• Title/Summary/Keyword: Physical Compatibility

Search Result 149, Processing Time 0.023 seconds

Reduction of Leakage Current and Enhancement of Dielectric Properties of Rutile-TiO2 Film Deposited by Plasma-Enhanced Atomic Lay er Deposition

  • Su Min Eun;Ji Hyeon Hwang;Byung Joon Choi
    • Korean Journal of Materials Research
    • /
    • v.34 no.6
    • /
    • pp.283-290
    • /
    • 2024
  • The aggressive scaling of dynamic random-access memory capacitors has increased the need to maintain high capacitance despite the limited physical thickness of electrodes and dielectrics. This makes it essential to use high-k dielectric materials. TiO2 has a large dielectric constant, ranging from 30~75 in the anatase phase to 90~170 in rutile phase. However, it has significant leakage current due to low energy barriers for electron conduction, which is a critical drawback. Suppressing the leakage current while scaling to achieve an equivalent oxide thickness (EOT) below 0.5 nm is necessary to control the influence of interlayers on capacitor performance. For this, Pt and Ru, with their high work function, can be used instead of a conventional TiN substrate to increase the Schottky barrier height. Additionally, forming rutile-TiO2 on RuO2 with excellent lattice compatibility by epitaxial growth can minimize leakage current. Furthermore, plasma-enhanced atomic layer deposition (PEALD) can be used to deposit a uniform thin film with high density and low defects at low temperatures, to reduce the impact of interfacial reactions on electrical properties at high temperatures. In this study, TiO2 was deposited using PEALD, using substrates of Pt and Ru treated with rapid thermal annealing at 500 and 600 ℃, to compare structural, chemical, and electrical characteristics with reference to a TiN substrate. As a result, leakage current was suppressed to around 10-6 A/cm2 at 1 V, and an EOT at the 0.5 nm level was achieved.

Measures of Work-life Balance and Interventions of Reasonable Accommodations for the Return to Work of Cancer Survivors: A Scoping Review

  • Giuliana Buresti;Bruna Maria Rondinone;Antonio Valenti;Fabio Boccuni;Grazia Fortuna;Sergio Iavicoli;Maria Cristina Dentici;Benedetta Persechino
    • Safety and Health at Work
    • /
    • v.15 no.3
    • /
    • pp.255-262
    • /
    • 2024
  • Background: Nearly half of patients diagnosed with cancer are in the middle of their traditional working age. The return to work after cancer entails challenges because of the cancer or treatments and associated with the workplace. The study aimed at providing more insight into the occupational outcomes encountered by workers with cancer and to provide interventions, programs, and practices to support their return to work. Methods: A scoping review was conducted using the Arksey and O'Malley framework and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses for scoping review guidelines. Relevant studies were systematically searched in PubMed/MEDLINE, SCOPUS and Grey literature from 01 January 2000 to 22 February 2024. Results: The literature search generated 3,017 articles; 53 studies were considered eligible for this review. Most of the studies were longitudinal and conducted in Europe. Three macroarea were identified: studies on the impact of cancer on workers in terms of sick leave, employment, return to work, etc.; studies reporting wider issues that may affect workers, such as the compatibility of treatment and work and employment; studies reporting interventions or policies aiming to promote the return to work. Conclusion: There is a lack in the literature in defining multidisciplinary interventions combining physical, psycho-behavioural, educational, and vocational components that could increase the return-to-work rates. Future studies should focus on interdisciplinary return to work efforts with multiple stakeholders with the involvement of an interdisciplinary teamwork (healthcare workers and employers) to combine these multidisciplinary interventions at the beginning of sick leave period.

