• 제목/요약/키워드: Photovoltaic modules

검색결과 362건 처리시간 0.027초

고출력 슁글드 태양광 모듈 컬러 적용에 따른 출력 특성 분석 (Analysis of Power Characteristics of High-Power Shingled Photovoltaic Module with Color Application)

  • 김주휘;이재형
    • Current Photovoltaic Research
    • /
    • 제10권3호
    • /
    • pp.73-76
    • /
    • 2022
  • BIPV (Building Integrated Photovoltaic) supplemented the minimum area problem required when installing existing solar modules. However, in order to apply it to buildings, research was needed to increase the aesthetics of solar modules and use them as a design. Accordingly, modules with color applied to the entire surface of the photovoltaic module were being developed, but there was a disadvantage of low power. Therefore, by dividing and bonding the cell strips, it was possible to improve the output power by applying a shingled technology in which other divided cells overlap in a busbar region where light couldn't be received. Shingled technology was advantageous for color modules because the front busbar part that degrades aesthetics was removed. In this research, four color shingled solar modules (Green, Yellow, Blue, Gray) were manufactured and power degradation was analyzed by measuring transmittance and reflectance. Gray color had 80.83% transmittance, which was 31.31% higher than Yellow, resulting in a power difference of 4.45 W.

태양전지 모듈의 신뢰성 평가 (Reliability Evaluation for Photovoltaic Modules)

  • ;김근수
    • 마이크로전자및패키징학회지
    • /
    • 제19권2호
    • /
    • pp.1-5
    • /
    • 2012
  • Long-term reliability of Si photovoltaic modules is a crucial issue for the cost-reduction on the power-supply system. To elevate this reliability, several environmental tests have been created as qualification and certification procedures. This paper gives an overview about recent researches of reliability tests for Si photovoltaic modules.

추적식 수상 태양광 발전 시스템 성능 분석 (The Efficiency Analysis of Tracking-Type Floating PV System)

  • 양연원;정선옥;신현우;이길송
    • Current Photovoltaic Research
    • /
    • 제1권2호
    • /
    • pp.122-125
    • /
    • 2013
  • The Floating Photovoltaic System was installed on the surface of water. There were some researches in this subject. But there was not many studies with experiment on a high waterproof Floating Photovoltaic modules. The aim of this study was to analyze the performance of the Floating Photovoltaic System. For this experiment, a high waterproof Floating Photovoltaic modules were designed and applied to the module capacity of 10 kW Tracking-Type structure. The experiment results indicated the performance of the daily production is 51.6 kW; the production capacity of Floating Photovoltaic System is expected to be 23% higher than that of the ground-mounted photovoltaic system.

자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석 (Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose)

  • 이송은;배준학;신재원;전찬욱
    • Current Photovoltaic Research
    • /
    • 제6권3호
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

다결정 실리콘 태양광 모듈의 옥외 성능 평가 (Outdoor Performance Evaluation of Multi-Crystalline Silicon Photovoltaic Module)

  • 이유리;김우경;정재학
    • Current Photovoltaic Research
    • /
    • 제7권3호
    • /
    • pp.71-75
    • /
    • 2019
  • Solar energy is one of the renewable energy sources. It can respond to expanding energy demand. A solar cell module is designed to have a durability that can be developed over a long period of 25 years to be installed outdoors and perform like a stable power supply. We need Standard Test Condition (STC)-based power output data before and after testing to measure the power output of existing modules. The modules are shown to reduce power output by comparing data before and after outdoor experiments regardless of whether they are indoor or outdoor. It is easy to compare the power output quantities through the module simulator in the indoor. However, it takes a lot of testing time and costs to compare the power output on outdoor in the case of a high number of modules and distance from the module simulator. It can save time and costs if we can check the power output using the data in outdoor. We have used the long-term outdoor test to find the elements out that corresponds to the reductions in power output quantities. We have conducted research that matched the actual and the tests.

태양광발전시스템의 장기운전에 의한 성능특성 분석 (The Long-term Operating Evaluation of the Grid Connected Photovoltaic System)

  • 김의환;강승원;김재언
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.

BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석 (A study on the performance of various BIPV modules applied in a real building demonstration)

  • 이상문;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.53-63
    • /
    • 2016
  • Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of $45^{\circ}$ is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.

DC-DC 컨버어터에 의한 태양광 발전 시스템에 관한 연구 (A Study on Photovoltaic Generation System by DC-DC converter)

  • 원충연;양승호;김학성;김세찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.486-491
    • /
    • 1991
  • The photovoltaic modules have each maximum power point, which depending on the intensity of sunlight, modules temperature and etc. Cuk converter is used to obtain the maximum charging power from photovoltaic modules to storage batteries. This paper proposed to a new tracking control method by detecting its current and voltage in photovoltaic power generation system controlled by microprocessor, in order to operate at the maximum power point tracking(MPPT) even if the sunlight and the temperature are varied.

  • PDF

투명 백 시트와 봉지재 물질 조합에 따른 소형 슁글드 실리콘 태양전지 모듈의 열화 특성 분석 (Degradation Characteristics according to Encapsulant Materials Combining with Transparent Backsheet on the Mini Shingled Si Photovoltaic Modules)

  • 손형진;김성현
    • Current Photovoltaic Research
    • /
    • 제8권1호
    • /
    • pp.12-16
    • /
    • 2020
  • This study investigates the degradation characteristics of different material types of ethyl vinyl acetate (EVA) and polyolefin (POE) with combining transparent backsheet. To this end, we fabricated samples with structure of glass/encapsulant/transparent backsheet for each type of encapsulants, and shingled Si modules with the same structure. The samples were then subjected to accelerated test by storing under damp heat condition of 85℃ and 85% RH. As a result, encaplsulant discoloration was observed, which the transmittance of the samples with EVA decreased in a rapid rate than the samples with POE. The discoloration also affected a power degradation of the shingled modules with a reduction of current density, resulting that the module with EVA showed more drop on the efficiency than the modules with POE. Furthermore, corrosion of the soldered ribbon caused by acetic acid produced from the degraded EVA also contributed in fill factor reduction.

Performance Ratio of Crystalline Si and Triple Junction a-Si Thin Film Photovoltaic Modules for the Application to BIPVs

  • Cha, Hae-Lim;Ko, Jae-Woo;Lim, Jong-Rok;Kim, David-Kwangsoon;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.30-34
    • /
    • 2017
  • The building integrated photovoltaic system (BIPV) attracts attention with regard to the future of the photovoltaic (PV) industry. It is because one of the promising national and civilian projects in the country. Since land area is limited, there is considerable interest in BIPV systems with a variety of angles and shapes of PV panels. It is therefore expected to be one of the major fields for the PV industry in the future. Since the irradiation is different from each installation angle, the output can be predicted by the angles. This is critical for a PV system to be operated at maximum power and use an efficient design. The development characteristics of tilted angles based on data results obtained via long-term monitoring need to be analyzed. The ratio of the theoretically available and actual outputs is compared with the installation angles of each PV module to provide a suitable PV system for the user.