• Title/Summary/Keyword: Physical protection

Search Result 725, Processing Time 0.027 seconds

Technology Trends in Spent Nuclear Fuel Cask and Dry Storage (사용후핵연료 운반용기 및 건식저장 기술 동향)

  • Shin, Jung Cheol;Yang, Jong Dae;Sung, Un Hak;Ryu, Sung Woo;Park, Yeong Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.110-116
    • /
    • 2020
  • As the management plan for domestic spent nuclear fuel is delayed, the storage of the operating nuclear power plant is approaching saturation, and the Kori 1 Unit that has reached its end of operation life is preparing for the dismantling plan. The first stage of dismantling is the transfer of spent nuclear fuel stored in storage at plants. The spent fuel management process leads to temporary storage, interim storage, reprocessing and permanent disposal. In this paper, the technical issues to be considered when transporting spent fuel in this process are summarized. The spent fuels are treated as high-level radioactive waste and strictly managed according to international regulations. A series of integrity tests are performed to demonstrate that spent fuel can be safely stored for decades in a dry environment before being transferred to an intermediate storage facility. The safety of spent fuel transport container must be demonstrated under normal transport conditions and virtual accident conditions. IAEA international standards are commonly applied to the design of transport containers, licensing regulations and transport regulations worldwide. In addition, each country operates a physical protection system to reduce and respond to the threat of radioactive terrorism.

Characterization of Peanut stunt virus Isolated from Black Locust Tree (Robinia pseudo-acacia L.)

  • Bang, Ju-Hee;Choi, Jang-Kyung;Lee, Sang-Yong
    • The Plant Pathology Journal
    • /
    • v.22 no.2
    • /
    • pp.125-130
    • /
    • 2006
  • An isolate of Peanut stunt virus (PSV) isolated from black locust tree (Robinia pseudo-acacia L.) showing severe mosaic and malformation symptoms, was designated as PSV-Rp. PSV-Rp was characterized by the tests of host range, physical properties, RNA and coat protein composition and RT-PCR analysis. Nucleotide sequences of the cucumoviruses CP genes were also used for identification and differentiation of PSV-Rp. Six plant species were used in the host range test of PSV-Rp. PSV-Rp could be differentiated from each Cucumovirus strain used as a control by symptoms of the plants. The physical properties of PSV-Rp virus were TIP $65^{\circ}C$, DEP $10^{-3}$, and LIP $2{\sim}3$ days. In dsRNA analysis, PSV-Rp consisted of four dsRNAs, but satellite RNA was not detected. Analysis of the coat proteins by SDS-PAGE showed one major protein band of about 31 kDa. RT-PCR using a part of Cucumovirus RNA3 specific primer amplified ${\sim}950bp$ DNA fragments from the crude sap of virus-infected black locust leaves. RFLP analysis of the RT-PCR product could differential PSV-RP from CMV The nucleotide sequence identity between the PSV-Rp CP and the TAV-P CP genes and the PS-V-RP CP and CMV-Y CP genes were 61.6% and 40.5%, respectively. On the other hand, the nucleotide sequence identity of the PSV-Rp CP gene was $70.9%{\sim}73.4%$ in comparison with those of PSV subgroup I (PSV-ER and PSV-J) and 67.3% with that of PSV subgroup II(PSV-W). Especially, the nucleotide sequence identity of PSV-Rp CP gene and that of PSV-Mi that was proposed recently as the type member of a novel PSV subgroup III was 92.4%.

An External Dose Assessment of Worker during RadWaste Treatment Facility Decommissioning

  • Chae, San;Park, Seungkook;Park, Jinho;Min, Sujung;Kim, Jongjin;Lee, Jinwoo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.81-87
    • /
    • 2020
  • Background: Kori unit #1 is permanently shut down after a 40-year lifetime. The Nuclear Safety and Security Commission recommends establishing initial decommissioning plans for all nuclear and radwaste treatment facilities. Therefore, the Korea Atomic Energy Research Institute (KAERI) must establish an initial and final decommissioning plan for radwaste-treatment facilities. Radiation safety assessment, which constitutes one chapter of the decommissioning plan, is important for establishing a decommissioning schedule, a strategy, and cost. It is also a critical issue for the government and public to understand. Materials and Methods: This study provides a method for assessing external radiation dose to workers during decommissioning. An external dose is calculated following each exposure scenario, decommissioning strategy, and working schedule. In this study, exposure dose is evaluated using the deterministic method. Physical characterization of the facility is obtained by both direct measurement and analysis of the drawings, and radiological characterization is analyzed using the annual report of KAERI, which measures the ambient dose every month. Results and Discussion: External doses are calculated at each stage of a decommissioning strategy and found to increase with each successive stage. The maximum external dose was evaluated to be 397.06 man-mSv when working in liquid-waste storage. To satisfy the regulations, working period and manpower must be managed. In this study, average and cumulative exposure doses were calculated for three cases, and the average exposure dose was found to be about 17 mSv/yr in all the cases. Conclusion: For the three cases presented, the average exposure dose is well below the annual maximum effective dose restriction imposed by the international and domestic regulations. Working period and manpower greatly affect the cost and entire decommissioning plan; hence, the chosen option must take account of these factors with due consideration of worker safety.

Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom (물리적 팬텀을 이용한 CT 촬영 환자의 피폭 선량 측정 및 평가)

  • Jang, Ki-Won;Lee, Choon-Sik;Kwon, Jung-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.113-119
    • /
    • 2005
  • The computed tomogrpahy(CT) provides a high quality in images of human body but contributes to the relatively high patient dose. The frequency of CT examination is increasing and, therefore, the concerns about the patient dose are also increasing. In this study the experimental determination of patient dose was performed by using a physical anthropomorphic phantom and thermoluminescent dosimeter(TLD). The measurements were done for the both axial and spiral scan mode. As a result the effective doses for each scan mode were 17.78mSv and 10.01 mSv respectively and the fact that the degree of the reduction in the patient dose depends on the pitch scan parameter was confirmed. The measurement methods suggested in this study can be applied for the reassessment of the patient dose when the technique in CT equipment is developed or the protocol for CT scanning is changed.

Studies on Wood Quality and Growth of Alnus glutinosa (L.) Gaertn. in Korea - Physical Properties - (글루티노사오리나무의 생장과 재질에 관한 연구 - 물리적 성질 -)

  • Han, Ju-Hwan;Jeong, Jae-Hun;Lee, Gooi-Yong;Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Relationship between annual ring width and physical properties of 24-year old alder woods (Alnus glutinosa L.) that had different seed origins from four provenances such as Bulgary, Italy, United Kindom, and Yugoslavia was investigated. No difference among different origins of seeds was found for the moisture content, density, and shrinkage or tangential radial (T/R) ratio. These properties had also no relationship with the growth rate. As important parameters among wood quality indices, no difference in the density or shrinkage on wood that has different growth rates was detected among alder woods from four different origins of seeds. Therefore, it is considered that higher growth rate might be a key factor for selecting the seed origin of the alder tree.

Analysis of Public Notice of NSSC and Field Application Case Regarding Security of Radioisotopes (원자력안전위원회 방사성동위원소 보안관련 고시 및 현장 적용 사례 분)

  • Lee, Hyun-Jin;Lee, Jin-Woo;Jeong, Gyo-Seong;Lee, Sang-bong;Kim, Chong-Yeal
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.303-310
    • /
    • 2018
  • Since Roentgen discovered X-rays, radiation sources have been utilized for many areas such as agriculture, industry, medicine and fundamental chemical research. As a result, human society has gained lots of benefits. However, if a radioactive material is used for the malicious purpose, it causes serious consequences to humanity and environment. Consequently, international organizations including International Atomic energy Agency (IAEA) have been emphasizing establishment and implementation of security management to prevent sabotage and illicit trafficking of radioactive materials. For this reason, the rule of technical standards of radiation safety management was revised and the public notice of security management regarding radioisotope was legislated in 2015 by Nuclear Safety and Security Commission (NSSC). Several radioactive sources which have to be regulated under the above rule and the public notice have been utilized in Advanced Radiation Technology Institute (ARTI) of Korea Atomic Energy Research Institute (KAERI). In order to control them properly, security management system such as access control and physical protection has been adapted since 2015. In this paper, we have analyzed the public notice of NSSC and its field application case. Based on the results, we are going to draw improvement on the public notice of NSSC and security system.

Study on Effectiveness of Accident Reduction Depending on Autonomous Emergency Braking System (AEB 장치에 대한 사고경감 효과 연구)

  • Choi, JunYoung;Kang, SeungSu;Park, EunAh;Lee, KangWon;Lee, SiHun;Cho, SooKang;Kwon, YoungGil
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.2
    • /
    • pp.6-10
    • /
    • 2019
  • This paper describes effectiveness of accident reduction on vehicles equipped with AEB using accident data occurring in Korea. During the statistical period, we used the number of vehicles which are covered by auto insurance and the number of accidents. To maximize the reduction effect of accidents caused by the driver's carelessness, the analysis was limited to Physical Damage Coverage that covers the cost of repairing or replacing the damaged vehicle caused by the driver's fault. Due to Personal Information Protection Law, it was not capable of comparing the same vehicle using Vehicle Identification Number in this study. Instead of that, we used it as a similar vehicle, so there are limits to the comparison and analysis results. As a result of this study, we have found that the effect of reducing accidents was different depending on the vehicle class, but it was generally concluded that the number of accidents decreased when the vehicle was equipped with an AEB system. Domestic research on the AEB effect of reducing accidents is not active yet. Therefore, it is absolutely essential to analyze the effects according to various conditions such as driver's age, occupation and gender as well as expanding the study models in the future.

