• Title/Summary/Keyword: Physical Protection

Search Result 725, Processing Time 0.033 seconds

개인정보 손해배상책임 보장제도의 쟁점과 과제 (Issues and Tasks of Personal Information Protection Liability Insurance)

  • 이수연;권헌영
    • 한국IT서비스학회지
    • /
    • 제19권1호
    • /
    • pp.37-53
    • /
    • 2020
  • Today, our society is exposed to cyber threats, such as the leakage of personal information, as various systems are connected and operated organically with the development of information and communication technology. With the impact of these cyber risks, we are experiencing damage from the virtual world to the physical world. As the number of cases of damage caused by cyber attacks has continued to rise, social voices have risen that the government needs to manage cyber risks. Thus, information and telecommunication service providers are now mandatory to have insurance against personal information protection due to amendment of "the Act on Promotion of Information and Communication Network Utilization and Information Protection". However, the insurance management system has not been properly prepared, with information and communication service providers selecting the service operators based on sales volume rather than selecting them based on the type and amount of personal information they store and manage. In order for the personal information protection liability insurance system to be used more effectively in line with the legislative purpose, effective countermeasures such as cooperation with the government and related organizations and provision of benefits for insured companies should be prepared. Thus, the author of this study discuss the current status of personal information protection liability insurance system and the issues raised in the operation of the system. Based on the results of this analysis, the authors propsoe tasks and plans to establish an effective personal information protection liability insurance system.

호텔건축물의 방화안전대책에 관한 연구 (A Study on the Safety Measures of Fire Protection in Hotel Buildings)

  • 안태용;이영재
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.80-90
    • /
    • 2001
  • 호텔 건축물은 현대적 기능요구에 따라 대규모화, 고급화, 복합용도화 될 것으로 예상된다. 또한 건물 이용자는 불특정 다수인으로 그 건물에 대한 정보가 부족하기 때문에 화재시 인명 피해가 우려된다. 그러므로 이러한 문제점을 극복하기 위하여 호텔 건축물에는 화재·피난안전상 유의하여야 할 사항에 대하여 체계적인 방화시설이 요구된다. 본 연구에서는 첫째, 호텔의 이용실적조사, 화재관련통계, 화재사례조사, 방화의식 조사를 하였으며, 둘째, 호텔 건축물의 건축계획적인 사항을 검토하였으며, 셋째, 방재시설에 관한 법규정을 분석한 후 제안하였다. 이 연구의 목적은 화재시 인간 및 재산의 보호와 그 피해를 최소화할 수 있는 호텔 공간을 건축하는데 기초적인 자료를 제시하는 것이다.

  • PDF

Disparities in Workplace Hazards and Organizational Protection Resources by Enterprise Size: A National Representative Study of South Korean Manufacturing Workers

  • Hye-Lin Lee;Ji-Hwan Kim;Taesun Kang;Garin Lee;Hayoung Lee;Hee Won Kim;Seung-Sup Kim
    • Safety and Health at Work
    • /
    • 제15권3호
    • /
    • pp.284-291
    • /
    • 2024
  • Background: This study aimed to identify the prevalence of workplace hazards and organizational protection resources according to the size of the enterprise in the manufacturing industry of the Republic of Korea. Methods: We analyzed data of waged workers (weighted N = 5,879) from the Fifth Korean Working Conditions Survey (2017). Enterprise sizes were categorized as "micro enterprises" (less than five employees), "small enterprises" (5-49 employees) and "medium-large enterprises" (50 or more employees). Self-reported exposure to 18 physical, chemical, ergonomic, and psychological hazards were measured. The presence of organizational protection resources such as a labor union, a safety delegate working at the company, designated spaces to deal with safety, and the provision of health and safety information was evaluated. Results: Compared to workers in medium-large enterprises, those in micro enterprises showed a higher proportion of exposure to most of physical, chemical, ergonomic, and psychological hazards, except for exposure to solvents, prolonged sitting, and experiencing a state of emotional unrest. On the other hand, workers in micro enterprises had the lowest proportion of access to organizational protection resources. Conclusion: Our study demonstrates that manufacturing workers at the micro enterprise in the Republic of Korea are exposed to the most hazardous work environment and yet have access to the fewest organizational protection resources.

SystemC를 이용한 OpenCableTM Copy Protection Module의 Physical Layer 설계 (A Design Of Physical Layer For OpenCable Copy Protection Module Using SystemC)

  • 이정호;이숙윤;조준동
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2004년도 춘계학술발표대회
    • /
    • pp.157-160
    • /
    • 2004
  • 본 논문은 미국 차세대 디지털 케이블 방송 표준 규격인 오픈케이블($OpenCable^{TM}$)의 수신제한 모듈인 CableCard의 Physical Layer를 SystemC의 TLM(Transaction Level Modeling)과 RTL(Register-Transfer Level) 모델링 기법으로 설계하였다. 본 논문에서 설계한 CableCard의 Physical Layer는 PCMCIA Interface, Command Inteface 그리고 MPEG-2 TS Interface 로 구성된다. CableCard가 전원이 인가될 때, 카드 초기화를 위하여 동작하는 PCMCIA 인터페이스는 16 비트 PC 카드 SRAM 타입으로 2MByte Memory와 100ns access time으로 동작할 수 있게 설계하였다. PCMCIA 카드 초기화 동작이 완료된 후, CableCard의 기능을 수행하기 위하여 두 개의 논리적 인터페이스가 정의되는데 하나는 MPEG-2 TS 인터페이스이고, 다른 하나는 호스트(셋톱박스)와 모듈 사이의 명령어들을 전달하는 명령어 인터페이스(Command Interface)이다. 명령어 인터페이스(Command Interface)는 셋톱박스의 CPU와 통신하기 위한 1KByte의 Data Channel과 OOB(Out-Of-Band) 통신을 위한 4KByte의 Extended Channel 로 구성되고, 최대 20Mbits/s까지 동작한다. 그리고 MPEG-2 TS는 100Mbits/s까지 동작을 수행할 수 있게 설계하였다. 설계한 코드를 실행한 후, Cadence사의 SimVision을 통해서 타이밍 시뮬레이션을 검증하였다.

