• Title/Summary/Keyword: Photovoltaic array (PV)

Search Result 188, Processing Time 0.027 seconds

Transformer-less Type Grid-Connected PV Power Conditioning System (변압기 없는 계통연계형 PV PCS고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.

Research and Experimental Implementation of a CV-FOINC Algorithm Using MPPT for PV Power System

  • Arulmurugan, R.;Venkatesan, T.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1389-1399
    • /
    • 2015
  • This research suggests maximum power point tracking (MPPT) for the solar photovoltaic (PV) power scheme using a new constant voltage (CV) fractional order incremental conductance (FOINC) algorithm. The PV panel has low transformation efficiency and power output of PV panel depends on the change in weather conditions. Possible extracting power can be raised to a battery load utilizing a MPPT algorithm. Among all the MPPT strategies, the incremental conductance (INC) algorithm is mostly employed due to easy implementation, less fluctuations and faster tracking, which is not only has the merits of INC, fractional order can deliver a dynamic mathematical modelling to define non-linear physiognomies. CV-FOINC variation as dynamic variable is exploited to regulate the PV power toward the peak operating point. For a lesser scale photovoltaic conversion scheme, the suggested technique is validated by simulation with dissimilar operating conditions. Contributions are made in numerous aspects of the entire system, including new control algorithm design, system simulation, converter design, programming into simulation environment and experimental setup. The results confirm that the small tracking period and practicality in tracking of photovoltaic array.

A Photovoltaic Device Model for Grid-connected PV System Simulation (계통연계형 태양광발전시스템의 태양광전지모델 시뮬레이션)

  • Campbell, Ryan;Kim, Hak-Man;Lee, Jong-Su;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.18-19
    • /
    • 2006
  • The recent interest in distributed generation (DG) due to the opening of the electricity market and the need for alternatives to conventional fossil fuel-based electricity generation has created renewed interest in grid-connected photovoltaic(PV) systems. Many studies are being performed at the power system level to examine the impacts of grid-connected PV systems and several models for PV arrays have been proposed in the literature. However, the complexity of these models and difficulties of implementing them in various software programs can be deterrents to their use. This paper proposes a robust and flexible PV device model suitable for dynamic and transient studies where the PV array's non-linear DC characteristics are important. The model's implementation in software is straightforward and it can even be constructed using standard software library components, as demonstrated using PSCAD/EMTDC.

  • PDF

A modeling and performance comparison of photovoltaic module (태양광모듈의 모델링 및 성능해석 결과비교)

  • So, Jung-Hun;Yu, Byung-Gyu;Hwang, Hye-Mi;Yu, Gwon-Jong;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1128-1129
    • /
    • 2008
  • The detailed modeling method of photovoltaic (PV) module are useful to perform detailed analysis of PV array performance for changing meteorological conditions, verify actual rated power of PV system sizing and, determine the optimal design of PV system and components. This paper investigates a modeling approach of PV module performance in terms of irradiance and temperature changes and compared measured with simulated value of PV modules.

  • PDF

A study on advanced PV operation algorithm to improve the PV Power-Hardware-In-Loop Simulator (PV PHIL-시뮬레이터의 성능 개선을 위한 최적의 운영제어 알고리즘 연구)

  • Kim, Dae-Jin;Kim, Byungki;Ko, Hee-Sang;Jang, Moon-Seok;Ryu, Kyung-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.444-453
    • /
    • 2017
  • This paper proposes an operational algorithm for a Photovoltaic Power-Hardware-In-Loop Simulator that is designed to improve the control algorithm and reliability of the PV Inverter. There was an instability problem in the PV PHILS with the conventional algorithm when it was connected tothe PV inverter. Initially, a real-time based computing unit with mathematical modeling of the PV array is implemented and a DC amplifier and an isolated device for DC power measurement are integrated. Several experiments were performed based on theabove concept undercertain conditions, which showed that the proposed algorithm is more effective for the PV characteristic test and grid evaluation test than the conventional method.

Comparison of maximum generated power by shading effect and PV array configurations (그림자 영향과 태양광 어레이 구조에 따른 최대발생전력 비교 해석 및 실험)

  • Kim, Eui-Jong;Yu, Byung-Gyu;Cha, Han-Ju;Yu, Gwon-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.8-13
    • /
    • 2009
  • In this paper, two configurations of PV array are analyzed and tested under shading condition, where two configurations are series-parallel and total-crass-tied configuration. Each photovoltaic module is emulated by two 5 inch po1y-crystalline cells in series and an array is constructed by connecting 24 of the modules to compare a generated maximum power of the two configurations. Pspice and Sun simulator. PASAN IIIb, are used for simulation and experiment to test the array under various partial shading conditions. Test results show the total-cross-tied configuration generates 7.63% higher maximum power than the series-parallel configuration, and it is well matched to the analysis and simulations of the two configurations.

A Study on the Economic Evaluation of Photovoltaic System in the Residential Building (주거용 건물의 태양광 발전시스템 경제성 평가에 관한 연구)

  • Choi, Jeong-Min;Ju, Jai-Wook;Kim, Dong-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.14-21
    • /
    • 2009
  • The demand and installation for photovoltaic system(namely, PV) has grown steadily in Korea. However, the PV system has a various economic viability according to the PV system characteristic variables such as inverter efficiency, miscellaneous power conditioning losses, azimuth and slope of PV array, PV tracking mode, and so on. The other variables are the monthly consumed electric energy and economic related factor such as initial cost, government subsidy, maintenance cost, inflation rate, energy cost escalation rate, discount rate, etc. Therefore, this study is to present economic evaluation of PV system with those concerned factors by calculating internal rate of return, year-to-positive cash flow and net present value indices.

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise (고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터)

  • Lee, Sung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.