Comparison of Cleaning Performance of CFC 113 and the Alternatives (CFC 113과 대체세정제의 세정성능 비교)

  • Row, Kyung Ho;Choi, Dai-Ki;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.521-530
    • /
    • 1993
  • According to the Montreal Protocol, CFC 113, one of the ozone-depleting substances, will be prohibited to use as a cleaning solvent essentially in the electronic industry. Therefore, the development of the alternative cleaning solvents to CFC 113 is being accelerated. A number of the alternative cleaning solvents are avialable on the market. The alternatives of Axarel 32(DuPont), Cleanthru 750H(KAO Chemical), and EC-Ultra(Petroferm) are chosen for the comparison of cleaning performance with CFC 113. The test methods for measuring the cleaning performance were composed of the measurement of the physical properties, the experiments on the material compatibility with cleaning solvents, the measurement of the evaporation rate, and finally the experiments of the removal efficiency. Normally the basic physical properties of the alternatives had higher boiling points, viscosity and surface tension, which were quite different to those of CFC 113. In terms of solubility of rosin-based flux, the solubilities of abietic acid (nonpolar organic) were similar, but those of the activator (polar organic) in the alternatives were better than CFC 113. The evaporation of the alternatives was very slow, compared to CFC 113, which had much lower boiling point. All the cleaning solvents showed the good material compatibility with FR4 and Cu-coated PCB. The better removal efficiencies of abietic acid were obtained when using the ultrasonic mechanical energy over the dipping method. The experiments also indicated the very slow-eavaporating solvent was not desirable with the dipping cleaning method, and the differences in the removal efficiency of the alternatives with the ultrasonic cleaning method were negligible. Among the alternatives, the overall cleaning performances were obsorved as almost similar. Before selecting the ultimate cleaning solvent, the application of cleaning machine, environmental issues, and economics are simultaneously considered with the cleaning performance.

  • PDF

A Study on the standardization of ETCS (Focused on RF) (자동요금징수시스템(ETCS) 표준화 연구(주파수방식을 중심으로))

  • Kwon, Han-Joon;Lee, Ki-Hyun;Kim, Yong-Deak
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.3
    • /
    • pp.62-73
    • /
    • 2008
  • In this paper, domestic standard revision plan of dynamic frequency method which is used both in unmanned automatic toll collection system and manned collection system of the express highway is presented. For such ETCS, the infrared rays (870 nm) of active frequency method and the frequency integrated method (5.8 GHz) are adopted and extended to be operated to the all around the Toll Gate. This standardization plan is based on inter connection reference model between OSI (Open System Interconnection) in process of ITS short range radio communication standardization of 5.8 GHz bandwidth to support traffic information and control system service, and the derived revision plan by starting from physical layer which support interoperability for multiple access between RSE (Road Side Equipment) and OBE (On Board Equipment), in which is categorized into physical layer, data link layer, and application layer. In case of radiation power, existing standard is divided by class1 (within 10 m) and Class2 (within 100 m) according to transmission lengthwhile it is operated with just single standard 'Class1' because of notification of Ministry of Information and Communication in 2004. In the case of the limitation value of incident power in communication area, considering operation plan of ETCS that is on actuality operation the measurements are reflected to the standard. In other wort this paper proposed the improvement standard of incident power, pseudo response in the communication area and radiated power in order to secure stability and compatibility among operator systems about the needed part on ETCS operation.

  • PDF

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

Effect of the Compatibilizer on Physical Properties of Polypropylene (PP)/Bamboo Fiber (BF) Composites (폴리프로필렌/대나무 섬유 복합체의 물성에 대한 상용화제의 영향)

  • Lee, Jong Won;Ku, Sun Gyo;Lee, Beom Hee;Lee, Ki-Woong;Kim, Cheol Woo;Kim, Ki Sung;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.615-620
    • /
    • 2015
  • Polypropylene (PP)/bamboo fiber (BF) composites were fabricated by twin screw extruder in order to investigate effects of the compatibilizer on physical properties of PP/BF composites. The content of BF changed from 10 to 25 wt% and that of the compatibilizer was fixed at 3 wt%. Maleic anhydride grafted PP (PP-g-MAH) was used to increase the compatibility between PP and BF as a compatibilizer. Chemical structures of the composites were confirmed by the existence of carbonyl group (C=O) stretching peak at $1,700cm^{-1}$ in FT-IR spectrum. Considering the degradation and mechanical properties, the optimum extrusion conditions were selected to be $210^{\circ}C$ and 100 rpm, respectively. There was no distinct changes in melting temperature of the composites, but the crystallization temperature increased by $10-20^{\circ}C$ owing to the heterogeneous nuclei of BF. It was checked that the optimum BF content was in the range of 15-20 wt% from the results of tensile and flexural properties of the composites. The effect of the compatibilizer on mechanical properties was confirmed by SEM images of fractured surface and contact angles.