  • PDF

Physical protection system vulnerability assessment of a small nuclear research reactor due to TNT-shaped charge impact on its reinforced concrete wall

  • Moo, Jee Hoon;Chirayath, Sunil S.;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2135-2146
    • /
    • 2022
  • A nuclear energy facility is one of the most critical facilities to be safely protected during and after operation because the physical destruction of its barriers by an external attack could release radioactivity into the environment and can cause harmful effects. The barrier walls of nuclear energy facilities should be sufficiently robust to protect essential facilities from external attack or sabotage. Physical protection system (PPS) vulnerability assessment of a typical small nuclear research reactor was carried out by simulating an external attack with a tri-nitro toluene (TNT) shaped charge and results are presented. The reinforced concrete (RC) barrier wall of the research reactor located at a distance of 50 m from a TNT-shaped charge was the target of external attack. For the purpose of the impact assessment of the RC barrier wall, a finite element method (FEM) is utilized to simulate the destruction condition. The study results showed that a hole-size of diameter 342 mm at the front side and 364 mm at the back side was created on the RC barrier wall as a result of a 143.35 kg TNT-shaped charge. This aperture would be large enough to let at least one person can pass through at a time. For the purpose of the PPS vulnerability assessment, an Estimate of Adversary Sequence Interruption (EASI) model was used, which enabled the determination of most vulnerable path to the target with a probability of interruption equal to 0.43. The study showed that the RC barrier wall is vulnerable to a TNT-shaped charge impact, which could in turn reduce the effectiveness of the PPS.

높이 20미터 미만인 구조물의 낙뢰리스크 평가 (Lightning Risk Assessment for Structures Lower than 20m High)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.

Review for the Curriculum and License Exam of Physical Therapists in the United States

  • Choi, Chi-Whan;Jeong, Yeon-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • 제31권4호
    • /
    • pp.184-192
    • /
    • 2019
  • Purpose: This study was conducted to review the curriculum and license examination of physical therapists in the United States. Methods: The doctor of physical therapy (DPT) curriculum was evaluated by a review Course Work Tool version 6 (CWT6) data and current physical therapy licensure examination (National Physical Therapy Exam, NPTE) category in the United States. Results: The results indicated that they were required to meet the doctor of physical therapist degree based on 'Guide to Physical Therapist Practice' of American Physical Therapy Association (APTA). This includes general education in the areas of communications and humanities, physical science, biological science, social and behavioral science, and mathematics. A minimum of one course must be completed successfully in each area of general education. Moreover, there should be at least 68 didactic credits of professional education and 22 clinical education credits, which is a minimum of two full-time clinical internships with no less than 1050 hours in total, which were supervised by a physical therapist. Regarding the physical therapy licensure examination, National Physical Therapy Exam (NPTE, 2016) consisted of a physical therapy examination (26.5%), evaluation, differential diagnosis, baseline of prognosis (32.5%), intervention (28.5%), protection, responsibility, and research (6.5%) based on the 'Guide to Physical Therapist Practice'. Conclusion: Based on the study results provided above, it is considered a standard to meet domestic reality as the Guide to Physical Therapist Practice of APTA for South Korean physical therapists.

Twenty-Five Years of Physical Punishment Research: What Have We Learned?

  • Durrant, Joan E.;Ensom, Ron
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제28권1호
    • /
    • pp.20-24
    • /
    • 2017
  • Over the past quarter century, research on physical punishment has proliferated. Almost without exception, these studies have identified physical punishment as a risk factor in children's behavioral, emotional, cognitive and brain development. At the same time, the United Nations has established that physical punishment constitutes a breach of children's basic human rights to protection and dignity. Together, research findings and human rights standards have propelled profound global change. To date, 51 countries have prohibited all physical punishment of children. In this article, we review the literature on physical punishment within its historical context, and provide recommendations for health professionals working with families.

Al합금과 Ti합금의 방탄특성에 관한 실험적 연구 (An Experimental Study on the Characters of Bullet Proof for Al and Ti Alloy)

  • 손세원
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.113-120
    • /
    • 2005
  • In order to investigate the characteristics of penatration and the effect of surface treatment in A15052-H34, Al5082-Hl31 and titanium alloy laminates which were treated by anodizing and PVD(Physical Vapor Desposition) method, ballistic tests were conducted. Thickness of surface membrane in A15052-H34, Al5082-Hl31, were $25{\mu}m$ and that of titanium $0.9{\mu}m$ respectively. Surface hardness test was conducted using micro Vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit(V50), a statistical velocity with $50\%$ probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are observed from the results of V50 test and Projectile Through Plate(PTP) test at velocities greater than protection ballistic limit, respectively. Present experimental results derived from this research help to optimize laminate impact behavior by varing the laminate thickness and surface treated materials.