• 제목/요약/키워드: Photovoltaic current

검색결과 971건 처리시간 0.029초

고주파 절연 모듈형 Photovoltaic PCS (Modular Photovoltaic PCS with High-frequency Isolation)

  • 권정민;권봉환
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.11-18
    • /
    • 2005
  • A modular photovoltaic PCS with high-frequency isolation is proposed. The proposed system consists of a SEPIC converter and a full-bridge inverter Using the power slope versus voltage of the PV array, the MPPT controller is proposed that produces a smooth transition to the maximum power point. The dc current of the PV array is estimated without using a dc current sensor The disturbance of the line voltage is detected using a fast sensing technique. Experimental results obtained on a 500W prototype show high performance such as almost unity power factor, $90\%$ power efficiency, $3.6\%$ THD.

  • PDF

Efficiency of Photovoltaic Cell with Random Textured Anti Glare (RTAG) Glass

  • Kim, Geon Ho;Jeon, Bup Ju
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.133-137
    • /
    • 2016
  • The surface treatment of cover glass for conversion efficiency of photovoltaic cell is important to reduce reflectivity and to increase the incident light. In this work, random textured anti glare (RTAG) glass was prepared by wet surface coating method. Optical properties due to the changes of surface morphology of RTAG glass were compared and conversion efficiency of photovoltaic cell was researched. Grain size and changes of surface morphologies formed with surface etching time greatly affected optical transmittance and transmission haze. Current density (Jsc) were high at the condition when surface morphologies reflection haze were low and transmission haze were high. Jsc was $40.0mA/cm^2$ at glancing angle of $90^{\circ}$. Incidence light source was strongly influenced by surface treatment of cover glass at high incidence angle but was hardly affected light source at the low angle of incidence.

계통연계형 태양광 발전시스템의 운전특성 해석과 문제점 분석 (The Construction and Operating Characteristics analysis of Utility interactive PV power generation system)

  • 홍두성;고강훈;고희석;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.334-336
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller PLL control system and the phase detector of interactive voltage by using do transformation. The proposed inverter system provides a sinusoidal are current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

PWM 전류형인버터를 이용한 계통연계형 태양광 발전시스템 (Utility Interactive Photovoltaic Generation System using PWM Current Source Inverter)

  • 박춘우;성낙규;이승환;강승욱;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.109-112
    • /
    • 1996
  • In this paper, we composed utility interactive photovoltaic generation system of current source inverter, and controlled that low harmonic and high power factor are hold by supposing control and compensation method which is concerned with synchronous signal distortion and modulation delay. And we put parallel resonant circuit into dc link, so, magnitude of direct reactance was reduce by restraining direct current pulsation which had accumulation of pulsating power in alternating electrolytic condenser. Also we controlled that modulation factor is operated around maximum output of solar cell.

  • PDF

대면적 양면 태양광 모듈의 기계적 신뢰성 연구 (A Study on the Mechanical Reliability of Large-area Bi-facial Glass-to-glass Photovoltaic Modules)

  • 노요한;유장원;이재형
    • Current Photovoltaic Research
    • /
    • 제10권4호
    • /
    • pp.111-115
    • /
    • 2022
  • For the high efficiency of the photovoltaic module, a high-output solar cell, which is the basis of photovoltaic power generation, is required. As the light receiving area of the solar cell increases, the light receiving area of the photovoltaic module also increases. Accordingly, recent trend is to use large-area solar cells such as M6 and M8 instead of M2-based solar cells for manufacturing the photovoltaic module and a study on the mechanical stiffness of the module with increased size is required. In this study, a mechanical load test corresponding to IEC-61215 was performed among the reliability tests of large-area photovoltaic modules. In order to confirm the degree to which the mechanical load test affects the photovoltaic module, the output and EL images were checked by sequentially increasing the pressure by 600 Pa at a pressure of 2400 Pa. Also, factors such as output and efficiency of large-area photovoltaic modules were verified through mechanical load testing of actual large-area photovoltaic modules and the rate of change was very small at 1%.

무회전축 회전식 수상태양광 시스템 및 실증 데이터 분석 (The Pivotless Tracking Type Floating Photovoltaic System and the Collected Data Analysis)

  • 지홍섭;김민우;배재성;정정호;이재형
    • Current Photovoltaic Research
    • /
    • 제9권4호
    • /
    • pp.133-136
    • /
    • 2021
  • In this study, the pivotless tracking type floating photovoltaic system was demonstrated successfully. The photovoltaic modules were installed on buoyant objects and the dynamic stability reinforcement mooring gear, tension control equipment and buoyant stabilizer were used to provide enough buoyance and stability and response to the external environment. After installation of the pivotless tracking type floating photovoltaic system, generated solar energy was collected and analyzed.

태양광 인버터 회로구조에 따른 누설전류 비교 (Comparison of Leakage Current in Various Photovoltaic Inverter Topologies)

  • 윤한종;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.105-106
    • /
    • 2016
  • In low-power grid-connected photovoltaic(PV) system, Single-phase transformerless full-bridge inverter is commonly used. However in transformerless photovoltaic application, the ground parasitic capacitance created by grounding between PV panels and ground. This ground parasitic capacitance inject additional current into the inverter, these currents cause electromagnetic interference problem, safety problem and harmonics problem in PV applications. In order to eliminate the ground current, This paper propose various inverter topologies in PV applications. These proposed inverter topologies are verified through simulation using PSIM.

  • PDF

단일 센서를 사용한 태양광 Module Integrated Converter의 최대전력점 추종 기법 (A Novel MPPT using Single Sensor for Photovoltaic Module Integrated Converter)

  • 지용혁;김영호;정두용;이수원;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.263-266
    • /
    • 2009
  • In the photovoltaic applications, MPPT(maximum power point tracking) method is essential due to the non-lineality of photovoltaic output characteristics. To ensure stable tracking response, two sensors are required in conventional popular MPPTs. In modularized PV system as an AC module system, the cost of a sensor can have an effect on entire system cost because a power conditioning device is connected in a PV module. Because only a current sensor is required for proposed MPPT, it is helpful in the cost reduction point of view. In this paper, a novel MPPT using current sensor is proposed In the proposed MPPT, the voltage is derived from sensed current value. The proposed method is verified by simulation results.

  • PDF

Effects of Carrier Mobility on Photocurrent Generation in $TiO_2/Poly$(alkylthiophene) Photovoltaic Devices

  • Song, Mi-Yeon;Kim, Kang-Jin;Kim, Dong-Young
    • Macromolecular Research
    • /
    • 제14권6호
    • /
    • pp.630-633
    • /
    • 2006
  • In heterojunction photovoltaic devices of $ITO/TiO_2/poly$(3-alkylthiophene)/Au, the photo current was characterized at different temperatures for different alkyl chain lengths and regioregularities: regiorandom, regioregular poly(3-hexylthiophene), and regioregular poly(3-dodecylthiophene). The regioregularity and alkyl chain length affected the photovoltaic characteristics due to differences in hole-carrier transportation. The drift charge mobilities of these devices were analyzed by the space-charge-limited current theory using the relation between the dark current and the bias voltage. The photocurrent in the devices based on poly(3-alkylthiophene)s decreased rapidly below the temperature at which the drift charge mobility was $10^{-5}\;cm^2/V{\cdot}s$.