Considerations on a Transportation Simulation Design Responding to Future Driving (미래 교통환경 변화에 대응하는 교통 모의실험 모형 설계 방향)

  • Kim, Hyoungsoo;Park, Bumjin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.6
    • /
    • pp.60-68
    • /
    • 2015
  • Recent proliferation of advanced technologies such as wireless communication, mobile, sensor technology and so on has caused significant changes in a traffic environment. Human beings, in particular drivers, as well as roads and vehicles were advanced on information, intelligence and automation thanks to those advanced technologies; Intelligent Transport Systems (ITS) and autonomous vehicles are the results of changes in a traffic environment. This study proposed considerations when designing a simulation model for future transportation environments, which are difficult to predict the change by means of advanced technologies. First of all, approximability, flexibility and scalability were defined as a macroscopic concept for a simulation model design. For actual similarity, calibration is one of the most important steps in simulation, and Physical layer and MAC layer should be considered for the implementation of the communication characteristics. Interface, such as API, for inserting the additional models of future traffic environments should be considered. A flexible design based on compatibility is more important rather than a massive structure with inherent many functions. Distributed computing with optimized H/W and S/W together is required for experimental scale. The results of this study are expected to be used to the design of future traffic simulation.

Effect of Adding Milk on Compatibility with 3D Printing in the Preparation of a Surimi Mixture (수리미 혼합물 제조 시 우유 첨가에 따른 3D 프린팅 적합성에 미치는 영향)

  • Yoo-Seok Kang;Hye-ji Hwang;Ye-Lin Park;Hyeon-Su Han;Jeong-Cheol Park;Hun-Seo Seo;Ye-Hui Choi;Su-Hyeong Kim;Ka-Eun Woo;So-Mi Jeong;Ga-Hye lee;Dong-Hyun Ahn
    • Journal of Life Science
    • /
    • v.33 no.5
    • /
    • pp.391-396
    • /
    • 2023
  • Milk is an emulsion, improving texture of surimi mixture and able to suppress off flavors and abnormal tastes. Therefore, this study aimed to identify the effective properties of milk in the preparation of a surimi mixture for 3D printing. The sensory and physical properties of surimi mixtures containing 0%, 20 wt%, and 40 wt% milk were evaluated, where the unheated surimi mixture with added milk demonstrated increased firmness and adhesiveness compared to the negative control group. In addition, the hardness, adhesiveness, gumminess, and chewiness of the mixture containing 40% milk were highest, but springiness, cohesiveness, and resilience were lowest. In the sensory evaluation, as the amount of milk increased, a fishy smell, abnormal taste and texture improved, hardness and preference increased as well. From these results, it was confirmed that a surimi mixture can be prepared with milk to improve its physical and sensory properties for 3D printing when compared to the negative control mixture. In particular, it was revealed that the physical properties and preference of the surimi mixture are best when prepared with 40% milk.

Development of the Information Delivery System for the Home Nursing Service (가정간호사업 운용을 위한 정보전달체계 개발 I (가정간호 데이터베이스 구축과 뇌졸중 환자의 가정간호 전산개발))

