• 제목/요약/키워드: Photovoltaic array

검색결과 289건 처리시간 0.027초

Tracking Control of Maximum Power Point of Photovoltaic Array by using the Microprocessor (Microprocessor를 이용한 태양전지의 최대 출력점 추적 제어)

  • Han, K.H.;Jang, K.H.;Kwon, H.;Kim, D.K.;Lee, W.K.;Kang, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.492-495
    • /
    • 1991
  • This paper proposes the microprocessor-based step-up chopper system used for the battery charge from the photovoltaic arrays. The proposed scheme tracks the maximum power point by analyzing the voltage and power phasors which vary as the solar irradiation quantity. In this system, protection for the overcharge and overdischarge in also provided.

  • PDF

FPGA based POS MPPT control for a small scale charging system of PV-nickel metal hydride battery (FPGA를 이용한 소형 태양광 발전 니켈 수소 전지 충전 시스템의 POS MPPT 제어)

  • Lee, Hyo-Geun;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1306-1307
    • /
    • 2011
  • Recently, the small scale photovoltaic (PV) electronic devices are drawing attention as the upcoming PV generation system. The PV system is commonly used in small scale PV applications such as LED lighting and cell phone. This paper proposes photovoltaic output sensorless (POS) maximum power point tracking (MPPT) control for a small scale charging system of PV-nickel metal hydride battery using field-programmable gate array (FPGA) controller. A converter is connected to a small scale PV cell and battery, and performs the POS MPPT at the battery terminal current instead of being at the PV cell output voltage and current. The FPGA controller and converter operate based on POS MPPT method. The experimental results show that the nickel metal hydride battery is charged by the maximum PV output power.

  • PDF

Analysis of analog MPPT Algorithms for Low cost Photovoltaic System (저가형 태양광 발전시스템을 위한 아날로그 MPPT 알고리즘의 특성 해석)

  • Kim Han-Goo;Lee Sang-Yong;Choi Moon-Gyu;Kim Hong-Sung;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.121-124
    • /
    • 2004
  • In this paper, Simple and inexpensive analog maximum power point tracker (MPPT) algorithm for photovoltaic power system and low power system of doesn't use digital signal processor (DSP). The control circuit is composed such that the actual current and voltage are sensed directly from the PV array. These two signals are then multiplied by a single-chip multiplier. The multiplier output go through different time constants genesis pulse width modulated to switch. Finally those were verified through simulation.

  • PDF

Grid-Connected Photovoltaic Inverter with Zero-Current-Switching (영전류 스위칭 계통 연계형 태양광 발전 인버터)

  • Choi, Hang-Seok;Kim, J.D.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.953-955
    • /
    • 2001
  • This paper presents a new zero current switching (ZCS) inverter for grid-connected photovoltaic single phase inverter system. The auxiliaey circuit for the soft-switching consists of two resonant inductors and two resonant capacitors as well as two auxiliary switches rated at lower power. The proposed circuit provides zero current switching condition for all the switches, which reduces switching losses significantly. It is controlled to extract maximum power from the solar array and to provide sinusoidal current into the mains. The validity of the proposed system is verified by experimental results from the 1.2kW prototype inverter operating at 40kHz.

  • PDF

A Photovoltaic Device Model for Grid-connected PV System Simulation (계통연계형 태양광발전시스템의 태양광전지모델 시뮬레이션)

  • Campbell, Ryan;Kim, Hak-Man;Lee, Jong-Su;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.18-19
    • /
    • 2006
  • The recent interest in distributed generation (DG) due to the opening of the electricity market and the need for alternatives to conventional fossil fuel-based electricity generation has created renewed interest in grid-connected photovoltaic(PV) systems. Many studies are being performed at the power system level to examine the impacts of grid-connected PV systems and several models for PV arrays have been proposed in the literature. However, the complexity of these models and difficulties of implementing them in various software programs can be deterrents to their use. This paper proposes a robust and flexible PV device model suitable for dynamic and transient studies where the PV array's non-linear DC characteristics are important. The model's implementation in software is straightforward and it can even be constructed using standard software library components, as demonstrated using PSCAD/EMTDC.