Development and Validation of an Integrated Healthy Workplace Management Model in Taiwan

  • Fu-Li Chen;Peter Y. Chen;Chi-Chen Chen;Tao-Hsin Tung
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.394-400
    • /
    • 2022
  • Background: Impacts of exposure are generally monitored and recorded after injuries or illness occur. Yet, absence of conventional after-the-effect impacts (i.e., lagging indicators), tend to focus on physical health and injuries, and fail to inform if workers are not exposed to safety and health hazards. In contrast to lagging indicators, leading indicators are proactive, preventive, and predictive indexes that offer insights how effective safety and health. The present study is to validate an extended Voluntary Protection Programs (VPP) that consists of six leading indicators. Methods: Questionnaires were distributed to 13 organizations (response rate = 93.1%, 1,439 responses) in Taiwan. Cronbach α, multiple linear regression and canonical correlation were used to test the reliability of the extended Voluntary Protection Programs (VPP) which consists of six leading indicators (safe climate, transformational leadership, organizational justice, organizational support, hazard prevention and control, and training). Criteria-related validation strategy was applied to examine relationships of six leading indicators with six criteria (perceived health, burnout, depression, job satisfaction, job performance, and life satisfaction). Results: The results showed that the Cronbach's α of six leading indicators ranged from 0.87 to 0.92. The canonical correlation analysis indicated a positive correlation between the six leading indicators and criteria (1st canonical function: correlation = 0.647, square correlation = 0.419, p < 0.001). Conclusions: The present study validates the extended VPP framework that focuses on promoting safety and physical and mental health. Results further provides applications of the extended VPP framework to promote workers' safety and health.

A Review of the Physical Performance of Lightweight Aerated Concrete for Use as an Interior Core Material in Fire Doors (방화문 내부 심재로 적용하기 위한 경량기포콘크리트의 물리적 성능 검토)

  • Hong, Sang-Hun;Kim, Bong-Joo;Jung, Ui-In;Kim, Hae-Nah;Park, Jun-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.111-112
    • /
    • 2023
  • With the development of cities, the density of the population is continuously increasing as buildings become larger and more high-rise, but since the Haeundae residential complex fire in Busan in 2010, there has been a growing need to meet the fire protection performance of buildings as large-scale fires continue to occur every year. On the other hand, fire doors, which are one of the fire protection performance of buildings, have been judged unqualified in 82% of cases when fire doors constructed on the actual site were inspected after completion. The reason for this is that paper honeycomb and glasswool, which are used as core materials for fire doors, absorb moisture, reducing thermal insulation performance, and sagging due to increased weight, leading to performance degradation due to warping in empty spaces. To overcome these problems, research is underway to apply lightweight aerated concrete, an inorganic material, as a core material. Therefore, in order to select a blowing agent that produces stable bubbles prior to the production of lightweight bubble concrete for application as a fire door inner core, this study examined the physical performance according to the type of blowing agent and dilution concentration, and the following conclusions were drawn. Compared to vegetable bubbles and independent bubbles, synthetic bubbles have 3~8% higher thermal conductivity than independent bubbles, but 3~6% lower slurry density than vegetable bubbles, and 2~13% higher compressive strength, which is thought to be an improvement of synthetic bubbles.

  • PDF

A close look at the influence of praseodymium (III) oxide on the structural, physical, and γ-ray protection capacity of a ternary B2O3-PbO-CdO glass system

  • R.H. Shoeir;M. Afifi;Abdelghaffar S. Dhmees;M.I. Sayyed;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2258-2265
    • /
    • 2024
  • The present investigation aims to study the role of Pr2O3 on the structural, physical, and radiation shielding properties of a dense cadmium lead borate glass. The XRD was used to affirm the glassy amorphous structure of fabricated sample materials. Moreover, the FTIR was used to record the change in the FT-IR spectra due to the addition of Pr2O3 in the wavenumber interval between 400 and 4000 cm-1. The features of glass surfaces and the elemental analyses for the synthesized Pr2O3-reinforced cadmium lead borate glasses were performed using a SEM, supported by an energy-dispersive spectrometer. The γ-ray protection capacity was evaluated using the Monte Carlo method in a wide energy interval ranging between 0.015 and 15 MeV. The linear attenuation coefficient (LAC) at 1 MeV was reduced by a factor of 10 % from 0.372 cm-1 to 0.340 cm-1. The decrease in the LAC values negatively affected the other shielding properties such as half-value thickness and the transmission factor. Although the linear attenuation coefficient is decreased slightly with the partial substitution of CdO by Pr2O3 compound, the fabricated glass samples still have a high shielding capacity compared to the traditional commercial glasses as well as previous similar reported glasses.