  • Park, J.H;Kim, M.J;Hong, K.J;Han, K.J;Park, S.A;Yung, S.N;Lee, I.S;Joh, H.;Bang, K.S
    • Journal of Home Health Care Nursing
    • /
    • v.4
    • /
    • pp.5-22
    • /
    • 1997
  • The purpose of the study was to development an information delivery system for the home nursing service, to demonstrate and to evaluate the efficiency of it. The period of research conduct was from September 1996 to August 31, 1997. At the 1st stage to achieve the purpose, Firstly Assessment tool for the patients with cerebral vascular disease who have the first priority of HNS among the patients with various health problems at home was developed through literature review. Secondly, after identification of patient nursing problem by the home care nurse with the assessment tool, the patient's classification system developed by Park (1988) that was 128 nursing activities under 6 categories was used to identify the home care nurse's activities of the patient with CAV at home. The research team had several workshops with 5 clinical nurse experts to refine it. At last 110 nursing activities under 11 categories for the patients with CVA were derived. At the second stage, algorithms were developed to connect 110 nursing activities with the patient nursing problems identified by assessment tool. The computerizing process of the algorithms is as follows: These algorithms are realized with the computer program by use of the software engineering technique. The development is made by the prototyping method, which is the requirement analysis of the software specifications. The basic features of the usability, compatibility, adaptability and maintainability are taken into consideration. Particular emphasis is given to the efficient construction of the database. To enhance the database efficiency and to establish the structural cohesion, the data field is categorized with the weight of relevance to the particular disease. This approach permits the easy adaptability when numerous diseases are applied in the future. In paralleled with this, the expandability and maintainability is stressed through out the program development, which leads to the modular concept. However since the disease to be applied is increased in number as the project progress and since they are interrelated and coupled each other, the expand ability as well as maintainability should be considered with a big priority. Furthermore, since the system is to be synthesized with other medical systems in the future, these properties are very important. The prototype developed in this project is to be evaluated through the stage of system testing. There are various evaluation metrics such as cohesion, coupling and adaptability so on. But unfortunately, direct measurement of these metrics are very difficult, and accordingly, analytical and quantitative evaluations are almost impossible. Therefore, instead of the analytical evaluation, the experimental evaluation is to be applied through the test run by various users. This system testing will provide the viewpoint analysis of the user's level, and the detail and additional requirement specifications arising from user's real situation will be feedback into the system modeling. Also. the degree of freedom of the input and output will be improved, and the hardware limitation will be investigated. Upon the refining, the prototype system will be used as a design template. and will be used to develop the more extensive system. In detail. the relevant modules will be developed for the various diseases, and the module will be integrated by the macroscopic design process focusing on the inter modularity, generality of the database. and compatibility with other systems. The Home care Evaluation System is comprised of three main modules of : (1) General information on a patient, (2) General health status of a patient, and (3) Cerebrovascular disease patient. The general health status module has five sub modules of physical measurement, vitality, nursing, pharmaceutical description and emotional/cognition ability. The CVA patient module is divided into ten sub modules such as subjective sense, consciousness, memory and language pattern so on. The typical sub modules are described in appendix 3.

  • PDF

Dependency of Compatibility Termination Criteria on Prehydration and Bentonite Quality for Geosynthetic Clay Liners (사전투수 및 벤토나이트 품질에 따른 GCL의 투수종결기준에 미치는 영향평가)

  • Lee Jae-Myung;Shackelford Charles D.;Choi Jae-Soon;Jung Moon-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.141-158
    • /
    • 2004
  • The dependency of criteria used to terminate compatibility tests on the prehydration and quality of bentonite in geosynthetic clay liners (GCLs) is evaluated based on permeation with chemical solutions containing 5, 10, 20, 50, and 100 mM calcium chloride ($CaCl_2$). The hydraulic conductivity tests are not terminated before chemical equilibrium between the effluent and the influent chemistry has been established, resulting in test durations ranging from < 1 day to > 900 days, with longer test durations associated with lower $CaCl_2$ concentrations. The evaluation includes both physical termination criteria (i.e., volumetric flow ratio and steady hydraulic conductivity based on ASTM D 5084, ${\ge}2$ pore volumes of flow, constant thickness of specimen) and chemical termination criteria requiring equilibrium between influent and effluent chemistry (viz., electrical conductivity, pH, and $Ca^{2+}\;and\;Cl^-$ concentrations). For specimens permeated with 5, 10, and 20 mM $CaCl_2$ solutions, only the criterion based on chemical equilibrium in $Ca^{2+}$ concentration correlates well with equilibrium in hydraulic conductivity, regardless of prehydration or quality of bentonite. However, all of the termination criteria, except for the volumetric flow ratio and 2 pore volumes of flow for the prehydrated specimens, correlate well with equilibrium in hydraulic conductivity regardless of prehydration or quality of bentonite when permeated with 50 and 100 mM $CaCl_2$ solutions. The results illustrate the uniqueness of the termination criterion based on solute concentration equilibrium between the effluent and the influent with respect to both prehydration and quality of bentonite in the GCLs.