paper, we'd like to discuss Insight film through apperciation by measuring the difference of contrast. In order to evaluate insight film. We have done experiments using Insight System with Simple Phase, Picker 550. We could get an result which was able to overcome the limitted dynamic range of conventional Film/Screen System remarkably.

  • PDF