  • PDF

A Study on optimal design for installion of 500kWp PV system testing ground (500kW급 태양광시험장 구축을 위한 최적설계에 관한연구)

  • Kim, Eui-Hwan;Jang, Ju-Yeon;Lim, Hee-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • 제30권4호
    • /
    • pp.43-48
    • /
    • 2010
  • The performance of photovoltaic systems could be affected by various factors including installing conditions of modules, and their own efficiencies of solar cells and inverters. The installing conditions of a photovoltaic system including array types, tilting angles, azimuth, locations, quantities of sunshine, optimum angles of inclination and separated distance are analyzed using the SolarPro & Minitep SW simulation program, inorder to set up the installing conditions for improving system performance. The result from the simulation of the 500kWp PV system of Kochang with optimal installing conditions compared with normal conditions shows that the capacity factor has been increased from 11.02% to 12.06%.

Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise (고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터)

  • Lee, Sung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

The MPPT of Photovoltaic Solar System by Controlled Boost Converter with Neural Network

  • Cha, In-Su;Lim, Jung-Yeol;Yu, Gwon-Jong
    • Journal of IKEEE
    • /
    • 제2권2호
    • /
    • pp.255-262
    • /
    • 1998
  • The neural network can roughly be classified as the specialized control, indirect control and general schemes. Neural network is adopted for MPPT of solar array. And back propagation algorithm also is used to train neural network controller. We investigate the possibilities of $P_{max}$ control using the neural networks, and then we also examine about operating the solar cell at an optimal voltage comprise of temperature compensated voltage with boost converter. Proposed boost converter of MPPT system is studied by simulation and is implemented by using a microprocessor(80c196kc) which controls duty ratio of the boost converter.

  • PDF

The Improved Maximum Power Point Tracking Algorithm under varying of irradiance (일사량 변화를 고려한 개선된 MPPT 알고리즘)

  • Lee, Gwui-Han;Jung, Young-Seok;Lee, Youn-Seop;Cha, Han-Ju;KO, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • 제35권6호
    • /
    • pp.17-24
    • /
    • 2015
  • The MPPT(Maximum Power Point Tracking) techniques are employed in photovoltaic (PV) systems to maximize the PV array output power which depends on solar irradiance and temperature. The dynamic MPPT performance under varying irradiance conditions affects the impact on overall PV system performance. This paper presents the improved MPPT algorithm by the simulation comparison with other algorithms. The simulation models are made by the Matlab & Simulink. The result of simulation, the dynamic MPPT efficiency of proposed algorithm is higher than the other algorithms.

Single-Phase PCS with UPS Function Based on Dc Bus Oriented Control (dc bus 중심 제어를 이용한 UPS 기능을 갖는 단상 태양광 발전 시스템)

  • Kim, Eung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2007
  • 본 논문에서는 UPS 기능을 갖는 단상 태양광 발전 시스템을 제안하였다. 제안하는 시스템은 태양광 어레이 (photovoltaic array)에서 최대전력을 얻기 위해 MPPT (maximum power point tracking)를 수행하는 컨버터, 계통전원 상태나 태양광 발전량에 상관없이 부하에 정현파 전압을 공급하는 인버터, 태양광 어레이에서 발전된 잉여전력을 계통으로 전달하거나 부하에 필요한 전력을 dc bus로 공급하는 인버터, 정전시 dc bus에 전력을 공급하는 양방향 컨버터 (bidirectional converter)로 구성된다. 제안하는 시스템은 발전된 전력을 계통으로 전달할 뿐만 아니라, UPS (uninterruptible power supply)기능도 수행하는 시스템으로 계통전압이 불안정하거나 정전시에도 부하에 안정적이고 깨끗한 전압을 항상 공급할 수 있다. 각각의 인버터, 컨버터, 및 양방향 컨버터는 dc bus를 공유하며, dc bus의 전압에 따라 동작상태가 결정이 된다. dc bus중심의 제어는 dc bus전압을 안정적으로 유지시키며, 부하에 걸리는 전압의 변동을 최소로 하고 시스템의 디자인 및 제어를 단순화한다. 모든 알고리즘과 제어기를 하나의 마이크로 컨트롤러로 구현하였고 제안된 시스템의 우수성을 실험을 통해 검증하였다.

  • PDF